  • Page 1 POScenter Poscenter SG-110-BT Full User`s manual...
  • Page 2: Precautions

    Precautions Please read everything in the manual carefully before using the product described in this manual, and read the following notes carefully in order to ensure that the bar code scanning equipment according to the design indicators of safe use, please carefully keep the instructions, so that the future at any time to check.
  • Page 3: Revision History

    Revision History Date Version Describe 2018-10-20 Initial version Remove invalid content 2018-11-20 Remove the hand-scanned phone 2018-12-15 barcode, add Han XinCode,modify the manual Chinese word description. 2019-03-15 New series of common feature version manual 2019-08-28 Add some suffix samples;add Chinese keyboard 2019-8-31 Format adjustment 2019-11-15...
  • Page 4: Table Of Contents

    Table of Contents Precautions........................2 Revision History ......................3 Foreword ........................11 Brief Introduction ..................11 Chapter Outline ..................11 Chapter 1 Connection and Basic Settings ..............12 Introduction ..................12 Unpacking ....................12 Device Connection ................12 RS232 Connection ................13 Barcode Reading ..................14 Defaults Setting ..................15 Factory Default Setting .................15 Chapter 2 Interface Type ...................
  • Page 5 2D Barcode ..................26 Codabar ....................27 On/Off ........................27 Start/Stop Characters ..................27 Check Character ....................27 Concatenation...................... 29 Message Length ....................30 Code 39 ....................31 Code 39 On/Off ....................31 Start/ Stop Characters ..................31 Check Character ....................32 Message Length ....................32 Code 39 Append ...................33 Code 32 Pharmaceutical (PARAF) ............34 FULL ASCII ..................35...
  • Page 6 Straight 2 of 5 IATA (two-bar start/stop) ..........44 On/Off ........................44 Message Length ....................44 Matrix 2 of 5..................45 On/Off ........................45 Message Length ....................45 Check........................46 Code 11 ....................47 On/Off ........................47 Check Digits Required ..................47 Message Length ....................48 Code 128 ....................49 On/Off ........................
  • Page 7 UPC-E0 ....................56 On/Off ........................56 Expand ......................... 57 Addenda Required ....................57 Addenda Separator ....................57 Check Digit ......................58 Number System ....................59 Addenda ....................... 59 UPC-E1 ....................60 EAN/JAN-13 ..................60 On/Off ........................60 Check Digit ......................61 Addenda ....................... 61 Addenda Required ....................
  • Page 8 GS1 DataBar Limited ................68 On/Off ........................68 GS1 DataBar Expanded ...............69 On/Off ........................69 Message Length ....................69 PDF417 ....................70 On/Off ........................70 Message Length ....................70 QR Code ....................71 On/Off ........................71 Message Length ....................71 Data Matrix ...................72 On/Off ........................
  • Page 9 Message Length ....................78 Micropdf ....................79 On/Off ........................79 Message Length ....................79 Composites ..................80 On/Off ........................80 Message Length ....................80 Codablock A ..................81 On/Off ........................81 Message Length ....................81 Codablock F ..................82 On/Off ........................82 Message Length ....................82 Chapter 5 Utilities......................
  • Page 10: Foreword

    Foreword Brief Introduction This manual provides bar code scanning equipment Start-up and configuration instructions, as well as maintenance and customer support information. Chapter Outline Chapter 1 Connections and Basic Settings :introduces the method and default settings for bar code scanning devices Chapter 2 Interface Types : Describes the main configuration of interface types Chapter 3 Input / Output Settings: Describes Configuration Decoding Success / Failed LED and Buzzer Response...
  • Page 11: Chapter 1 Connection And Basic Settings

    Chapter 1 Connection and Basic Settings Introduction The Newtologic barcode scanner supports three connection methods. Please follow the appropriate connection procedure to connect the barcode scanner. Unpacking To open the product packaging, perform the following steps: • Remove the scanner and its accessories and inspect for damage during shipment.
  • Page 12: Rs232 Connection

