Refrigent Piping Connection 2 - Midea MFCA26VA-N User Manual

Table of Contents

Advertisement

Refrigerant Piping Connection
Piping Connection Precautions
1
WARNING
WHEN CONNECTING REFRIGERANT PIPING, DO NOT LET SUBSTANCES OR
GASES OTHER THAN THE SPECIFIED REFRIGERANT ENTER THE UNIT. THE
PRESENCE OF OTHER GASES OR SUBSTANCES WILL LOWER THE UNIT'S
CAPACITY, AND CAN CAUSE ABNORMALLY HIGH PRESSURE IN THE
REFRIGERATION CYCLE. THIS CAN CAUSE EXPLOSION AND INJURY.
Note on Pipe Length
The length of refrigerant piping will a ect the performance and energy e ciency of the unit. Nominal
e ciency is tested on units with a pipe length of 5 meters (16.5ft). ( In North America, the standard pipe
length is 7.5m (25'). For the R290 refrigerant models, no refrigerant can be added and the maximum
length of refrigerant pipe should not exceed 5 meters(16.5ft).A minimum pipe run of 3 metres is
required to minimise vibration & excessive noise. Connection Instructions – Refrigerant Piping.
Maximum Length and Drop Height of Refrigerant Piping per Unit Model
Model
R410A,R32 Inverter
Split Air Conditioner
R22 Fixed-speed
Split Air Conditioner
R410A, R32 Fixed-speed
Split Air Conditioner
Connection Instructions – Refrigerant Piping
Step 1: Cut pipes
When preparing refrigerant pipes, take extra
care to cut and flare them properly. This will
ensure efficient operation and minimize the
need for future maintenance.
Measure the distance between the indoor
and outdoor units.
Using a pipe cutter, cut the pipe a little
longer than the measured distance.
Make sure that the pipe is cut at a perfect
90° angle.
DO NOT DEFORM PIPE WHILE CUTTING
Be extra careful not to damage, dent, or deform the pipe while cutting. This will drastically reduce
the heating e ciency of the unit.
Capacity (BTU/h)
< 15,000
15,000 and < 24,000
24,000 and < 36,000
36,000 and < 60,000
< 18,000
18,000 and < 21,000
21,000 and < 35,000
35,000 and < 41,000
< 18,000
18,000 and < 36,000
36,000 and < 60,000
26
Max. Length (m)
Max. Drop Height (m)
25 (82ft)
30 (98.5ft)
50 (164ft)
65 (213ft)
10 (33ft)
15 (49ft)
20 (66ft)
25 (82ft)
20 (66ft)
25 (82ft)
30 (98.5ft)
90°
Oblique
10 (33ft)
20 (66ft)
25 (82ft)
30 (98.5ft)
5 (16ft)
8(26ft)
10(33ft)
10 (33ft)
8(26ft)
10(33ft)
15 (49ft)
Rough
Warped

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfca35va-nMfca50va-nMfca70va-n

Table of Contents