Hide thumbs Also See for EV1:

Advertisement

Quick Links

USER MANUAL
Version 2.1
www.promotion.fitness

Advertisement

Table of Contents
loading

Summary of Contents for ProMOTION EV1

  • Page 1 USER MANUAL Version 2.1 www.promotion.fitness...
  • Page 2: Table Of Contents

    ProMOTION ® User Manual CONTENTS ProMOTION EV1 Wellness Device ® Product Specifications Classification Warnings Contraindications Device Overview Using Your ProMOTION EV1 device ® Menu Overview ProMOTION EV1 App ® Cleaning, Maintenance & Storage Troubleshooting...
  • Page 3: Promotion Ev1 Wellness Device

    The ProMOTION EV1 is a therapeutic product designed to assist a user’s ® lifestyle, combining thermal and compression therapies for key muscle sets and skeletal joints, for use by individuals undertaking sports and general exercise.
  • Page 4: Classification

    ProMOTION® EV1 User Manual CLASSIFICATION This equipment has been tested and complies within the limits for household and similar electrical devices in EN 60335-1:2012/A11:2014 and EN 60335-2- 32:2003/A2:2015 Low Voltage Directive (LVD 2014/35/EU). These standards specify the general requirements and conditions to test the domestic safety...
  • Page 5 ProMOTION User Manual ® CLASSIFICATION Ingress Protection Note that this is a general-purpose product with minimal protection against water. Always keep the device dry. Flammable Anaesthetics or Oxygen The product is not suitable for use in an oxygen enriched environment or in the presence of flammable anaesthetics.
  • Page 6: Warnings

    Swellaway Ltd. Improper placement or prolonged use of the device could result in damage. Do not cover the air vents of the ProMOTION® EV1 device. This may cause the device to overheat. If during use the cooling fan stops, or you suspect any other component failure, cease use and remove the product immediately and contact Swellaway Ltd.
  • Page 7: Contraindications

    Not for use by children. Persons insensitive to heat must be careful when using the appliance. CONTRAINDICATIONS The ProMOTION® EV1 is not intended or designed for medical purposes Caution: Compression therapy using the ProMOTION® EV1 device should not be used by persons: •...
  • Page 8 Caution: Cooling Therapy with the ProMOTION® EV1 device should be used only under the supervision of a licensed healthcare practitioner on users:...
  • Page 9: Device Overview

    User Manual DEVICE OVERVIEW The ProMOTION EV1 pack includes the following items; a user manual, a ® Therapy unit, a Pump unit, two batteries, an AC charging adaptor, a SM/MD Compression wrap, a MD/LG Compression wrap and a universal strap.
  • Page 10 Therapy Unit The ProMOTION ® EV1 Therapy Unit features a multifunction interactive keypad and LCD display. The keypad can be used to power the unit on, select a program mode, start or stop a program and to power the unit down.
  • Page 11 ProMOTION User Manual ® DEVICE OVERVIEW Next menu (Up) Power ON / OFF Go back / Select menu Next menu (Down)
  • Page 12 User Manual ® DEVICE OVERVIEW Pump Unit The ProMOTION EV1 Pump Unit features a USB connector and clip for ® connection to the Therapy Unit. It also features a bayonet fitting for connection to the Compression Wrap. connection Bayonet fitting...
  • Page 13 User Manual ® DEVICE OVERVIEW Battery The ProMOTION EV1 battery features a battery level indicator and button, ® charging port, and eject tab. Depressing the indicator button will result in the level of charge being indicated. • 1 LED = 0 - 25% charge •...
  • Page 14 ® Therapy Unit and Pump Unit. The wraps also feature an adjustment array and handle for adjusting the wrap to suit. Note that two sizes of wrap are supplied with the ProMOTION EV1 system. ® Small / Medium (S/M) and Medium / Large (M/L).
  • Page 15: Using Your Promotion Ev1 Device