    RS232 Connection Connect the device interface (RJ45 connector) of the RS-232 cable to the scanner. Connect the host interface (RS-232 interface) of the RS-232 cable to the host. The barcode scanner is humming. Verify the operation by scanning the Sample Symbols at the end of this manual.
  • Page 13: Barcode Reading

    Barcode Reading The barcode scanner has a line of sight/point that projects a red aiming beam that corresponds to the horizontal field of view of the barcode scanner. The line of sight/point should be at the center of the barcode, but it can be positioned in any direction to facilitate reading.
  • Page 14: Defaults Setting

    Defaults Setting Factory Default Setting Scan the "Load Factory Defaults" barcode below to reset the barcode scanner to the factory default settings. (800006.) Load Factory Defaults...
  • Page 15: Chapter 2 Interface Type

    Chapter 2 Interface Type Introduction This chapter introduces the USB and RS232 interface types and lists their related configurations. RS232 Connect RS232 interface, you need to scan the "RS232" barcode, the serial port related configuration is: 9600 baud rate, 8 data bits, no parity, 1 stop bit, add carriage return and line feed by default.
  • Page 16: Chapter 3 Data Editing

    Chapter 3 Data Editing Introduction This chapter describes how to add prefixes and suffixes. • Default prefix = None. Default suffix = None. • A prefix or suffix may be added or cleared from one symbology or all symbologies. • You can add any prefix or suffix from the ASCII Conversion Chart deplus Code I.D.
  • Page 17: Add Prefix Or Suffix

    Add Prefix or Suffix Step 1. Scan the Add Prefix or Add Suffix symbol Step 2. Determine the 2 digit Hex value from the Symbology Chart for the symbology to which you want to apply the prefix or suffix. For example, for Code 11, Code ID is “h”...
  • Page 18: Add A Suffix To A Specific Symbology

    Example Add a Suffix to a specific symbology To send a CR (carriage return)Suffix for code 128. only: Step 1. Scan Add Suffix. Step 2. Determine the 2 digit hex value from the Symbology Charts code 128. Step 3. Scan 6, 3 from the Programming Chart inside the back cover of this manual.
  • Page 19: To Add A Carriage Return Suffix To All Symbologies

    To Add a Carriage Return Suffix to All Symbologies Scan the following barcode if you wish to add a carriage return suffix to all symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies. (890000.) Add CR Suffix All Symbologies To Add a Line Break Suffix to All Symbologies...
  • Page 20: Clear Prefixes Or Suffixes

    Clear Prefixes or Suffixes You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. If you have been entering prefixes and suffixes for single sym- bologies, you can use Clear One Prefix (Suffix) to delete a specific char- acter from a symbology.
  • Page 21: Suffix Selections

    (889003.) Clear All Prefixes Suffix Selections (888002.) Add Suffix (888004.) Clear One Suffix (888003.) Clear All Suffixes...
  • Page 22: Function Code Transmit

    Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Default = Disable. (8080071.) *Enable (8080070.) Disable Intermessage Delay An intermessage delay of up to 5000 milliseconds (in 5ms increments) may be placed between each scan transmission.
  • Page 23: Chapter 4 Symbologies

    Chapter 4 Symbologies Introduction Each type of barcode has its own unique properties. The barcode scanner can be adjusted to accommodate these property changes through the configuration code in this chapter. The fewer the barcode types, the faster the barcode scanner can read. You can disable the barcode scanner to read the barcode types that will not be used to improve the performance of the barcode scanner.
  • Page 24: All Symbologies

    All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On barcode. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On barcode for that particular symbology. (9990011.) All Symbologies On (9990010.)
  • Page 25: 1D Barcode

    1D Barcode If the bar code scanning device needs to decode all the one-dimensional code systems, please scan the bar code of “All 1D Barcode on”. Only solve specific code system, please scan " All 1D Barcode off" . (9950040.) All 1D Barcode on (9950041.) All 1D Barcode off...
  • Page 26: Codabar

