1. Before using the product, carefully review this user manual and keep it in a readily accessible location. 2. All information in this user manual, including images and symbols, is proprietary to PowMr. Unauthorized use of any part or all of the content is strictly prohibited for individuals outside the company.
2.3.2 Label Protection 1. The warning labels on the body of the POW-HVB series high-voltage energy storage units contain important information for the safe operation of the product. It is strictly prohibited to tear or damage them intentionally! 2.
Page 5
User Manual POW-HVB Series 2.3.3 Safety Warning Signs When installing, performing routine maintenance, or repairing POW-HVB series high-voltage energy storage products, to prevent unauthorized personnel from approaching, performing improper operations, or accidents, the following provisions should be adhered to: 1. Place prominent signs at the household energy storage product switches to prevent accidental closing causing accidents;...
Page 6
User Manual POW-HVB Series 2. Ensure correct and standardized electrical connections of the instruments to avoid dangers such as arcing. 2.3.7 Maintenance and Inspection 1. Both the energy storage battery and the inverter must be turned off, and the electrical connections confirmed to be disconnected before maintenance or inspection operations can be performed on the energy storage battery.
Page 7
User Manual POW-HVB Series 6. Do not damage any part of the battery, including internal and external components. 7. Do not directly connect the battery to a photovoltaic array. 8. Do not reverse the polarity! 9. Do not directly connect the battery to a wall outlet or car cigarette lighter! 10.
Page 8
User Manual POW-HVB Series 4. The stored battery power should not be less than 80%. After complete discharge, the battery needs to be recharged for at least 12 hours. 5. The self-discharge protection mode for safely storing lithium batteries follows the technical standards below: ⚫...
User Manual POW-HVB Series 3 Overview of Main Components Image Name Quantity Main Control box Battery Module Base Positive Power Cable Negative Power Cable Communication Box (Optional) Communication cable between battery pack and inverter (Compatible with SOLXPOW series) M8 Expansion Screw...
4.2 Product Features 1. The POW-HVB high-voltage energy storage series is a battery module developed by PowMr Energy suitable for high-voltage lithium battery systems, primarily used in residential or commercial energy storage fields; it achieves high-precision multi-cell voltage and temperature acquisition.
User Manual POW-HVB Series 10. Supports stacking of up to 5 battery modules in series, with battery voltage ranging from 204.8V (2 modules in series) to 512V (5 modules in series). Flexible configuration, with maximum energy storage capacity of up to 25KWh.
User Manual POW-HVB Series 4.4 Product Appearance Main Control Box LED Indication light Base Handle Battery Interconnection Power and Battery Module Communication Connection Ports...
User Manual POW-HVB Series 4.5 Main Control Box Connection Panel Name Function Remarks Connects to the positive pole of Power Port (+) the inverter battery port Connects to the negative pole of Power Port (-) the inverter battery port Communicates with the...
User Manual POW-HVB Series 5 Installation and Wiring 5.1 Pre-Installation Preparation 1. Tools Required: Phillips screwdriver, multimeter, insulated gloves, Ethernet cable, power cord, etc. 2. Unboxing: Remove the battery and other items from the packaging, first check the condition of the battery's exterior, and then verify the completeness of the accessories according to the parts list.
User Manual POW-HVB Series 5.3 Installing Battery Packs Warning: Due to the weight of the battery packs, exercise caution when removing them from the packaging or during installation. It is recommended to have two or more people handle the installation.
Page 17
User Manual POW-HVB Series Step 3. Place the battery module with the base against the wall, ensuring that the wall is perpendicular to the ground. (Note: The wall must be load-bearing; otherwise, the battery module cannot be installed on it.) Secure the mounting bracket to the battery using three screws.
Page 18
User Manual POW-HVB Series Step 5. Drill Ø8mm holes with a depth of approximately 60mm, spaced as shown below: (Install anchor bolts after drilling) Step 6. Align the dowel pins, place the second battery module on top of the first one, and secure the hooks with screws.
Page 19
User Manual POW-HVB Series Step 7. Finally, install the main control box to complete the installation. Refer to the illustration below: Step 8. Loosen one screw to open the side cover of the main control box, install the output cables and communication cables, and connect them to the inverter. Tighten the side...
User Manual POW-HVB Series 6 Operation and Debugging 6.1 Battery Startup 1. Start the battery using the power switch. 2. Once the battery indicator lights up, close the DC circuit breaker at the battery output terminal. 3. After the battery starts up, if there are no abnormal indications on the model indicator light on the front of the main control box, it indicates that the battery has started up normally.
User Manual POW-HVB Series 6.2.2 Indicator Light Display Explanation Indicator Light Status Explanation The green indicator light runs in sequence from low to high, completing the self-check and entering standby mode. For Startup Self-Check example, from light 1 to light 10. After completion, the charging and discharging functions are enabled.
User Manual POW-HVB Series 6.4 Upper Computer Communication and Debugging If you need to connect to the upper computer to perform related operations, please prepare the following items in advance: ⚫ Computer ⚫ Dedicated communication cable and communication box ⚫ Upper computer software Connect to the computer via the Debug CAN port.
User Manual POW-HVB Series 7 Common Issues and Solutions Specific Issue Possible Cause/Resolution 1. Ensure the battery switch is in the "ON" position. If the battery SOC is too low, charge the battery immediately. Battery not 2. Battery voltage is too low or the battery is in sleep mode.
Page 26
User Manual POW-HVB Series resetting and calibrating the BMS to ensure it accurately monitors and manages the battery pack's status. Recommended method: Reset the power switch, and then restart the BMS system. How to start the *Warning: Equipment operating parameters must not exceed the...
Need help?
Do you have a question about the POW-HVB Series and is the answer not in the manual?