Summary of Contents for Dimplex XPELAIR XIMX+ Series
Page 1
IN-LINE MIXED-FLOW FANS XIMX+ U S E R ' S M A N U A L...
Page 2
ATTENTION Deenergize the fan power circuit prior to all connection, adjustment, servicing and repair operations. Mounting and maintenance are allowed by duly qualified electricians with valid electrical work permit for electric operations at the units up to 1000 V after careful study of the present user's manual. The single-phase power grid must comply with the acting local electrical norms and standards.
Read the present user's manual carefully before proceeding with installation works. Compliance with the manual requirements ensures reliable operation and long service life of the product. Keep the user's manual available as long as you use ATTENTION the product. You may need to re-read the information on the product servicing. DELIVERY SET The delivery set includes: 1.
OPERATION RULES The fan is rated for connection to single-phase 220-240 V / 50/60 Hz power mains. The fan is designed for continuous operation always connected to power mains. Air motion direction in the system must match the pointer on the fan casing. Ingress protection rating IP X4.
Page 5
MOUNTING The fan is suitable both for horizontal or vertical mounting on the floor, on the wall or on the ceiling (fig. 2) as one unit or included into connected in parallel or in series sets (fig. 3). In case of the horizontal fan mounting install a straight air ducts segment on side of the intake vent not less than 1 m;...
MAINTENANCE Clean the product surfaces regularly (once in 6 months) from dust and dirt (fig. 35-42). Disconnect the fan from power mains prior to any maintenance operations. To clean the fan use a soft cloth and a brush wetted in a mild detergent water solutions. Avoid water dripping on the electric components (fig.
Page 7
With the purpose of performing warranty servicing please contact the trade company where you purchased the product. If warranty servicing on the spot proves impossible, you will be provided with the necessary information regarding rendering of this service. Manufacturer's warranty shall not apply in the following cases: - in case the customer fails to provide the product in complete according to the package contents specified in the User Manual or other relevant substituting document, including any components disassembled by the customer;...
Page 8
The manufacturing company shall be responsible for defects arising through its fault prior to the moment of transferring the product to the ownership of the customer. The manufacturing company shall not be responsible for defects arising after transferring the product to the customer and caused by the customer's violating the rules of transportation, storage, assembly and operation of the product, or by actions of third persons, an accident or force majeure circumstances.
Page 13
XIMX100+ T terminal block for 4 contacts terminal block for 5 contacts terminal block for 4 contacts MAX / MIN terminal block for 5 contacts terminal block for 5 contacts terminal block for 4 contacts...
Page 56
ACCEPTANCE INFORMATION Fan is ready for using. Acceptance stamp Date of production Sold (name of trade enterprise and stamp of the shop) Date of sale Xpelair Newcombe House Newcombe Way Orton Southgate Technical: 0844 372 7766 Peterborough Sales: 0844 372 7750 www.xpelair.co.uk PE2 6SE...