Page 1
N0181 F362CX F242HS N0241 Dear Owner Thank you for installing LG air conditioner. Your best choice guarantees you a great performance and service to make your life comfortable & pleasant. IMPORTANT • Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner.
Room Air Conditioner Owner’s Manual TABLE OF CONTENTS FOR YOUR RECORDS A. Safety Precautions ......3 Write the model and serial numbers here: B. Electrical Safety........8 Model # Temporary Use of an Adapter ....8 Serial # Temporary Use of an Extension Cord ...8 You can find them on a label on the side of each unit.
Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. I Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury.
Page 4
Safety Precautions Do not modify or extend the Do not install, remove, or Be cautious when power cable. re-install the unit by unpacking and installing yourself (customer). the product. • There is risk of fire or electric • There is risk of fire, electric •...
Page 5
Safety Precautions Do not store or use flammable If strange sounds, or small or When the product is soaked gas or combustibles near the smoke comes from product. Turn (flooded or submerged), product. the breaker off or disconnect the contact an Authorized power supply cable.
Page 6
Safety Precautions I Installation Always check for gas Install the drain hose to ensure Keep level even when (refrigerant) leakage after that water is drained away installing the product. installation or repair of product. properly. • Low refrigerant levels may •...
Page 7
Safety Precautions Do not block the inlet or Use a soft cloth to clean. Do Do not touch the metal parts of outlet of air flow. not use harsh detergents, the product when removing the solvents, etc. air filter. They are very sharp! •...
Electrical Safety Electrical Safety • This appliance must be properly grounded. To minimize the risk of electric shock, you must alway plug into a grounded oulet. • Do not cut or remove the grounding prong from the power plug. • Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
Product Introduction Product Introduction Here is a brief introduction of the indoor and outdoor units. Please see the information specific to your indoor unit type. Indoor Units Standard Split Type Art Cool Mirroy Type Display panel LED indicators Display panel LCD indicators Air inlet Grille tab Air inlet...
Product Introduction Outdoor Unit Air intake vents Connecting wires Refrigerant pipes Drain hose Air outlet vents Base plate 10 Room Air Conditioner...
Operating Instructions Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTE 1.
Operating Instructions Wireless Remote Controller 1. START/STOP BUTTON The controls will look like the following. Used to turn off/on the unit. 2. OPERATION MODE SELECTION BUTTON Signal transmitter Used to select the operation mode. 3. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. 4.
Operating Instructions Operation Mode Press the START/STOP BUTTON to turn the unit on. The unit will respond with a beep. Open the door of the remote controller and press the operation mode button. Each time the button is pressed, the operation mode is shifted in the direction of the arrow.
Operating Instructions Healthy Dehumidification Operation During Healthy Dehumidification Operation ❏ If you select the dehumidification mode on the OPERATION MODE SELECTION BUTTON, the product starts to run the dehumidification function. It automatically sets the room temperature and airflow volume to the best condition for dehumidification, based on the sensed current room Healthy temperature.
Operating Instructions Jet Cool/Heat Operation Jet cool function can be used to cool the room quickly in hot summer. When this function is turned on, the air conditioner runs in cooling operation mode with super high fan speed and 18°C setting temperature for 30 minutes for fast and effective cooling.
Operating Instructions Forced operation Operation procedures when the remote control can't be used. The operation will be started if the ON/OFF button is pressed. If you want to stop operation, re-press the button. On/Off ON/OFF On/Off On/Off button button button button Heat pump Model Cooling Model...
Operating Instructions Sleep Mode 1. Press the SLEEP MODE AUTO BUTTON to set the time when you want the unit to stop automatically. 2. The timer is programmed in one-hour increments by pressing the SLEEP MODE AUTO BUTTON 1 to 7 times. The sleep mode is available for 1 to 7 times.
Operating Instructions Vertical / Horizontal Airflow Direction Control (Optional) The up/down airflow (Vertical airflow) can be The left/right(Horizontal airflow) can be adjusted adjusted by using the remote controller. by using the remote control. 1. Press the START/STOP BUTTON to start the - F182CR, F242CR unit.
Operating Instructions Air Circulation Mode This operation circulates the air without cooling or heating. It can be activated by pressing the AIR CIRCULATION BUTTON. Once the air circulation is activated you can select the air speed by pressing the INDOOR FAN SPEED SELECTOR BUTTON. NOTE CHAOS Air economizes power consumption and prevents overcooling.
Maintenance and Service Maintenance and Service Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord. Indoor Unit Clean the unit with a soft dry cloth. Do not use bleach or abrasives. Never use any of these •...
Page 21
Maintenance and Service Deodorizing Filter 1. After removing the air filters, pull slightly forward to remove the TRIPLE DEODORIZING filter. Deodorizer 2. Dry in the sunlight for two hours. filter 3. Re-install the TRIPLE DEODORIZING filter to the original position. Replacement of purifying filter (Optional) Recommended use period : About 2 years Open the front panel as shown.
Maintenance and Service Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. Operation Tips! Do not overcool the room.
Maintenance and Service Troubleshooting Tips! Save time and money! The air conditioner may be operating abnormally when: Problem Possible Causes What To Do I The fuse is blown/circuit • Check the house fuse/circuit breaker box breaker is tripped. and replace the fuse or reset the breaker. I Power failure.