12-channel hoist controller with analogue remote control (16 pages)
Summary of Contents for PLS MOTION-12S
Page 1
MOTION-12S 12-channel hoist controller with local direction control User’s manual First edition Copyright 2017...
Page 2
MOTION-12S Hoist Controller Dear Customer! Thank you for chose PLS Electronics product. If you have any technical question or you looking for other equipments, don’t hesitate to take up the contact with our sales representative or with the manufacturer at the www.pls.hu...
Page 3
PLS Kft – www.pls.hu 1. Control parts Front parts Link out connector for start and E-Stop signals (XLR, 7-pin female) Link in connector for start and E-Stop signals (XLR, 7-pin male) EMERGENCY STOP button (Rotate to release type) Reset button (Light in blue when the unit needs reset)
Page 4
MOTION-12S Hoist Controller Back parts 1A. Optional 19-pole ‘Socapex’ outputs 1B. Optional 16-pole ‘Harting’ outputs 2. AUX 16A single phase output 1 3. AUX 16A single phase output 2 4. Control fuses (T1A, 5x20mm, High Breaking Capability type) 5. External Emergency Stop input 1 (4-pole female XLR; Dummy Plug included) 6.
Page 5
PLS Kft – www.pls.hu Optional Remote controller parts 1. EMERGENCY STOP button (Rotate to release type) 2. START button (When illuminated in Green the system is ready to start movement) Connect the attached 9-pin dummy plug to the remote controller input if you do not want to use the optional...
MOTION-12S Hoist Controller 2. Installation of the unit After unpacking the apparatus is ready for use. Not to make the cable longer! If it is short, use standard extension. Operating with injured cable is perilous! CAUTION! The apparatus is NOT waterproof! Protect it from liquids! Not to use outdoors without appropriate preventive measures.
Page 7
PLS Kft – www.pls.hu 3A. Power-up sequence (stand-alone mode) Before you power up the controller connect the following parts to the controller: 1. Connect the optional remote controller or the attached dummy plug to the 9-pin connector on the backside. Take care to be fully plugged in and fixed the input plug with the rotating ring.
Page 8
The Link feature is a unique solution where the E-Stop signal and the Start signal are linked to all PLS made D and S type hoist controller with keeping the double protection loop required by the machine directives. Before you power up the controller connect the following parts to the controller: 1.
PLS Kft – www.pls.hu If there is no Emergency state (no RED signal by Fault state LED) and the blue (Reset) push button lights, press the Reset buttons on each linked controller. After release of reset buttons the controllers go to Ready state. You can press the reset buttons individually, does not need to press them in the same time.
Page 10
MOTION-12S Hoist Controller Fault indicator does not light but the Blue LED signal does not either: • Try to press the reset button, if the controller goes to ready state the blue LED broken, contact the sales representatives for replacement part. You can use the controller without problem.
Page 11
PLS Kft – www.pls.hu 6. External E-Stop input and wiring 7. Optional remote controller input pin layout Function +24VDC GND (24VDC) E-Stop Out1 E-Stop Out2 START Ready signal NC (not connected) NC (not connected Matched male type: SP2110/P9 (WEIPU) Connect the attached 9-pin dummy plug to the remote...
Page 12
13, 14, 15, 16 and the PROTECTIVE EARTH (PE) side connectors Recommended 16-pole male plug (optionally orderable form PLS): Male insert: HDC HE 16 MT (Tension clamp, Weidmüller order no.: 1745840000) or HDC HE 16 MS (Screw connection, Weidmüller order no.: 1207500000) House: HDC 16B TOBU 1M25G (M25 cable gland Weidmüller order no.: 1788210000)
PLS Kft – www.pls.hu 9. CEE connectors pin layout (front view) Technical information Power supply: ............TN-S 3x230V/400VAC ±10% (3 x 32A) Power draw with open outputs:......10W Output connectors:..........12 x CEE16/4P (or optional 5P) Optional 3x 16-pole ‘Harting’ (-H16) or 3x 19-pole ‘Socapex (-SX) Input connectors:..........7-pole XLR male/female for Link in/out...
Declaration of Conformity We, PLS Electronics Limited declare under sole responsibility that the product: Product name: .......... MOTION-12S (12-channel hoist controller series) Product model (output variations):.... C (12x 4-pole 16A CEE) H16 (12x 4-pole 16A CEE and 3 x 16-pole ’Harting’) SX (12x 4-pole 16A CEE and 3 x 19-pole Socapex) Serial Number:.........
Need help?
Do you have a question about the MOTION-12S and is the answer not in the manual?
Questions and answers