DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE.
READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION
RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.
TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL
AND LOCAL ELECTRICAL/BUILDING CODES. FOR CODE INTERPRETATION, CONSULT LOCAL CODE AUTHORITY
TERMINAL 
BLOCK  C
 
 
 
 
 
 
 
 
 
 
TERMINAL 
BLOCK 
!
ENSURE THAT ALL POWER IS
DISCONNECTED PRIOR TO WIRING
WIRING:
PULL UP TERMINAL BLOCK COVER (OPTIONAL) AS SHOWN IN
THE PICTURE. FEED THE SUPPLY WIRES THROUGH THE MAST
ARM, DRESS THEM SO THEY DO NOT INTERFERE WITH ANY
COMPONENTS AND SO THEY WILL NOT BE PINCHED IN THE
DOOR, AND CONNECT THEM TO THE PROPER TERMINALS ON
THE TERMINAL BLOCK. VERIFY THE SUPPLY VOLTAGE IS
CORRECT AS NOTED ON THE NAMEPLATE LABEL. IF SUPPLIED,
PUSH DOWN THE TERMINAL BLOCK COVER TO KEEP
TERMINALS COVERED.
!
FIXTURE MUST BE GROUNDED
TO FUNCTION AS INTENDED
TERMINAL BLOCK:
RECOMMENDED TORQUE FOR SCREWS 35 IN-LBS.
DRAWING NO. A72975 REV: C (FRONT)
American Electric Lighting a division of Acuity Brands Lighting
INSTALLATION INSTRUCTIONS
ATB2 SERIES LUMINAIRE
 
 
 
 
 
 
 
FITTER BOLTS 
MAST ARM 
 
OVER 
 
 
 
KNOCKOUT 
WARNING
WARNING
©2014 ACUITY BRANDS LIGHTING, INC. ALL RIGHTS RESERVED.
WARNING
!
WARNING
!
CAUTION
!
OVER-TORQUING OF FITTER CLAMP BOLTS CAN
CREATE CRACKS IN THE HOUSING CAUSING
THE FIXTURE TO FALL TO THE GROUND.
MOUNTING / LEVELING
DETERMINE THE SIZE OF THE MAST ARM. THIS LUMINAIRE IS
DESIGNED TO ACCOMMODATE A MAST ARM FROM 1/1/4" TO 2"
DIA. THE LUMINAIRE IS FACTORY SET TO MOUNT TO THE 1-1/4"
ARM. TO MOUNT TO A 2" ARM, A MODIFICATION MUST BE MADE.
THE REAR OPENING MUST BE ENLARGED. KNOCKOUTS ARE
CAST-IN AROUND THE REAR OPENING FOR THIS PURPOSE. TO
REMOVE THIS EXCESS MATERIAL, STRIKE WITH A HAMMER OR
GRASP WITH PLIERS AND BREAK OFF.
STANDARD MOUNTING
LOOSEN (DO NOT REMOVE) THE FITTER BOLTS. LIFT THE
LUMINAIRE INTO POSITION IN FRONT OF THE MAST ARM SUCH
THAT THE MAST ARM ENTERS THROUGH THE OPENING AT THE
REAR OF THE LUMINAIRE AND BETWEEN THE FITTER BRACKET
AND THE LUMINAIRE HOUSING. TIGHTEN FITTER BOLTS
TO 10-12 FT-LBS.
ANGLE LEVELING:
THIS LUMINAIRE IS DESIGNED TO ADJUST ± 5 DEGREES UP OR
DOWN SIDE. TO ADJUST THE LUMINAIRE TO THE UP SIDE, TIGHTEN
THE REAR FITTER BOLTS UNTIL GET THE DESIRED ANGLE, AND
THEN TIGHTEN THE FRONT FITTER BOLTS TO SECURE THE
LUMINAIRE. TO ADJUST TO THE DOWN SIDE TIGHTEN THE FRONT
FITTER BOLTS UNTIL GET THE DESIRED ANGLE, THEN TIGHTEN THE
REAR FITTER BOLTS TO SECURE THE LUMINAIRE.
OPTIONAL PHOTOCONTROL:
PLUG THE PHOTOCONTROL INTO THE RECEPTACLE ENSURING
GASKET IS FIRMLY SEATED. TWIST CLOCKWISE UNTIL IT LOCKS
INTO POSITION.
IF PHOTOCONTROL RECEPTACLE ROTATION IS REQUIRED, LOOSEN
THE TWO PHILIPS HEAD RECEPTACLE SCREWS. ROTATE
RECEPTACLE, MAXIMUM OF 360° , THEN RE-TIGHTEN SCREWS
UNTIL SNUG, USING 20-25 IN-LBS OF TORQUE.
IF PHOTOCONTROL RECEPTACLE ROTATION IS REQUIRED
FOR THE P3 / P7 OPTION, LOOSEN THE TWO PHILIPS HEAD
RECEPTACLE SCREWS COMPLETELY. ROTATE RECEPTACLE 90°,
180°, OR 270°, THEN RE-TIGHTEN SCREWS UNTIL SNUG, USING
20-25 IN-LBS OF TORQUE
CAUTION
!
:
:
PART NUMBER 057-70-72975

Advertisement

loading
Need help?

Need help?

Do you have a question about the ATB2 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AEL ATB2 Series

  • Page 1 American Electric Lighting a division of Acuity Brands Lighting INSTALLATION INSTRUCTIONS ATB2 SERIES LUMINAIRE WARNING DISCONNECT POWER BEFORE RELAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION WARNING RISK OF FIRE. PRODUCT FOR OUTDOOR INSTALLATION AND USE ONLY.
  • Page 2 American Electric Lighting a division of Acuity Brands Lighting INSTALLATION INSTRUCTIONS ATB2 SERIES LUMINAIRE WARNING THIS IS AN ELCTRONIC DEVICE AND SHOULD NOT BE LEFT EXPOSED TO THE ELEMENTS DURING STORAGE, TRANSPORTATION, OR INSTALLATION. IT IS RATED FOR OUTDOOR USE ONCE PROPERLY INSTALLED AND IN NORMAL CONDITION.
  • Page 3 Este instructivo aplica a todos los productos de AEL. número catálogo especifico, características eléctricas, se encuentran en la etiqueta del producto. Desconecte la alimentación eléctrica de la caja de fusibles antes de instalar el luminario.