Precautions Please read everything in the manual carefully before using the product described in this manual, and read the following notes carefully in order to ensure that the bar code scanning equipment according to the design indicators of safe use, please carefully keep the instructions, so that the future at any time to check.
Revision History Date Version Describe 2018-10-20 Initial version Remove invalid content 2018-11-20 Remove the hand-scanned phone 2018-12-15 barcode, add Han XinCode,modify the manual Chinese word description. 2019-03-15 New series of common feature version manual 2019-08-28 Add some suffix samples;add Chinese keyboard 2019-8-31 Format adjustment 2019-11-15...
Foreword Brief Introduction This manual provides bar code scanning equipment Start-up and configuration instructions, as well as maintenance and customer support information. Chapter Outline Chapter 1 Connections and Basic Settings :introduces the method and default settings for bar code scanning devices Chapter 2 Interface Types : Describes the main configuration of interface types Chapter 3 Input / Output Settings: Describes Configuration Decoding Success / Failed LED and Buzzer Response...
Chapter 1 Connection and Basic Settings Introduction The Newtologic barcode scanner supports three connection methods. Please follow the appropriate connection procedure to connect the barcode scanner. Unpacking To open the product packaging, perform the following steps: • Remove the scanner and its accessories and inspect for damage during shipment.
RS232 Connection Connect the device interface (RJ45 connector) of the RS-232 cable to the scanner. Connect the host interface (RS-232 interface) of the RS-232 cable to the host. The barcode scanner is humming. Verify the operation by scanning the Sample Symbols at the end of this manual.
Barcode Reading The barcode scanner has a line of sight/point that projects a red aiming beam that corresponds to the horizontal field of view of the barcode scanner. The line of sight/point should be at the center of the barcode, but it can be positioned in any direction to facilitate reading.
Chapter 2 Interface Type Introduction This chapter introduces the USB and RS232 interface types and lists their related configurations. RS232 Connect RS232 interface, you need to scan the "RS232" barcode, the serial port related configuration is: 9600 baud rate, 8 data bits, no parity, 1 stop bit, add carriage return and line feed by default.
Chapter 3 Data Editing Introduction This chapter describes how to add prefixes and suffixes. • Default prefix = None. Default suffix = None. • A prefix or suffix may be added or cleared from one symbology or all symbologies. • You can add any prefix or suffix from the ASCII Conversion Chart deplus Code I.D.
Add Prefix or Suffix Step 1. Scan the Add Prefix or Add Suffix symbol Step 2. Determine the 2 digit Hex value from the Symbology Chart for the symbology to which you want to apply the prefix or suffix. For example, for Code 11, Code ID is “h”...
Example Add a Suffix to a specific symbology To send a CR (carriage return)Suffix for code 128. only: Step 1. Scan Add Suffix. Step 2. Determine the 2 digit hex value from the Symbology Charts code 128. Step 3. Scan 6, 3 from the Programming Chart inside the back cover of this manual.
To Add a Carriage Return Suffix to All Symbologies Scan the following barcode if you wish to add a carriage return suffix to all symbologies at once. This action first clears all current suffixes, then programs a carriage return suffix for all symbologies. (890000.) Add CR Suffix All Symbologies To Add a Line Break Suffix to All Symbologies...
Clear Prefixes or Suffixes You can clear a single prefix or suffix, or clear all prefixes/suffixes for a symbology. If you have been entering prefixes and suffixes for single sym- bologies, you can use Clear One Prefix (Suffix) to delete a specific char- acter from a symbology.
Function Code Transmit When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Default = Disable. (8080071.) *Enable (8080070.) Disable Intermessage Delay An intermessage delay of up to 5000 milliseconds (in 5ms increments) may be placed between each scan transmission.
Chapter 4 Symbologies Introduction Each type of barcode has its own unique properties. The barcode scanner can be adjusted to accommodate these property changes through the configuration code in this chapter. The fewer the barcode types, the faster the barcode scanner can read. You can disable the barcode scanner to read the barcode types that will not be used to improve the performance of the barcode scanner.