    Codabar (900000.) Default All Codabar Settings On/Off (9000031.) * On (9000030.) Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters.Default = Don’t Transmit. (9000061.) Transmit (9000060.) * Don’t Transmit Check Character No Check Character indicates that the scanner reads and transmits barcode data with or without a check character.
  • Page 27 (9000010.) * No Check Character (9000011.) Validate but Don’t Transmit (9000012.) Validate and Transmit...
  • Page 28: Concatenation

    Concatenation Codabar supports symbol concatenation. When you enable concatena- tion, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two mes- sages are concatenated into one with the “D” characters omitted. A 1 2 3 4 D D 5 6 7 8A Select Require to prevent the scanner from decoding a single “D”...
  • Page 29: Message Length

    Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. (900005.) Minimum Message Length (900004.) Maximum Message Length...
  • Page 30: Code 39

    Code 39 < Default All Code 39 Settings > (901000.) Default All Code 39 Settings Code 39 On/Off (9010011.) * On (9010010.) Start/ Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.
  • Page 31: Check Character

    Check Character No Check Character indicates that the scanner reads and transmits bar- code data with or without a check character. When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 barcodes printed with a check character, but will not transmit the check character with the scanned data.
  • Page 32: Code 39 Append

    Code 39 Append This function allows the scanner to append the data from several Code 39 barcodes together before transmitting them to the host computer. When the scanner encounters a Code 39 barcode with the append trigger char- acter(s), it buffers Code 39 barcodes until it reads a Code 39 barcode that does not have the append trigger.
  • Page 33: Code 32 Pharmaceutical (Paraf)

    Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Ital- ian pharmacies. This symbology is also known as PARAF. When you configure code32, you need to turn on code39 before you configure it. (9010051.) (9010050.) * Off...
  • Page 34: Full Ascii

    FULL ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar- code symbol will be interpreted as a single character. For example:$V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #.
  • Page 35: Interleaved 2 Of 5

    Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > (902000.) Default All Interleaved 2 of 5 Settings On/Off (9020021.) * On (9020020.) Check Digit No Check Digit indicates that the scanner reads and transmits barcode data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 barcodes printed with a check digit, but will not transmit the check digit with the scanned data.
  • Page 36 (9020011.) Validate, but Don’t Transmit (9020012.) Validate and Transmit...
  • Page 37: Message Length

    Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. (902004.) Minimum Message Length (902003.) Maximum Message Length...
  • Page 38: Nec 2 Of 5

    NEC 2 of 5 < Default All NEC 2 of 5 Settings > (903000.) Default All NEC 2 of 5 Settings On/Off (9030011.) * On (9030010.) Check Digit No Check Digit indicates that the scanner reads and transmits barcode data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 barcodes printed with a check digit, but will not transmit the check digit with the scanned data.
  • Page 39 (9030021.) Validate, but Don’t Transmit (9030022.) Validate and Transmit...
  • Page 40: Message Length

    Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. (903004.) Minimum Message Length (903003.) Maximum Message Length...
  • Page 41: Code 93

    Code 93 < Default All Code 93 Settings > (904000.) Default All Code 93 Settings On/Off (9040021.) * On (9040020.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 0-80.
  • Page 42: Straight 2 Of 5 Industrial (Three-Bar Start/Stop)

    Straight 2 of 5 Industrial (three-bar start/stop) <Default All Straight 2 of 5 Industrial Settings> (905000.) Default All Straight 2 of 5 Industrial (three-bar start/stop)Settings On/Off (9050011.) (9050010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
  • Page 43: Straight 2 Of 5 Iata (Two-Bar Start/Stop)

    Straight 2 of 5 IATA (two-bar start/stop) <Default All Straight 2 of 5 IATA Settings> (906000.) Default All Straight 2 of 5 IATA (two-bar start/stop)Settings On/Off (9060011.) (9060010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
  • Page 44: Matrix 2 Of 5

    Matrix 2 of 5 <Default All Matrix 2 of 5 Settings> (907000.) Default All Matrix 2 of 5 Settings On/Off (9070011.) (9070010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
  • Page 45: Check