    ProMOTION User Manual ® USING YOUR ProMOTION EV1 DEVICE ® Battery charging and usage The battery should be fully charged before use to ensure maximum performance. Follow the procedure below before using the device. If the battery is installed in the Therapy Unit, lift the eject latch on the...
  • Page 16 ProMOTION User Manual ® USING YOUR ProMOTION EV1 DEVICE ® Connect the charger to the battery charging port, then connect the charger to a mains power supply and turn the supply on. The battery level indicator will light up and sequentially pulse to indicate that charging is in progress.
  • Page 17 ProMOTION User Manual ® USING YOUR ProMOTION EV1 DEVICE ® Battery Installation Orientate the battery with the Therapy Unit. A slot on the battery will align with the corresponding feature inside the Therapy Unit. Alignment slot Push the battery into the Therapy Unit until the battery eject tab clicks, securing the battery in place.
  • Page 18 ProMOTION User Manual ® USING YOUR ProMOTION EV1 DEVICE ® Installing Therapy Unit The Therapy Unit can be used on its own for the application of heating or cooling. If you wish to use compression therapy too, the Therapy Unit should be paired with the Pump Unit and Compression wrap.
  • Page 19 ProMOTION User Manual ® USING YOUR ProMOTION EV1 DEVICE ® Installing Pump Unit The Pump Unit attaches to the Compression wrap via a simple bayonet fitting. To attach it: Align the Pump Unit with the port on the cradle. Align the pips on each component (see image below).
  • Page 20 ProMOTION User Manual ® USING YOUR ProMOTION EV1 DEVICE ® Installing Pump Unit Continue to rotate the Pump Unit, until it is in line with the Therapy Unit. Push the Pump unit cable and clip into the USB port on the Therapy Unit until it clicks into place.
  • Page 21 ProMOTION User Manual ® USING YOUR ProMOTION EV1 DEVICE ® Fitting Compression wrap Carefully locate the assembly by placing the Therapy Unit over the injury site. Wrap the Compression wrap comfortably around the limb - It should be secure enough not to slip, but not tight.
  • Page 22 Start with the strap loose and whilst holding the EV1 therapy unit in position, use VELCRO® hook tab to adjust the strap tension to suit. For the long strap, adjust the buckle to the general length, but the final tensioning should be done with the VELCRO®...
  • Page 23 ® Powering up and using the device The ProMOTION EV1 device is now ready for use. Use the keypad to turn ® the device on, navigate the menus, and turn the device off again. Press the ‘Select’ button to power the Therapy Unit on.
  • Page 24 ProMOTION User Manual ® USING YOUR ProMOTION EV1 DEVICE ® Powering up and using the device Once you have selected a program, press ‘Select’ to begin. A timer will appear in the display counting down the time to program completion, while the keypad will light up blue or red depending on the chosen temperature.
  • Page 25 ProMOTION User Manual ® USING YOUR ProMOTION EV1 DEVICE ® Powering down Press and hold the ‘Select’ button to turn the Therapy Unit off. Select next menu (Up) Power ON / OFF Go back / Select menu Select next menu (Down)
  • Page 26 ProMOTION User Manual ® USING YOUR ProMOTION EV1 DEVICE ® Removing the pump and therapy unit Precautions Do not attempt to remove the wrap while it is inflated. Wait a few seconds after the device has switched off to allow the air pressure to drop.
  • Page 27: Menu Overview

    User Manual ® MENU OVERVIEW The ProMOTION EV1 menu system enables users to create and repeat new ® therapy programs, and access pre-designed routines. Use the keypad to navigate to each menu. Pressing the up or down keys will adjust the setting. Once you are happy with your choice, press ‘Select’ - the device will retain your input.
  • Page 28 ProMOTION User Manual ® MENU OVERVIEW Programs Selecting ‘Programs’ allows you to access pre-defined programs, such as those created by a Physiotherapist or other Healthcare professional. Padlock (closed) - Device in use During a program, this screen in displayed. Press and hold ‘Go back’...
  • Page 29 ProMOTION User Manual ® MENU OVERVIEW New - Selecting ‘New’ will create a new program, where temperature, program duration and compression levels can be amended to suit. Use the keypad to navigate to each menu (Temperature, Duration, Compression). Press ‘Up’ or ‘Down’ to adjust the setting.
  • Page 30 History - Selecting ‘History’ gives access to the last 10 previously completed programs. Note that the ProMOTION ® EV1 App gives further access - up to 100 programs. Pressing ‘Up’ or ‘Down’ allows the user to view the program details.
  • Page 31 Failure to follow the set-up instructions properly may result in inadequate therapy. Ensure all components are present before use. Power the Therapy Unit down before removing it from the cradle. It is recommended that the ProMOTION EV1 device is disassembled ®...
  • Page 32: Promotion Ev1 App

    Apple App Store: on Google Play: The ProMOTION EV1 App allows the user to create and store customised ® therapy programs, targeting specific temperature zones or compression levels, and also giving the user the ability to create and use contrast therapy cycles.
  • Page 33 ProMOTION EV1 APP ® Default Programs The ProMOTION EV1 device and app allocates ten program slots. Three of ® these are default programs created by ProMOTION EV1, the rest are available ® for users to create their own programs for use at a later date. Programs created here are automatically saved when you initiate them.
  • Page 34 Create the parameters of the program. Press ‘Select’ to start your program. Program History The ProMOTION EV1 App allows you to access the last 100 program logs ® used by the device. To access the list of programs. Select ‘Program History’.
  • Page 35: Cleaning, Maintenance & Storage

    Do not use any solvent-based cleaners or abrasive materials. Examine the device frequently. Caution: The ProMOTION EV1 is not a waterproof device. Do not apply a ® direct stream of any liquid onto the device, submerge it, or allow any liquid to pool on the device.
  • Page 36 • Store the battery with charge for optimum life. Do not store the battery in a discharged condition. Precautions • It is recommended that the ProMOTION EV1 device is used at Tropospheric ® Pressure levels (1.075 Bar). The device should not be used on an aircraft.
  • Page 37: Troubleshooting

    • Check that the Pump Unit is correctly mounted to the cradle. The Pump should fit parallel with the bayonet • Pump Unit or fan may be damaged - please contact ProMOTION ® Customer services Compression Wrap •...
  • Page 38 ProMOTION® EV1 User Manual...
  • Page 39 Email: customerservices@swellaway.com www.promotion.fitness/resources...
  • Page 40 www.promotion.fitness...

Table of Contents