All Symbologies If you want to decode all the symbologies allowable for your scanner, scan the All Symbologies On barcode. If on the other hand, you want to decode only a particular symbology, scan All Symbologies Off followed by the On barcode for that particular symbology. (9990011.) All Symbologies On (9990010.)
1D Barcode If the bar code scanning device needs to decode all the one-dimensional code systems, please scan the bar code of “All 1D Barcode on”. Only solve specific code system, please scan " All 1D Barcode off" . (9950040.) All 1D Barcode on (9950041.) All 1D Barcode off...
Codabar (900000.) Default All Codabar Settings On/Off (9000031.) * On (9000030.) Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters.Default = Don’t Transmit. (9000061.) Transmit (9000060.) * Don’t Transmit Check Character No Check Character indicates that the scanner reads and transmits barcode data with or without a check character.
Page 27
(9000010.) * No Check Character (9000011.) Validate but Don’t Transmit (9000012.) Validate and Transmit...
Concatenation Codabar supports symbol concatenation. When you enable concatena- tion, the scanner looks for a Codabar symbol having a “D” start character, adjacent to a symbol having a “D” stop character. In this case the two mes- sages are concatenated into one with the “D” characters omitted. A 1 2 3 4 D D 5 6 7 8A Select Require to prevent the scanner from decoding a single “D”...
Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-60. Minimum Default = 4, Maximum Default = 60. (900005.) Minimum Message Length (900004.) Maximum Message Length...
Code 39 < Default All Code 39 Settings > (901000.) Default All Code 39 Settings Code 39 On/Off (9010011.) * On (9010010.) Start/ Stop Characters Start/Stop characters identify the leading and trailing ends of the barcode. You may either transmit, or not transmit Start/Stop characters. Default = Don’t Transmit.
Check Character No Check Character indicates that the scanner reads and transmits bar- code data with or without a check character. When Check Character is set to Validate, but Don’t Transmit, the unit only reads Code 39 barcodes printed with a check character, but will not transmit the check character with the scanned data.
Code 39 Append This function allows the scanner to append the data from several Code 39 barcodes together before transmitting them to the host computer. When the scanner encounters a Code 39 barcode with the append trigger char- acter(s), it buffers Code 39 barcodes until it reads a Code 39 barcode that does not have the append trigger.
Code 32 Pharmaceutical (PARAF) Code 32 Pharmaceutical is a form of the Code 39 symbology used by Ital- ian pharmacies. This symbology is also known as PARAF. When you configure code32, you need to turn on code39 before you configure it. (9010051.) (9010050.) * Off...
FULL ASCII If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar- code symbol will be interpreted as a single character. For example:$V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #.
Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings > (902000.) Default All Interleaved 2 of 5 Settings On/Off (9020021.) * On (9020020.) Check Digit No Check Digit indicates that the scanner reads and transmits barcode data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads Interleaved 2 of 5 barcodes printed with a check digit, but will not transmit the check digit with the scanned data.
Page 36
(9020011.) Validate, but Don’t Transmit (9020012.) Validate and Transmit...
Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. (902004.) Minimum Message Length (902003.) Maximum Message Length...
NEC 2 of 5 < Default All NEC 2 of 5 Settings > (903000.) Default All NEC 2 of 5 Settings On/Off (9030011.) * On (9030010.) Check Digit No Check Digit indicates that the scanner reads and transmits barcode data with or without a check digit. When Check Digit is set to Validate, but Don’t Transmit, the unit only reads NEC 2 of 5 barcodes printed with a check digit, but will not transmit the check digit with the scanned data.
Page 39
(9030021.) Validate, but Don’t Transmit (9030022.) Validate and Transmit...
Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-80. Minimum Default = 4, Maximum Default = 80. (903004.) Minimum Message Length (903003.) Maximum Message Length...
Code 93 < Default All Code 93 Settings > (904000.) Default All Code 93 Settings On/Off (9040021.) * On (9040020.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 0-80.