    Check Scan the barcode below to enable or disable the check function of matrix25. (9070051.) Enable Check Function (9070050.) Disable Check Function...
  • Page 46: Code 11

    Code 11 <Default All Settings> (908000.) Default All Code 11 Settings On/Off (9080021.) (9080020.) * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 barcodes. Default = Two Check Digits. (3110280.) One Check Digit (3110281.) * Two Check Digits...
  • Page 47: Message Length

    Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. (908004.) Minimum Message Length (908003.) Maximum Message Length...
  • Page 48: Code 128

    Code 128 <Default All Code 128 Settings> (909000.) Default All Code 128 Settings On/Off (9090011.) * On (9090010.) ISBT 128 Concatenation (9020051.) ISBT 128 On (9020050.) *ISBT 128 Off...
  • Page 49: Message Length

    Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. (909003.) Minimum Message Length (909002.) Maximum Message Length...
  • Page 50: Gs1-128

    GS1-128 <Default All GS1-128 Settings> (910000.) Default All GS1-128 Settings On/Off (9100011.) * On (9100010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80. (910003.) Minimum Message Length (910002.)
  • Page 51: Telepen

    Telepen <Default All Telepen Settings> (911000.) Default All Telepen Settings On/Off (9110011.) (9110010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. (911003.) Minimum Message Length (911002.)
  • Page 52: Upc-A

    UPC-A <Default All UPC-A Settings> (912000.) Default All UPC-A Settings (9120031.) * On (9120030.) Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. (9120041.) * On (9120040.)
  • Page 53: Number System

    Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. (9120051.) * On (9120050.) Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
  • Page 54: Addenda Required

    Addenda Required When Required is scanned, the scanner will only read UPC-A barcodes that have addenda. You must then turn on a 2 or 5 digit addenda. Default = Not Required. (9120061.) Required (9120060.) * Not Required Addenda Separator When this feature is on, there is a space between the data from the barcode and the data from the addenda.
  • Page 55: Upc-E0

    UPC-E0 <Default All UPC-E Settings> (914000.) Default All UPC-E0 Settings On/Off Most U.P.C. barcodes lead with the 0 number system. To read these codes, use the *UPC-E0 On selection. If you need to read codes that lead with the 1 number system, use UPC-E1. Default = On. (9140101.) * UPC-E0 On (9140100.)
  • Page 56: Expand

    Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. (9140021.) (9140020.) * Off Addenda Required When Required is scanned, the scanner will only read UPC-E barcodes that have addenda. Default = Not Required. (9140031.) Required (9140030.)
  • Page 57: Check Digit

    (9140040.) Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. (9140051.) (9140050.)
  • Page 58: Number System

    Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. To prevent transmission, scan Off. Default = On. (9140061.) * On (9140060.)
  • Page 59: Upc-E1

    UPC-E1 Most U.P.C. barcodes lead with the 0 number system. For these codes, use UPC-E0. If you need to read codes that lead with the 1 number system, use the UPC-E1 On selection. Default = Off. (9140091.) UPC-E1 On (9140090.) EAN/JAN-13 * UPC-E1 Off <Default All EAN/JAN Settings>...
  • Page 60: Check Digit

    Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. (9150021.) * On (9150020.) Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda.
  • Page 61: Addenda Required

    Addenda Required When Required is scanned, the scanner will only read EAN/JAN-13 barcodes that have addenda. Default = Not Required. (9150051.) Required (9150050.) * Not Required Addenda Separator When this feature is On, there is a space between the data from the barcode and the data from the addenda.
  • Page 62: Ean/Jan-8

    EAN/JAN-8 <Default All EAN/JAN-8 Settings> (916000.) Default All EAN/JAN-8 Settings On/Off (9160011.) * On Check Digit (9160010.) This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. (9160021.) * On (9160020.)
  • Page 63: Addenda Required

    (9160031.) 2 Digit Addenda On (9160030.) * 2 Digit Addenda Off (9160041.) 5 Digit Addenda On (9160040.) * 5 Digit Addenda Off Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 barcodes that have addenda. Default = Not Required. (9160051.) Required (9160050.)
  • Page 64: Addenda Separator

