User's Manual Foreword General This manual introduces the installation, functions and operations of the alarm repeater (hereinafter referred to as the "repeater"). Read carefully before using the device, and keep the manual safe for future reference. reference. Model DHI-ARA43-W2 (868); DHI-ARA43-W2. Safety Instructions The following signal words might appear in the manual.
Page 3
User's Manual Version Revision Content Release Time V1.1.0 Added app and hub versions. September 2021 V1.0.0 First release. August 2021 Privacy Protection Notice As the device user or data controller, you might collect the personal data of others such as their face, fingerprints, and license plate number.
User's Manual Important Safeguards and Warnings This section introduces content covering the proper handling of the repeater, hazard prevention, and prevention of property damage. Read carefully before using the repeater, and comply with the guidelines when using it. Operation Requirements Make sure that the power supply of the device works properly before use.
Page 5
User's Manual Observe all safety procedures and wear required protective equipment provided for your use ● while working at heights. Do not expose the PIR to direct sunlight or heat sources. ● Do not install the PIR in humid, dusty or smoky places. ●...
User's Manual 1 Introduction 1.1 Overview Alarm repeater is a wireless repeater device that extends the communication range between the alarm hub and other accessories, and forwards messages received from the accessory to the hub. It provides a secondary communication path for accessories, improving the overall stability and reliability of communication of the wireless security system.
Page 8
User's Manual Type Parameter Description DHI-ARA43-W2 (868): DHI-ARA43-W2: Communication Up to 1,600 m Up to 1,000 m (3280.84 ft) Distance (5249.34 ft) in an open in an open space space Communication Two-way Mechanism Encryption Mode AES128 Frequency Hopping PS Type Type A Main Power 12 VDC, 1.5 A...
Page 9
User's Manual Type Parameter Description 50131-1:2006+A2:201 7+A3:2020 EN 50131-3:2009 ● EN 50131-6:2017 ● EN 50131-5-3:2017 ● ● Certifications EN 50131-10:2014 ● ● EN 50136-2:2013 ● Security Grade 2 ● Environmental ● Class II ●...
User's Manual 3 Design 3.1 Appearance Figure 3-1 Appearance Table 3-1 Structure Name Description Solid green: Turned on. ● Indicator Flashes green: Pairing with the hub. ● Switch to ON to turn on the repeater, and OFF to turn it off. Power switch OFF is set by default.
User's Manual 4 Power on Procedure Step 1 Loosen the screw to open the repeater. Figure 4-1 Loosen the screw Figure 4-2 Open the repeater Step 2 Insert the wire into the wire fixing clamp clip and plug it into the repeater to power it on.
Page 14
User's Manual Figure 4-3 Power on the repeater...
User's Manual 5 Adding the Repeater to the Hub Before you connect repeater to the hub, install the DMSS app to your phone. This manual uses iOS as an example. Prerequisites Make sure that the version of the DMSS app is 1.94or later, and the hub is V1.001.R.20211215 or ●...
User's Manual 6 Installation Prerequisites Before installation, add the repeater to the hub and check the signal strength of the installation location. We recommend installing the repeater in a place with a signal strength of at least 2 bars. Background Information Use the provided screws to mount the repeater in locations accessible for future maintenance.
Page 17
User's Manual Figure 6-3 Secure the repeater...
User's Manual 7 Configuration You can view and edit general information of the repeater. 7.1 Viewing Status On the hub screen, select a repeater from the peripheral list, and then you can view the status of the repeater. Table 7-1 Status Parameter Value The status for whether the functions of the repeater are enabled or...
User's Manual Parameter Value The battery level of the repeater. : Fully charged. ● : Sufficient. ● : Moderate. ● Battery Level : Insufficient. ● : Low. ● If the battery level is low, the repeater can work for up to 3.5 hours. The tamper status of the repeater, which reacts to the detachment of Anti-tampering Status the body.
Page 20
User's Manual Parameter Description Tap Temporary Deactivate to enable or disable the functions of the repeater. Tap Enable , and then all peripheral messages will be ● forwarded to the alarm hub. Enable is set by default. Tap Only Disable Tamper Alarm, and then the system will ●...
Page 21
User's Manual Parameter Description Signal Strength Detection Check the current signal strength. Select from high, low, and automatic. ● The higher transmission power levels are, the further ● transmissions can travel, but power consumption increases. Transmit Power If you select Low, and then the siren will enter reduced sensitivity mode until you select another option.
IP video surveillance is not immune to cyber risks, but taking basic steps toward protecting and strengthening networks and networked appliances will make them less susceptible to attacks. Below are some tips and recommendations from Dahua on how to create a more secured security system.
Page 23
● to private networks. Enable IP/MAC address filtering function to limit the range of hosts allowed to access the ● device. More information Please visit Dahua official website security emergency response center for security announcements and the latest security recommendations.
Need help?
Do you have a question about the DHI-ARA43-W2 (868) and is the answer not in the manual?
Questions and answers