Straight 2 of 5 Industrial (three-bar start/stop) <Default All Straight 2 of 5 Industrial Settings> (905000.) Default All Straight 2 of 5 Industrial (three-bar start/stop)Settings On/Off (9050011.) (9050010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
Straight 2 of 5 IATA (two-bar start/stop) <Default All Straight 2 of 5 IATA Settings> (906000.) Default All Straight 2 of 5 IATA (two-bar start/stop)Settings On/Off (9060011.) (9060010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
Matrix 2 of 5 <Default All Matrix 2 of 5 Settings> (907000.) Default All Matrix 2 of 5 Settings On/Off (9070011.) (9070010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
Check Scan the barcode below to enable or disable the check function of matrix25. (9070051.) Enable Check Function (9070050.) Disable Check Function...
Code 11 <Default All Settings> (908000.) Default All Code 11 Settings On/Off (9080021.) (9080020.) * Off Check Digits Required This option sets whether 1 or 2 check digits are required with Code 11 barcodes. Default = Two Check Digits. (3110280.) One Check Digit (3110281.) * Two Check Digits...
Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 4, Maximum Default = 80. (908004.) Minimum Message Length (908003.) Maximum Message Length...
Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 0-80. Minimum Default = 0, Maximum Default = 80. (909003.) Minimum Message Length (909002.) Maximum Message Length...
GS1-128 <Default All GS1-128 Settings> (910000.) Default All GS1-128 Settings On/Off (9100011.) * On (9100010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-80. Minimum Default = 1, Maximum Default = 80. (910003.) Minimum Message Length (910002.)
Telepen <Default All Telepen Settings> (911000.) Default All Telepen Settings On/Off (9110011.) (9110010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-60. Minimum Default = 1, Maximum Default = 60. (911003.) Minimum Message Length (911002.)
UPC-A <Default All UPC-A Settings> (912000.) Default All UPC-A Settings (9120031.) * On (9120030.) Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. (9120041.) * On (9120040.)
Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. Default = On. (9120051.) * On (9120050.) Addenda This selection adds 2 or 5 digits to the end of all scanned UPC-A data.
Addenda Required When Required is scanned, the scanner will only read UPC-A barcodes that have addenda. You must then turn on a 2 or 5 digit addenda. Default = Not Required. (9120061.) Required (9120060.) * Not Required Addenda Separator When this feature is on, there is a space between the data from the barcode and the data from the addenda.
UPC-E0 <Default All UPC-E Settings> (914000.) Default All UPC-E0 Settings On/Off Most U.P.C. barcodes lead with the 0 number system. To read these codes, use the *UPC-E0 On selection. If you need to read codes that lead with the 1 number system, use UPC-E1. Default = On. (9140101.) * UPC-E0 On (9140100.)
Expand UPC-E Expand expands the UPC-E code to the 12 digit, UPC-A format. Default = Off. (9140021.) (9140020.) * Off Addenda Required When Required is scanned, the scanner will only read UPC-E barcodes that have addenda. Default = Not Required. (9140031.) Required (9140030.)
(9140040.) Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not. Default = On. (9140051.) (9140050.)
Number System The numeric system digit of a U.P.C. symbol is normally transmitted at the beginning of the scanned data, but the unit can be programmed so it will not transmit it. To prevent transmission, scan Off. Default = On. (9140061.) * On (9140060.)
UPC-E1 Most U.P.C. barcodes lead with the 0 number system. For these codes, use UPC-E0. If you need to read codes that lead with the 1 number system, use the UPC-E1 On selection. Default = Off. (9140091.) UPC-E1 On (9140090.) EAN/JAN-13 * UPC-E1 Off <Default All EAN/JAN Settings>...
Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. (9150021.) * On (9150020.) Addenda This selection adds 2 or 5 digits to the end of all scanned EAN/JAN-13 data. Default = Off for both 2 Digit and 5 Digit Addenda.
Addenda Required When Required is scanned, the scanner will only read EAN/JAN-13 barcodes that have addenda. Default = Not Required. (9150051.) Required (9150050.) * Not Required Addenda Separator When this feature is On, there is a space between the data from the barcode and the data from the addenda.
EAN/JAN-8 <Default All EAN/JAN-8 Settings> (916000.) Default All EAN/JAN-8 Settings On/Off (9160011.) * On Check Digit (9160010.) This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not. Default = On. (9160021.) * On (9160020.)