    Addenda Separator When this feature is On, there is a space between the data from the barcode and the data from the addenda. When turned Off, there is no space. Default = On. (9160061.) * On (9160060.)
  • Page 65: Msi

    <Default All MSI Settings> (917000.) Default All MSI Settings On/Off (9170011.) (9170010.) * Off...
  • Page 66: Check Characte

    Check Characte MSI barcodes use different types of check characters. You can configure the barcode scanner to read the MSI barcode using the check character. Default = Validate MOD 10, but Don’t Transmit When Check Character is set to Validate MOD 10 and Transmit, the scanner will only read MSI barcodes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned data.
  • Page 67: Gs1 Databar Omnidirectional

    GS1 DataBar Omnidirectional < Default All GS1 DataBar Omnidirectional Settings > (918000.) Default All GS1 DataBar Omnidirectional Settings On/Off (9180011.) * On (9180010.) GS1 DataBar Limited < Default All GS1 DataBar Limited Settings > (919000.) Default All GS1 DataBar Limited Settings On/Off (9190011.) * On...
  • Page 68: Gs1 Databar Expanded

    GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > (920000.) Default All GS1 DataBar Expanded Settings On/Off (9200011.) * On (9200010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 4-74.
  • Page 69: Pdf417

    PDF417 < Default All PDF417 Settings > (924000.) Default All PD417 Settings On/Off (9240011.) * On (9240010) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750. (924003.) Minimum Message Length (924002.)
  • Page 70: Qr Code

    QR Code < Default All QR Code Settings > (928000.) Default All QR Code Settings On/Off This selection applies to both QR Code and Micro QR Code. (9280011.) * On (9280010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
  • Page 71: Data Matrix

    Data Matrix < Default All Data Matrix Settings > (930000.) Default All Data Matrix Settings On/Off (9300011.) * On (9300010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-3116.
  • Page 72: Aztec Code

    Aztec Code < Default All Aztec Code Settings > (931000.) Default All Aztec Code Settings On/Off (9310011.) * On (9310010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-3832.
  • Page 73: China Post (Hong Kong 2 Of 5)

    China Post (Hong Kong 2 of 5) <Default All China Post (Hong Kong 2 of 5) Settings> (936000.) Default All China Post (Hong Kong 2 of 5)Settings On/Off (9360011.) (9360010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
  • Page 74: Korea Post

    Korea Post <Default All Korea Post Settings> (937000.) Default All Korea Post Settings On/Off (9370011.) (9370010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-80.
  • Page 75: Check Digit

    Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data. Default = Don’t Transmit. (9370041.) (9370040.) * Off Han Xin Code <Default All Han Xin Code Settings> (932000.) Default All Han Xin Code Settings On/Off (9320011.)
  • Page 76 (932003.) Minimum Message Length (932002.) Maximum Message Length...
  • Page 77: Maxi Code

    Maxi code <defalt all maxi code settings> (929000.) On/Off (9290011.) (9290010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-150. Minimum Default = 1, Maximum Default = 150. (929003.) Minimum Message Length (929002.)
  • Page 78: Micropdf

    Micropdf <defalt all micropdf settings> (925000.) On/Off (9250011.) (9250010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-366. Minimum Default = 1, Maximum Default = 366. (925003.) Minimum Message Length (925002.)
  • Page 79: Composites

    Composites <defalt all composites settings> (926000.) On/Off (9260011.) (9260010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-2435. Minimum Default = 1, Maximum Default = 2435. (926004.) Minimum Message Length (926003.)
  • Page 80: Codablock A

    Codablock A <defalt all composites settings> (922000.) On/Off (9220011.) (9220010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600. (922003.) Minimum Message Length (922002.)
  • Page 81: Codablock F

    Codablock F <defalt all composites settings> (923000.) On/Off (9230011.) (9230010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048. (923003.) Minimum Message Length (923002.)
  • Page 82: Chapter 5 Utilities

