BEFORE CONNECTION
• Check whether your oven has suffered any damage during transport (deformed door or
door seal, etc.). If you see any signs of damage, contact your dealer before use.
• Verify the power voltage. If there is a PERMANENT undervoltage (200-210 volts), consult your
electrical installer.
LOCATION
• Refer to the installation instructions furnished with the microwave oven.
• The oven must be set on a work surface at least 85 cm above floor level.
• Place the oven on a flat and horizontal surface, away from any source of heat or steam.
•Make sure that air may circulate freely around the oven.
• Allow nothing to obstruct the ventilation
louvers at the back of the appliance.
• Make sure the electrical plug will be accessible after installation.
ELECTRICAL CONNECTION
• Your installation must be protected by a 16 Amp thermal fuse.
• It is mandatory to use a power point with a ground terminal, connected in accordance with
current safety regulations.
• In your electrical installation, provide a device that is accessible to the installer, capable of
separating the appliance from the mains power and whose contact opening is at least 3 mm
at all of the poles.
• Never operate the oven if the supply cord and/ or its plug are damaged. In case of damage,
call in a specialised technician trained by the manufacturer.
Installation