(9160031.) 2 Digit Addenda On (9160030.) * 2 Digit Addenda Off (9160041.) 5 Digit Addenda On (9160040.) * 5 Digit Addenda Off Addenda Required When Required is scanned, the scanner will only read EAN/JAN-8 barcodes that have addenda. Default = Not Required. (9160051.) Required (9160050.)
Addenda Separator When this feature is On, there is a space between the data from the barcode and the data from the addenda. When turned Off, there is no space. Default = On. (9160061.) * On (9160060.)
Check Characte MSI barcodes use different types of check characters. You can configure the barcode scanner to read the MSI barcode using the check character. Default = Validate MOD 10, but Don’t Transmit When Check Character is set to Validate MOD 10 and Transmit, the scanner will only read MSI barcodes printed with the specified type check character(s), and will transmit the character(s) at the end of the scanned data.
GS1 DataBar Expanded < Default All GS1 DataBar Expanded Settings > (920000.) Default All GS1 DataBar Expanded Settings On/Off (9200011.) * On (9200010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 4-74.
PDF417 < Default All PDF417 Settings > (924000.) Default All PD417 Settings On/Off (9240011.) * On (9240010) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-2750. Minimum Default = 1, Maximum Default = 2750. (924003.) Minimum Message Length (924002.)
QR Code < Default All QR Code Settings > (928000.) Default All QR Code Settings On/Off This selection applies to both QR Code and Micro QR Code. (9280011.) * On (9280010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
Data Matrix < Default All Data Matrix Settings > (930000.) Default All Data Matrix Settings On/Off (9300011.) * On (9300010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-3116.
Aztec Code < Default All Aztec Code Settings > (931000.) Default All Aztec Code Settings On/Off (9310011.) * On (9310010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-3832.
China Post (Hong Kong 2 of 5) <Default All China Post (Hong Kong 2 of 5) Settings> (936000.) Default All China Post (Hong Kong 2 of 5)Settings On/Off (9360011.) (9360010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information.
Korea Post <Default All Korea Post Settings> (937000.) Default All Korea Post Settings On/Off (9370011.) (9370010.) * Off Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 2-80.
Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data. Default = Don’t Transmit. (9370041.) (9370040.) * Off Han Xin Code <Default All Han Xin Code Settings> (932000.) Default All Han Xin Code Settings On/Off (9320011.)
Page 76
(932003.) Minimum Message Length (932002.) Maximum Message Length...
Codablock A <defalt all composites settings> (922000.) On/Off (9220011.) (9220010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-600. Minimum Default = 1, Maximum Default = 600. (922003.) Minimum Message Length (922002.)
Codablock F <defalt all composites settings> (923000.) On/Off (9230011.) (9230010.) Message Length Scan the barcodes below to change the message length. Refer to Message Length Description for additional information. Minimum and Maximum lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048. (923003.) Minimum Message Length (923002.)
Chapter 5 Utilities Show Software Revision Scan the barcode below to output the current software revision, unit serial number, and other product information. (809005.) Show Revision...
Chapter 6 Common Problems And Solutions Problem: The barcode scanner does not work. possible reason: 1. The barcode scanner is not powered, check the power of the equipment. If you are using an incorrect cable, use the cable that was originally configured. The cable interface is loose and reconnected.
Chapter 7 Maintenance And Customer Service Maintenance Stains and dust on the scanning window can sometimes affect the normal operation of the barcode scanner. When cleaning, use a good quality tissue to wipe gently, or use a soft cloth to clean. If you use a paper with poor paper quality for a long time, it will damage the surface finish of the window and affect the reading effect of the barcode scanner.
Chapter 8 Bluetooth bar code description Sound related settings Mute Enter setting mode: Low volume: Exit setting mode: Medium volume: Display version information: High volume: Restore default settings: International keyboard: Buzzer frequency 2K: Enter normal mode: Compulsory pairing with Dongle: Enter inventory mode:...
