IDMHDV-120 Lever Operated Diaphragm Valve User Manual www.intertronics.co.uk/idmhdv-120 Station Field Industrial Estate Banbury Road, Kidlington Oxfordshire, England OX5 1JD t 01865 842842 e info@intertronics.co.uk www.intertronics.co.uk...
Page 2
IDMHDV-120 Lever Operated Handheld Diaphragm Valve User Manual Thank you for purchasing the IDMHDV-120 Lever Operated Diaphragm Valve. For optimum performance and results, please read this manual carefully. Ensure that all operators and personnel are adequately trained for use with this product.
IDMHDV-120 Lever Operated Handheld Diaphragm Valve User Manual Table of Contents Theory of Operation..............2 Safety ..................2 Set Up ..................2 Diaphragm Actuation ..............3 Starting Up the Valve ..............3 Shutting Down the Valve ............... 3 Diagram #IDMHDV-120 ............. 4-5 Operation ..................
Refer to the SDS for the material being dispensed for other precautions. Set Up The IDMHDV-120 does not require an air source for actuation, but relies only on the operator to depress a lever to actuate the valve. Constant material pressure is applied to the diaphragm of the valve, which is held in place with the spring-loaded piston.
Starting Up the Valve At the beginning of the day or a shift, set up the IDMHDV-120 to resume normal operation. Remove the luer lock tip cap from the luer lock adapter (9) and discard.
Plastic Luer IDMHDV-120-V300-UV Adapter* Dowel Pin IDMHDV-120-V061 Set Screw IDMHDV-120-V060 Socket Head IDMHDV-120-SH8-32X0.5 Cap Screw * These parts are included in the IDMHDV-120-SP Spare Parts Kit (10 x Diaphragm (IDMHDV-120-V323), 1 x Plastic Luer adapter (IDMHDV-120-V300-UV)). Contact Intertronics to order.
Page 7
IDMHDV-120 Lever Operated Handheld Diaphragm Valve User Manual 56mm 164mm...
IDMHDV-120 Lever Operated Handheld Diaphragm Valve User Manual Shutting Down the Valve At the end of the day or shift, shut down the IDMHDV-120 dispense system in order to keep material from curing inside the valve. Remove the disposable dispense tip from the luer adapter (9) and discard.
IDMHDV-120 Lever Operated Handheld Diaphragm Valve User Manual Unthread and remove the stroke adjustment nut (3) from the piston (4) which will allow the piston and spring (8) to slide out through the bottom of the top cap (1). Using a .050” Allen key, unthread and remove the two set screws (11) that thread into the standoffs (6).
IDMHDV-120 Lever Operated Handheld Diaphragm Valve User Manual Troubleshooting Problem Possible Cause Corrective Action • Increase fluid pressure Valve does not • Fluid pressure too low above 15psi cycle • Worn diaphragm • Replace diaphragm • Replace diaphragm • Worn diaphragm Material leaks •...