Summary of Contents for Fluigent FLOW UNIT

  • Page 1 USER’S MANUAL FLOW RATE PLATFORM FLOW UNIT / FLOW UNIT+ MARCH 2024...
  • Page 2: Table Of Contents

    CLEANING PROCEDURE in all configurations and to comply with all safety standards. The diameter of the FLOW UNIT XS capillary is small: 25 m. Filter your solution, if possible add a filter in the fluidic path and clean the FLOW UNIT XS after each use.
  • Page 3: Introduction

    This user manual will show you how to install and use flow units in your daily work. It will describe all the Flow unit functionalities and will help you to connect all the different FLOW UNIT models and to use it with all the equipment: with Fluigent Flow EZ and MFCS This user manual will show you how to install and use flow units in your...
  • Page 4 flow control solutions (FLOW EZ™ and MFCS™-EZ). More details on applied to a FLOW UNIT does not go beyond this value at all times. The FLOW UNIT suits your own fluid controller. If you use a pressure regulator you may have to enter a www.fluigent.com.
  • Page 5: Flow Unit Description

    fluidic connection system fits with the two (2) fluidic ports for water and Isopropyl alcohol of the FLOW UNIT. If not, please note that there is a large panel of The back of the FLOW UNIT also displays information about the range adapters and unions to connect your tubings to ours.
  • Page 6 firmly against the bottom of the port, tighten the fitting finger that your fluidic connection system fits with the two (2) fluidic ports of the FLOW UNIT. If not, please note that there is a large panel of tight.
  • Page 7: Setting Up With Flow Ez

    firmly against the bottom of the port, tighten the nut finger tight.. To check the tightness of your connection, you may pull gently on Combined with FLOW UNIT it allows access in real time flow rate the tubing: it must stay fitted in the ferrule and nut.
  • Page 8 For connection of FLOW UNIT to Flow EZ simply connect the USB cable from the FLOW UNIT to the Flow EZ Once a FLOW UNIT is connected, the device automatically detects it and the "Operation window" will display an additional zone including the flow rate measurement.
  • Page 9: Ogen

    µL/min Set P Ctrl Menu The Link module must be connected to the Flow EZ first. When the Link is connected to the Flow EZ, coneect the Flow unit to Measured flow rate units the Flow EZ. displayed can be chosen...
  • Page 10 . If Flow rate control is needed it’s possible to click For more detailed information please see the Oxygen user on the Hand icon to launch the DFC (Direct flow control mode). manual in the following link: https: //www.fluigent.com/ resources-support/support-tools/downloads/user-manuals/...
  • Page 11: Setting Up With Flowboard

    SETTING UP WITH FLOWBOARD When air is detected, red aeras will be displayed on the flowgraph For the use of our FLOW UNIT sensor range without Flow EZ over the period of detection. Flowboard is a product that must be used. This device hosts up to eight (8) FLOW UNIT models and provides them power supply.
  • Page 12: C F

    FLOW UNIT connection To connect a FLOW UNIT to the FLOWBOARD, plug the end of the mini-USB plug fixed with the FLOW UNIT to one of the eight (8) mini- USB ports on the FLOWBOARD. First, you may want to integrate the different FLOW UNIT to your microfluidic system, with the right fittings.
  • Page 13 For more detailed information please see the Oxygen user the “Order” field. The name of the channel (that can be modified) and manual in the following link: https: //www.fluigent.com/ its characteristics can be seen in the top right corner. resources-support/support-tools/downloads/user-manuals/...
  • Page 14: Dual Calibration

    The different FLOW UNIT models are calibrated to provide an accurate reading when used with the corresponding fluid, water or isopropyl alcohol. For the FLOW UNIT model XS, only one single calibration for water is available. For the FLOW UNIT models S/M+/L+, two calibrations are available: Water and Isopropyl alcohol.
  • Page 15 The list of materials needed to reproduce the experiment is given Make a table that contains the time for each measurement, the flow- below: rate of the pump and the data measured by the FLOW UNIT. One (1)FLOW EZ™ A minimum of 3 measurements is recommended for each flow-rate.
  • Page 16: Cleaning Procedure

    4.68 so that the measurement of the sensor corresponds to the actual flow-rate for HFE. FLOW UNIT models are highly sensitive and should be properly cleaned to always maintain high performance. With proper This custom calibration can be directly implemented on OxyGEN care and maintenance, the Flow Units can last many years.
  • Page 17 For Flow Unit XS, S and M, fluids have to be compatible with PEEK & If possible, dedicate a separate sensor for each different liquid to be Quartz glass.
  • Page 18 If uncertain about your application and how to clean the flow sensor, damage the sensor. please contact FLUIGENT for additional support at support@fluigent. com. Strong acids and bases should also not be used to clean the sensor. Acids can sometimes be used in low concentration and at low temperatures.
  • Page 19: Servicing & Warranty

    - Filter your solution, if possible add a filter in the fluidic path (§ 10) and clean your FLOW UNIT after each use, especially the FLOW UNIT XS (cf § 4.3). The diameter of the FLOW UNIT XS capillary is small: 25 m. Fluigent rejects any What This Warranty Covers liability in the event of clogging or surface modifications.
  • Page 20 VERSION SEP. 2022...