Cattron Pump Boss III Quick Start Manual

Cattron Pump Boss III Quick Start Manual

Advertisement

Quick Links

Quick Start Guide
Pump Boss III™
1. Install the Pump Boss III MCU
The PBIII output functions relative to the OCU buttons are
identified in the user manual.
In some cases the implementation of an appropriate machine
main power control circuit is required using the Main Safety
output that has been allocated to that function. Additionally a
Reset function may have been defined to reset the machine.
Mount the 2.4GHz Antenna provided and connect using the line kit supplied to one of the antenna
ports.
Check the wiring and turn on the MCU power, the CBMCU LED A should be amber, LED B should be
green, LED F will be green when Main Safety outputs are OFF and red when they are ON.
When the PumpBoss OCU is started and in Active mode, LED E will flash with every received RF
message. NB: If the OCU has never been associated with the MCU, it will be necessary to carry out the
Association process, see next page.
The CAN LEDs will correspond to any defined and connected CAN bus.
Disposable Batteries
2. OCU Turn ON, Turn OFF and Status
If the Rapid Start option is programmed (normal from Jan 2024) press the ON
button until the haptic buzz is felt and the OCU will be transmitting, to get to a
Passive state for CattronLink or Association modes press the ON button very
briefly.
If Rapid Start is not programmed, press the ON button once to wake the OCU
from a sleep state, LEDs 1 and 2 will illuminate to indicate the state of the battery
charge, the OCU is now in a PASSIVE State, then press the ON button again to
start the OCU transmitting.
When the Stop switch is flashing the OCU and MCU are communicating, if the
Stop switch stops flashing, either the OCU is not associated with the MCU, or the
MCU is turned OFF or the distance between OCU and MCU is too great.
To Stop the machine, Press the Stop button.
If Rapid Stop is programmed (normal from Jan 2024) the OCU will go straight to
OFF
If Rapid Stop is not programmed the OCU will go to Passive and either pressing
STOP for 3 seconds or waiting 3 minutes will turn the OCU OFF.
When transmitting, if the battery is low the top center Status LED will flash
Amber, or if the battery is almost depleted it will flash Red and the OCUs haptic
function will also vibrate every 10 seconds.
9M60-9061-A008-EN | Dec 2023
OCUs with disposable
batteries (AA type) have
cross head screws
securing the battery
cover.
Rechargeable Batteries
RF
Module
K16
FUSE
OCUs with rechargeable
batteries have tamper proof
screws securing the battery
cover.
STOP
ON

Advertisement

loading
Need help?

Need help?

Do you have a question about the Pump Boss III and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cattron Pump Boss III

  • Page 1 Quick Start Guide Pump Boss III™ 1. Install the Pump Boss III MCU • The PBIII output functions relative to the OCU buttons are identified in the user manual. • In some cases the implementation of an appropriate machine main power control circuit is required using the Main Safety output that has been allocated to that function.
  • Page 2 Associating a new OCU with the Pump Boss III MCU For a new OCU that has never been associated with an MCU, the following Association process will need to be done once. Hold the OCU close to the antenna of the MCU - to ensure it connects to that MCU rather than any other MCU.