Download Print this page

Maintenance - Sealey ECS300.V2 Manual

Electronic starter / charger / maintainer 300/45a 12/24v

Advertisement

- Charge 120Ah/200Ah: Charge for batteries with capacity from 120Ah to 200Ah.
- Charge 4Ah/450Ah:
Adjust the output current from 0 up to the maximum supported by the operating mode currently selected on the
charger using the dial on the right of the panel.
• Type key: Depending on the construction/type of the battery, select: Wet or Agm/Spiral Cell.
7.2.4.
Once the charging parameters haver been set, press the START/STOP key to start charging the battery. When the START/STOP and
CHARGING LEDs light up, the battery is being charged; the display will show the charging current and the voltage of the battery.
7.2.5.
The CHARGING LED remains lit in phases "I" and "U0" whilst the battery is charging.
7.2.6.
When the FULL LED switches on, it means that the battery is fully charged (100%) and the charger will switch to the maintenance
phase, keeping the state of efficiency of the battery constantly monitored so that it is always at an optimal level of charge. In this
charging phase, the appliance can be left connected to the battery for several months.
7.2.7.
If you wish to end or interrupt the charging cycle, follow the end of charging instructions in section 7.5.
7.3.
INTENTIONAL INTERRUPTION OF THE CHARGING CYCLE
7.3.1.
If you want to interrupt the battery charging cycle, simply press the START/STOP key; the corresponding LED will switch off to
show that the work cycle has ended. At this stage, it is recommended to disconnect the output leads from the battery terminals/
earthing point.
7.4.
INTERRUPTION OF THE CHARGING CYCLE IN THE CASE OF A POWER SUPPLY CUT
7.4.1.
In the case of a mains power supply cut, the charger saves the work cycle that it was performing in order to restore it automatically
as soon as the power supply is restored.
7.4.2.
This function is fundamental if the battery charger is used to charge batteries without the operator supervising the cycle; for
example, during very long charging cycles (charge maintenance) or when charging overnight (charges for vehicles that need to be
charged daily).
7.5.
END OF CHARGING
7.5.1.
Once the battery is charged, unplug the power supply lead of the charger from the mains supply.
7.5.2.
Disconnect the output lead with the black clamp from the negative terminal (-) of the battery or from the vehicle's earthing point.
7.5.3.
Disconnect the output lead with the red clamp from the positive terminal (+) of the battery. Store clamps properly on the charger.
7.6.
STARTING A VEHICLE
7.6.1.
Connect the charger to the vehicle as in section 7.1.1. to 7.1.4. above, and connect the charger to the mains supply as in 7.2.1.
above.
7.6.2.
Select Start and also the correct battery type and battery capacity using the selection buttons on the control panel.
7.6.3.
Press the Start button and the Start LED will flash for a while (analysis), and then will remain on (fast charging). Engine starting can
now be attempted.
7.6.4.
Attempt to start the engine - the scrolling message START appears on the display - if the engine doesn't start within 5 seconds,
stop cranking the engine and wait for 120 seconds before attempting again. A maximum of 5 cycles of starting/resting is OK, before
a longer rest period is needed before attempting again. This is important as the charger needs a cooling down period.
7.6.5.
When the engine starts, switch off the charger and remove the clamps from the battery in the order as in section 7.5. above.

8. MAINTENANCE

8.1.
When the battery charger is not being used, it must be stored in a dry place to protect it against humidity.
Use a soft cloth to clean its outer casing.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic
Equipment (WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way.
Contact your local solid waste authority for recycling information.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 24 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
Supports all batteries from a minimum capacity of 4Ah up to a maximum of 450Ah.
sales@sealey.co.uk
Original Language Version
REGISTER YOUR
PURCHASE HERE
www.sealey.co.uk
ECS300.V2 Issue 2 (2) 15/01/24

Advertisement

loading