MOTION-12D
12-channel hoist controller
with analogue remote control
User's manual
First edition
Copyright 2017

Advertisement

loading
Need help?

Need help?

Do you have a question about the MOTION-12D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PLS MOTION-12D

  • Page 1 MOTION-12D 12-channel hoist controller with analogue remote control User’s manual First edition Copyright 2017...
  • Page 2 MOTION-12D Hoist Controller Dear Customer! Thank you for chose PLS Electronics product. If you have any technical question or you looking for other equipments, don’t hesitate to take up the contact with our sales representative or with the manufacturer at the www.pls.hu...
  • Page 3 PLS Kft – www.pls.hu 1. Control parts Front parts Link out connector for start and E-Stop signals (XLR, 7-pin female) Link in connector for start and E-Stop signals (XLR, 7-pin male) EMERGENCY STOP button (Rotate to release type) Fault state LED (Emergency stop condition occurred)
  • Page 4 MOTION-12D Hoist Controller 11. Mains input state LEDs (they are connected after the RCD). Output protector MCBs for output 1-6 (Each output is protected with C6A 3P MCBs) 12. Output protector MCBs for output 7-12 (Each output is protected with C6A 3P MCBs) Back parts 1A.
  • Page 5 PLS Kft – www.pls.hu Remote controller parts 1. Motor direction status LEDs: RED: Going Down GREEN: Going Up Blind: Motor OFF – No movement 2. Motor direction select three-position switches (UP/OFF/DOWN 3. EMERGENCY STOP button (Rotate to release type) 4. START button (When illuminated in Green the system is ready to start movement) Only if the wiring of the motors and the cables/breakout boxes are correct.
  • Page 6 MOTION-12D Hoist Controller Remote controller parts (U/D Version controller) 1. Motor enabled status LEDs GREEN: Selected to move Blind: Motor OFF-No movement) 2. Motor enable switches (Enabled/OFF) 3. EMERGENCY STOP button (Rotate to release type) 4. START UP button (All enabled motors start to move up 5.
  • Page 7: Safety First

    PLS Kft – www.pls.hu 2. Installation of the unit After unpacking the apparatus is ready for use. Not to make the cable longer! If it is short, use standard extension. Operating with injured cable is perilous! CAUTION! The apparatus is NOT waterproof! Protect it from liquids! Not to use outdoors without appropriate preventive measures.
  • Page 8 MOTION-12D Hoist Controller 3A. Power-up sequence (stand-alone mode) Before you power up the controller connect the following parts to the controller: 1. Connect the remote cable to the backside 37-pin connector (7). Take care to be fully plugged in and fixed the input plug with the rotating ring.
  • Page 9 The Link feature is a unique solution where the E-Stop signal and the Start signal are linked to all PLS made D and S type hoist controller with keeping the double protection loop required by the machine directives. Before you power up the controller connect the following parts to the controller: 1.
  • Page 10: Troubleshooting

    MOTION-12D Hoist Controller If there is no Emergency state (no RED signal by Fault state LED) and the blue (Reset) push button lights, press the Reset buttons on each linked controller. After release of reset buttons the controllers go to Ready state. You can press the reset buttons individually, does not need to press them in the same time.
  • Page 11 PLS Kft – www.pls.hu Fault indicator does not light but the Blue LED signal does not either: • Try to press the reset button, if the controller goes to ready state the blue LED broken, contact the sales representatives for replacement part. You can use the controller without problem.
  • Page 12 MOTION-12D Hoist Controller 6. External E-Stop input and wiring 7. Remote controller input pin layout Function Function Motor 1-UP Motor 10-DOWN Motor 1-DOWN Motor 11-UP Motor 2-UP Motor 11-DOWN Motor 2-DOWN Motor 12-UP Motor 3-UP Motor 12-DOWN Motor 3-DOWN 24VAC-A...
  • Page 13 13, 14, 15, 16 and the PROTECTIVE EARTH (PE) side connectors Recommended 16-pole male plug (optionally orderable form PLS): Male insert: HDC HE 16 MT (Tension clamp, Weidmüller order no.: 1745840000) or HDC HE 16 MS (Screw connection, Weidmüller order no.: 1207500000) House: HDC 16B TOBU 1M25G (M25 cable gland Weidmüller order no.: 1788210000)
  • Page 14: Technical Information

    MOTION-12D Hoist Controller 9. CEE connectors pin layout (front view) Technical information Power supply: ............TN-S 3x230V/400VAC ±10% (3 x 32A) Power draw with open outputs:......10W Output connectors:..........12 x CEE16/4P (or optional 5P) Optional 3x 16-pole ‘Harting’ (-H16) or 3x 19-pole ‘Socapex (-SX) Input connectors:..........7-pole XLR male/female for Link in/out...
  • Page 15: Declaration Of Conformity

    Declaration of Conformity We, PLS Electronics Limited declare under sole responsibility that the product: Product name: .......... MOTION-12D (12-channel hoist controller series) Product model (output variations):.... C (12x 4-pole 16A CEE) H16 (12x 4-pole 16A CEE and 3 x 16-pole ’Harting’) SX (12x 4-pole 16A CEE and 3 x 19-pole Socapex) Serial Number:.........