    Chapter 5 Utilities Show Software Revision Scan the barcode below to output the current software revision, unit serial number, and other product information. (809005.) Show Revision...
  • Page 83: Chapter 6 Common Problems And Solutions

    Chapter 6 Common Problems And Solutions Problem: The barcode scanner does not work. possible reason: 1. The barcode scanner is not powered, check the power of the equipment. If you are using an incorrect cable, use the cable that was originally configured. The cable interface is loose and reconnected.
  • Page 84: Chapter 7 Maintenance And Customer Service

    Chapter 7 Maintenance And Customer Service Maintenance Stains and dust on the scanning window can sometimes affect the normal operation of the barcode scanner. When cleaning, use a good quality tissue to wipe gently, or use a soft cloth to clean. If you use a paper with poor paper quality for a long time, it will damage the surface finish of the window and affect the reading effect of the barcode scanner.
  • Page 85: Chapter 8 Bluetooth Bar Code Description

    Chapter 8 Bluetooth bar code description Sound related settings Mute Enter setting mode: Low volume: Exit setting mode: Medium volume: Display version information: High volume: Restore default settings: International keyboard: Buzzer frequency 2K: Enter normal mode: Compulsory pairing with Dongle: Enter inventory mode:...
  • Page 86 Never sleep: Display total storage entries: Hibernate now: Clear inventory data: Sleep time 30S: Fast transmission: Fast transmission: Sleep time 1 minute: Low-speed transmission: Sleep time 2 minutes: Ultra low speed transmission: Sleep time 5 minutes: 2.4G mode: Sleep time 10 minutes: Turn off double-click to pop up/hide the HID keyboard: Sleep time 30 minutes:...
  • Page 87: Example

    example: 1. 2.4G mode After plugging Dongle into the computer and the computer identifying Dongle successfully, pls. scan “Enter Settings”-“2.4G Mode”-“Connect Dongle”-“Exit Settings” in sequence to pair. After connect successfully, the blue colored lights will be on. (Note: For the meaning of indicator refer to part 7) ①Enter settings ②2.4G Mode...
  • Page 88 3. Function configuration 3.1.Configure carriage return (CR) line feed (LF) Scan “Enter Settings” to start functional setting. To scan one of the functional barcode below as you needed, then need to scan “Exit Settings” to complete the functional setting Enter settings Add CR suffix Add LF suffix Add CR+LF suffix...
  • Page 89 5. Pull up and hide keyboards in Android, iOS operating system device (Bluetooth Function) A: Start the scanner, scan “Enter Setting Mode” barcode. Enter Settings B: Scan the codes below to pull up or hide the iOS keyboard Pull up or hide iOS keyboard Trigger twice to pull up iOS keyboard Trigger twice to disable iOS keyboard C.
  • Page 90 6.Communication mode switching (Optional) A:Start the scanner, scan “ Enter Setting Mode” barcode. Enter Settings B : Select the communication mode barcode according to your need. 2.4G Wireless Mode Bluetooth HID Mode Bluetooth SPP Mode Bluetooth BLE Mode C : Scan “Exit Setting Mode” barcode Exit Settings...
  • Page 91 7. Language Settings A:Switch on the scanner and scan “Enter Setting Mode” barcode Enter Settings B: Select your intended keyboard language English Germany French Spanish Italian Japanese For PC termninal only, American keyboard language output C : Scan “Exit Setting Mode” barcode Exit Settings...
  • Page 92 8. Remove prefix and suffix setting A:Start the scanner and scan “Enter Setting Mode” barcode Enter Settings B: Scan "Remove Prefix", "Remove Suffix" barcode Remove Prefix Remove Suffix C: Scan the barcode according to your need to remove the bits Remove 1bit Remove 2bits Remove 3bits...
  • Page 93 9. Prefix and Suffix Setting A:Start the scanner and scan “Enter Setting Mode” barcode Enter Settings B: Scan the "Allow for Prefix Adding" or "Allow for Suffix Adding" setting barcode Allow for Prefix Adding Allow for Suffix Adding C: Add the prefix and suffixes according to your need (Appendix A) D: Scan “Exit Setting Mode”...
  • Page 94 Appendix A: Barcode Barcode ASCII ASCII space " &...
  • Page 97 < >...
  • Page 100: Reference Charts

