Signal controller for brushless screwdriver (12 pages)
Summary of Contents for Sumake SMT-C1
Page 1
OPERATION AND MAINTENANCE MANUAL SMT-C1 ITEM NO.: SMT-C1B SMART CONTROLLERS ARE COMPATIBLE WITH SMT TRANSDUCERIZED DC ELECTRIC SCREWDRIVERS SMT-C1(B)-I-2309K-K2...
External output control function description .................. 10 External input control function description ..................11 Data transmission description and flow control suggestion ............12 Please download the DAS software from the SUMAKE website to enable parameter setup and modification on your computer (PC or laptop) https://www.sumake.com/cate-341516.htm...
1. Product specification introduction Model SMT-C1 SMT-C1B Input Voltage AC 115V / 230V Input Frequency 50 - 60Hz Input Current 6.3A Input Voltage DC 40V Output Current Max 9A Output Power 360W Function Period 1s ON / 3s OFF Size...
2. Appearance introduction 2.1 Panel OK signal LED 7. Start signal LED NG signal LED 8. Reverse signal LED OKALL signal LED 9. Disable signal LED 10. 16X4 LCM display setting function Four-digit-seven-segment display for torque value 11. Enter button (Select/Confirm) ESC button (Return/Leave/Enter setting mode) Up、Down、Left、Right buttons...
2.2 Bottom Micro SD card slot (Data Storage) Voltage Choice Switch External wireless module port Barcode scanner USB type-A port Software update port Wired communication port Tool connector Output signal port Socket and switch Input control signal port 2.3 Upper case 1.DC fuse station (Content 10A/250V) 2.Grounding station (FG)
4. Control setting Name Set Up Time Function Description Default setting and Value Operation mode STD/ADV Connection mode. STD: Standalone mode. ADV: EAA-AMS network system. (STD/ADV) connection mode. Device ID 001~250 Equipment No. Tool Start Mode Both/Push/Lever Choose tool start mode. Lever Tool LED Mode START/ON/OFF...
Controller Time YYYY/MM/DD Set up controller time 2018/01/01 Year/Month/Day/Hour/Minute/Second. HH:MM:SS 01:01:01 Product Serial Number Display device product serial number. Change Password 0000~9999 Set up password lock 0000 Output Select WIFI/LAN/RS-232 Select data output from offline RS-232 to online Buzzer Mode ON/OFF Setup buzzer.
6. Screw setting Set Up Default Name Function Description Value setting Tightening Program 01~99 Setup screw parameter. Screw Name ****** Setup screw parameter name. It can choose ****** number、capitals and lower case letters、number. Step 1 001~250 Setup 1 sequence Step 2 000~250 Setup 2 sequence...
8. CONFIRM mode Code Description Disable method External GATE Signal Once external confirmation “GATE” Trigger once External GATE Signal Twice external confirmation “GATE” Trigger twice When『OKALL disable screwdriver』function is on, LCM Panel Enter button/ External CONFIRM will display『C3』after a batch completed. External GATE Signal When 『OKALL disable screwdriver』...
Screwdriver end communication error:When the electric screwdriver communication error occurs, the electric screwdriver will be stopped and the LCM displays this ES. Calibration is required when EOC is stated on LCM display. [Note]: When numbers of tightening are reached one million time, the EOC warning comes up on display panel each time as machine turning on.
10. External input control function description Connector No Symbol Definition Function Description External start 1. When CN1+CN2 short (CLOSE), screwdriver CN 1 signal input start functioning. START_IN 2. When CN1+CN2 open (OPEN),screwdriver stop CN 2 functioning. 1.When external reverse signal CN3+CN4 short External reverses (CLOSE) first and activate signal CN1+CN2 short (CLOSE), CN 3...
11. SMT-C1(B) Data transmission description and flow control suggestion 1. Controller power on and time synchronization After controller is power on, it will send data {REQ100...} each second to inform external device such as computer、PLC、AMS. The external device needs to reply {CMD100,..} that to sync the external device time to the controller.
Page 14
Ethernet Cyclic communication Controller send to external device Controller External device REQ100(send/sec.) SMT-C1(B) PC/AMS/PLC External device response to controller (Master) (Slave) CMD100(send/sec.) Get Barcode Data External device Controller Barcode data from the controller REQ101 PC/AMS/PLC SMT-C1(B) External device response to controller...
Page 15
EU Declaration of Conformity (DOC) SUMAKE INDUSTRIAL CO., LTD. 4F, No. 351, Yangguang St., Neihu District, Taipei City, Taiwan declare in sole responsibility that the equipment Equipment: POWER SUPPLY (SMART CONTROLLER) Model/ Serial No.: SMT-C1, SMT-C1B The object of the declaration described above is in conformity with the relevant union harmonization legislation: ...
Need help?
Do you have a question about the SMT-C1 and is the answer not in the manual?
Questions and answers