Page 86
Never sleep: Display total storage entries: Hibernate now: Clear inventory data: Sleep time 30S: Fast transmission: Fast transmission: Sleep time 1 minute: Low-speed transmission: Sleep time 2 minutes: Ultra low speed transmission: Sleep time 5 minutes: 2.4G mode: Sleep time 10 minutes: Turn off double-click to pop up/hide the HID keyboard: Sleep time 30 minutes:...
example: 1. 2.4G mode After plugging Dongle into the computer and the computer identifying Dongle successfully, pls. scan “Enter Settings”-“2.4G Mode”-“Connect Dongle”-“Exit Settings” in sequence to pair. After connect successfully, the blue colored lights will be on. (Note: For the meaning of indicator refer to part 7) ①Enter settings ②2.4G Mode...
Page 88
3. Function configuration 3.1.Configure carriage return (CR) line feed (LF) Scan “Enter Settings” to start functional setting. To scan one of the functional barcode below as you needed, then need to scan “Exit Settings” to complete the functional setting Enter settings Add CR suffix Add LF suffix Add CR+LF suffix...
Page 89
5. Pull up and hide keyboards in Android, iOS operating system device (Bluetooth Function) A: Start the scanner, scan “Enter Setting Mode” barcode. Enter Settings B: Scan the codes below to pull up or hide the iOS keyboard Pull up or hide iOS keyboard Trigger twice to pull up iOS keyboard Trigger twice to disable iOS keyboard C.
Page 90
6.Communication mode switching (Optional) A:Start the scanner, scan “ Enter Setting Mode” barcode. Enter Settings B : Select the communication mode barcode according to your need. 2.4G Wireless Mode Bluetooth HID Mode Bluetooth SPP Mode Bluetooth BLE Mode C : Scan “Exit Setting Mode” barcode Exit Settings...
Page 91
7. Language Settings A:Switch on the scanner and scan “Enter Setting Mode” barcode Enter Settings B: Select your intended keyboard language English Germany French Spanish Italian Japanese For PC termninal only, American keyboard language output C : Scan “Exit Setting Mode” barcode Exit Settings...
Page 92
8. Remove prefix and suffix setting A:Start the scanner and scan “Enter Setting Mode” barcode Enter Settings B: Scan "Remove Prefix", "Remove Suffix" barcode Remove Prefix Remove Suffix C: Scan the barcode according to your need to remove the bits Remove 1bit Remove 2bits Remove 3bits...
Page 93
9. Prefix and Suffix Setting A:Start the scanner and scan “Enter Setting Mode” barcode Enter Settings B: Scan the "Allow for Prefix Adding" or "Allow for Suffix Adding" setting barcode Allow for Prefix Adding Allow for Suffix Adding C: Add the prefix and suffixes according to your need (Appendix A) D: Scan “Exit Setting Mode”...
Reference Charts Symbology Charts Linear Symbologies Newtologic Possible Modifiers (m) All Symbologies Codabar Code 11 Code 128 0, 1, 2, 4 Code 32 Pharmaceutical < (PARAF) Code 39 (supports 0, 1, 3, 4, Full ASCII mode) TCIF Linked Code 39 (TLC39) Code 93 and 93i 0-9, A-Z, a-m...
Page 101
Possible Symbology Modifiers (m) GS1 DataBar GS1 DataBar Limited GS1 DataBar Expanded GS1-128 2 of 5 China Post (Hong Kong 2 of 0, 1, 3 Interleaved 2 of 5 Matrix 2 of 5 NEC 2 of 5 Straight 2 of 5 IATA 0, 1, 3 Straight 2 of 5 Industrial 0, 1...
Postal Symbologies Newtologic Possible Symbology Modifiers (m) All Symbologies Australian Post British Post Canadian Post Newtologic Symbology Possible Modifier China Post InfoMail Intelligent Mail Bar Code Japanese Post KIX (Netherlands) Korea Post Planet Code Postal-4i Postnet...
Page 113
(800002.) Save (800000.) Discard Note: If an error occurs while scanning a letter or number (before scanning the "Save" barcode), scan the "Discard" barcode, rescan the correct letter or number, and then scan the "Save" barcode.
Need help?
Do you have a question about the SG-110-BT and is the answer not in the manual?