    Reference Charts Symbology Charts Linear Symbologies Newtologic Possible Modifiers (m) All Symbologies Codabar Code 11 Code 128 0, 1, 2, 4 Code 32 Pharmaceutical < (PARAF) Code 39 (supports 0, 1, 3, 4, Full ASCII mode) TCIF Linked Code 39 (TLC39) Code 93 and 93i 0-9, A-Z, a-m...
  • Page 101 Possible Symbology Modifiers (m) GS1 DataBar GS1 DataBar Limited GS1 DataBar Expanded GS1-128 2 of 5 China Post (Hong Kong 2 of 0, 1, 3 Interleaved 2 of 5 Matrix 2 of 5 NEC 2 of 5 Straight 2 of 5 IATA 0, 1, 3 Straight 2 of 5 Industrial 0, 1...
  • Page 102: 2D Symbologies

    2D Symbologies Newtologic Possible Symbology Modifiers (m) All Symbologies Aztec Code 0-9, A-C Chinese Sensible Code (Han Xin Code) Codablock A 0, 1, 4, 5, Codablock F 0, 1, 4, 5, 0, 1, 2, 4 Code 49 Data Matrix GS1 Composite DataBar Omnidirecti MaxiCode PDF417...
  • Page 103: Postal Symbologies

    Postal Symbologies Newtologic Possible Symbology Modifiers (m) All Symbologies Australian Post British Post Canadian Post Newtologic Symbology Possible Modifier China Post InfoMail Intelligent Mail Bar Code Japanese Post KIX (Netherlands) Korea Post Planet Code Postal-4i Postnet...
  • Page 104: Ascii Conversion Chart

    ASCII Conversion Chart Char NUL (Null char.) SOH (Start of Header) STX (Start of Text) ETX (End of Text) EOT (End of Transmission) ENQ (Enquiry) ACK (Acknowledgment) BEL (Bell) BS (Backspace) HT (Horizontal Tab) LF (Line Feed) VT (Vertical Tab) FF (Form Feed)...
  • Page 105 $ (Dollar Sign) % (Percent) & (Ampersand) ` (Single Quote) ((Right / Closing Parenthesis) )(Right / Closing Parenthesis) * (Asterisk) + (Plus) ,(Comma) -(Minus / Dash) . (Dot) / (Forward Slash) :(Colon) ;(Semi-colon) (Less Than) < (Equal Sign) (Greater Than) >...
  • Page 106 [ (Left / Opening Bracket) \(Back Slash) ] (Right / Closing Bracket) ^ (Caret / Circumflex) _ (Underscore) ' (Grave Accent)...
  • Page 107 { (Left/ Opening Brace) | (Vertical Bar) } (Right/Closing Brace) ~ (Tilde) DEL (Delete)...
  • Page 108: Sample Symbols

    Sample Symbols UPC-A Interleaved 2 of 5 Code 128 Straight 2 of 5Industrial 123456 Matrix 2 of 5 6543210...
  • Page 109 Code 93 Straight 2 of 5Industrial 123456 GS1DataBar PDF417 Codabar...
  • Page 110 Data Matrix TestSymbol QRCode Numbers Aztec Micro PDF417 MaxiCode Test Message Test Message...
  • Page 111: Programming Charts

    Programming Charts (K0K.) (K1K.) (K2K.) (K3K.) (K4K.) (K5K.) (K6K.) (K7K.)
  • Page 112 (K8K.) (K9K.) (KAK.) (KBK.) (KCK.) (KDK.) (KEK.) (KFK.)
  • Page 113 (800002.) Save (800000.) Discard Note: If an error occurs while scanning a letter or number (before scanning the "Save" barcode), scan the "Discard" barcode, rescan the correct letter or number, and then scan the "Save" barcode.