IDMHDV-130 Handheld Diaphragm Valve User Manual Thank you for purchasing the IDMHDV-130 Handheld Diaphragm Valve. For optimum performance and results, please read this manual carefully. Ensure that all operators and personnel are adequately trained for use with this product. This document is based on information available and correct at the time of publication. The statements, technical information and recommendations contained herein are based on knowledge we believe to be reliable but they are not to be construed in any manner as warrantees expressed or implied.
IDMHDV-130 Handheld Diaphragm Valve User Manual Table of Contents Theory of Operation ..............2 Air Section ................2 Fluid Section ................2 Safety ..................2 Set Up ..................3 Diagram #IDMHDV-130 ............. 4-5 Operation ..................6 Routine Cleaning and Disassembly ..........6 General Assembly ................
IDMHDV-130 Handheld Diaphragm Valve User Manual Theory of Operation The IDMHDV-130 is an all-plastic handheld dispense valve that uses a unique rigid diaphragm design to act as a front closing valve to accurately dispense small dots and fine beads. This valve is designed for handheld applications, to take the place of traditional syringe dispensing or other manually applied fluids.
A spring is then used to return the valve to the closed position. A quick connect air fitting is typically supplied with the IDMHDV-130 to fit 5/32” tubing. Fluid is supplied to the IDMHDV-130 through the 1/8” NPT port located on the acetal fluid section of the valve.
IDMHDV-130-VLV-016K Nitrile O-Ring* IDMHDV-130-VLV-007B * These parts are included in the IDMHDV-130-SP Spare Parts Kit (1 x Diaphragm (IDMHDV-130-114-9539), 1 x Nitrile O-Ring (IDMHDV- 130-VLV-116B), 1 x FFKM O-Ring (IDMHDV-130-VLV-016K), 1x Nitrile O-Ring (IDMHDV-130-VLV-007B) and 1 x Plastic Luer adapter (IDMHDV-...
Page 7
IDMHDV-130 Handheld Diaphragm Valve User Manual...
Routine Cleaning and Disassembly Cleaning and rebuilding the valve will be required from time to time. A spare parts kit (IDMHDV-130-SP) is available with all the normal wear parts included (1 x Diaphragm (IDMHDV-130-114-9539), 1 x Nitrile O-Ring (IDMHDV-130-VLV-116B), 1 x FFKM O-Ring (IDMHDV-130-VLV-016K), 1x Nitrile O-Ring (IDMHDV-130-VLV-007B) and 1 x Plastic Luer adapter (IDMHDV-130-V300-UV)).
IDMHDV-130 Handheld Diaphragm Valve User Manual Remove the cylinder cap (7) and stroke adjustment assembly (8, 9) from the air cylinder (6) to remove the spring (12). Insert a flat head screwdriver into the slot of the piston (5) to hold it in place then spin the diaphragm (2) counter-clockwise to unthread it from the piston.
IDMHDV-130 Handheld Diaphragm Valve User Manual Troubleshooting Problem Possible Cause Corrective Action Air pressure to air section is • Increase pressure • too low between 50-80 psi Stroke adjustment bolt is • Back out stroke adjustment bolt • Valve does...