Guide to diagnostics of NEW COLLECTION EWM09312 electronic controls
E23

E23: Problems with the component (triac) controlling the drain pump

E23
!
Check that all the connectors are correctly inserted
Is the resistance
Is the resistance
measurement of the pump
Replace the pump and repeat
measurement of the pump
approximately 155÷182 Ω?
the diagnostic cycle to check
NO
approximately 155÷182 Ω?
NO
(Measure it between
for any further alarms.
(Measure it directly on the
connectors J5-4 and J5-5 on
pump) –(see fig. 5)–
the board side –(fig. 4)–
YES
YES
Check/replace the wiring and repeat the diagnostic cycle
to check for any further alarms.
Measure it between connectors J5-4/J5-5 and
Replace the main circuit board and repeat the
the appliance body. –(fig. 6)–
NO
diagnostic cycle to check for any further alarms.
Is there any dispersion?
YES
Check/replace the wiring and repeat the
diagnostic cycle to check for any further alarms.
If there are burns on the circuit board,
!
see page 59
T.S.-mdm FCPD-dp Quality tb
24/61
599 74 42-27 Rev.00