Medical combined refrigerator & freezer (22 pages)
Summary of Contents for Vacc-Safe VS -25L Series
Page 1
Product implementation standards EN 61010-1 :2010/A1:2019 EN 61010-2-011:2017 EN 61326-1 :2013 USER MANUAL Biomedical VS-25L518 MODEL: VS-30L518 VS-40L518...
Efficient Refrigeration Energy Saving Mute • Vacc-Safe is a world-renowned compressor brand that focuses on energy saving, environmental protection, high efficiency and noise suppression. • Stable and long-lasting performance, low noise, more uniform and stable...
Precautions and Safety Measures Dear users of Vacc-Safe: Hi! Thank you for using Vacc-Safe medical freezer. For your convenience to understand this manual, use the product, and prevent personal injuries and goods damages, please read the following instructions thoroughly. Failure in complying matters highlighted in...
Page 5
The power cord of this freezer is equipped with a three-wire (grounded) plug, which meets the standard three-wire (grounded) socket of 10 A. Under no circumstances should the grounding pin of the power cord be removed. Make sure that the power plug and socket are plugged firmly and reliably, otherwise it may lead to fires.
Page 6
Don't use the freezer in the open air. When the freezer is wet by rain, it may cause electric leakage or electric shock. Freezers should not be placed in damp places or places vulnerable to splashing water. Otherwise, electric leakage or electric shock will be caused due to insulation reduction.
Page 7
When transporting the freezer, be careful not to trip over freezer to prevent damage to freezer or personal injury. Please do not use the door handle to lift or carry the equipment, in case of injury to the freezer or personal injury. The refrigeration circuit must not be damaged.
Precautions for Use Before putting articles into the equipment, please make sure that the temperature in the storage room has reached the set temperature, and then put the articles in batches. The volume of the articles in the box should not exceed 1/3 of its volume at a time to prevent the temperature from rising too much.
Product Installation Installation environment -------------------------------------------- The freezer is only for indoor use, with second pollution level and second type of over-voltage Ambient temperature is within 16°C-32°C, and recommended temperature is within 18°C-25°C. If necessary, air conditioning system should be used. Environmental humidity: lower than 80%Rh.
Page 10
Device should be reliably grounded. If the power outlet is equipped with grounding wire, check whether it is normal before use. If the power outlet is not grounded, the grounded wire must be installed by professional technicians. Warning Do not ground the freezer through gas pipe, power supply pipe, telephone line or lightning rod.
Page 11
First Power On ----------------------------------------------------------- When using the device for the first time, please follow these steps: 1. After the device is placed, leveled and cleaned, it needs to be left for more than 24 hours before it is connected to the power supply to ensure the normal operation of the device.
Page 12
• This product is a medical freezer VS -25L Series Temperature of the freezer ranges from -10~-25°C and is adjustable VS -30L Series Temperature of the freezer ranges from -10~-30°C and...
Product Composition and Overview Display control panel Door Door handle Door lock Universal casters * Due to the improvement of products and different models, the actual products may be different from the schematic drawings. Please refer to the real objects! The sketch is only used for the description of the functional parts.
Operating Instructions Operation and Display Panel Alarm Door Open Set / Mute Temperature+ Temperature- Print Function Introduction Temperature display window: under normal operation, the upper chamber temperature and lower chamber temperature are displayed respectively in °C. Door-opening indicator: the indicator lights up when the upper or lower chamber door is open.
Page 15
Increase the parameter value in the parameter setting mode. For example, increase the set temperature when setting the set temperature. Press and hold key when setting the parameter value, the parameter can be increased quickly. Setting / Mute key: when there is no alarm state and the key is not unlocked, press down the key, the normal display resumes after displaying the ambient temperature for 5 seconds.
Page 16
Manual export of USB data: when the key is unlocked and no file is being generated, connect the USB flash disk and press the key for 3s until the digital tube displays "d01". Press the key to adjust "d00~d12". Press the key, and the file generated this time (d00) or the PDF file with the data recorded in the forward month (1-12) is cancelled inside the USB flash disk.
Press the key to switch parameters n-y-r-s-F-Pt-SCY Press the key or the key to set the parameter value. After setting, press and hold to save the parameter. Note: Operation to modify the time and recording interval will cause the recorder data to be cleared, and the data recorder will be restarted.
Page 18
1. Scroll through the parameters using the key, and the display order is MAX1 -MIN1-MAX2-MIN2-CLR-SEt1- H01-L01-SEt2-H02-L02-n-y-r-S-F-Pt-tH1-P1- PS1-b1-b2 2. Increase or decrease the value using the keys; 3. Press the key to temporarily store the modified value and return to the display parameters 4.
Page 19
Serial Parameter Recommended Menu Note Number Range Setting Value Check the current date - year Check the current date - month Check the current date - day Check the current date - hour Check the current date - minute 0~240 Printing interval minutes 20.0~50.0...
Page 20
Fault Alarm Code: Alarm Code Fault Description High temperature alarm of the upper chamber Low temperature alarm of the upper chamber High temperature alarm of the lower chamber Low temperature alarm of the lower chamber High ambient temperature alarm door 1 Door-opening alarm of the upper chamber door 2 Door-opening alarm of the lower chamber...
Page 21
Maintenance and Care Warning To prevent electric shock or personal injuries, please make sure that power is disconnected before having any repairs or maintenance on the device. When maintaining the device, make sure that you do not inhale surrounding medications or suspended particles that could damage your health. Note Do not directly sprinkle water on the freezer, so as to avoid the decline of insulation performance of electrical components and rust of metal parts.
When there is a failure in the product, please check and handle it according to the following table. If the situation cannot be changed, please inform Vacc-Safe Biological Service Center in time. We will serve you wholeheartedly to avoid any loss to you.
Page 23
Malfunction Troubleshooting Whether too many or overheated items are stored Whether there is a certain gap between the stored items The cooling effect is not obvious, and Whether there is direct sunlight or other heat source the temperature radiation exceeds the Whether the door is open frequently standards Whether the ambient temperature is too high...
Speci cations Name Medical Low-Temperature Freezer Model number VS-25L518/VS-30L518/VS-40L518 External dimensions 866*811*1920 The upper chamber: 680*620*650 Internal dimensions The lower chamber: 680*620*650 E ective volume The upper chamber 259L The lower chamber 259L The upper chamber: Foaming door Door body The lower chamber: Foaming door Foamer Cyclopentane...
Packing List Model Instruction Door Handle Number VS-25L518 VS-30L518 VS-40L518 The warranty card and certi cate are included in the instruction and the speci c packing list shall prevail in accordance with the real product. Electrical Schematic Diagram Control panel Display panel Adapter...
Conditions of free warranty 1 They should be the users who have purchased Vacc-Safe medical freezer series products and have gone through warranty registration procedures. 2 The warranty certificate (warranty card) should be held and the name, model number, bar code of the product to be repaired must be consistent with those on the warranty card;...
Page 27
Product warranty period Whole Main Note Machine Components The main components include: compressor, main control panel, display control panel, temperature controller, Two years Two years evaporator, condenser, solenoid valve, filter, capillary, fan motor. (Note: if there are a separate warranty agreement, it shall be performed based on the agreement)
Need help?
Do you have a question about the VS -25L Series and is the answer not in the manual?
Questions and answers