Summary of Contents for Sculpt SEGUIN Multivision 8000 Series
Page 1
*Download the latest manual version on our website* Edition: 08/11/2022 SEGUIN Europa 7 | Europa 7 VL | Multivision 8000 Series Visio 8 Plus | Super 9 INSTALLATION & USER GUIDE 1. SPECIFICATIONS 2. PRELIMINARY INSTALL GUIDE 3. COMPONENTS LIST 4.0 INBUILT AGAINST COMBUSTIBLE WALL 4.1 MASONRY BRICK INSTALLATION 4.2 HEBEL INSTALLATION...
Page 3
Follow @sculpt replacecollection on Instagram, Sculpt Fireplace Collection on Facebook and be sure to post your latest masterpiece installed with the hashtag #sculpt res. We hope we’ve helped make you the envy of your friends this winter and for years to come.
Page 4
This installation manual at times is updated, to view the latest manual please refer to the support section of the Sculpt Fireplace Collection website. ALL FIREPLACES IN THIS MANUAL CONFORM TO AUSTRALIAN AND NEW ZEALAND STANDARDS AS/NZS 2918:2018 DOMESTIC SOLID FUEL BURNING APPLIANCES & AS/NZS 4012/4013 2014 .
1. SPECIFICATIONS SEGUIN EUROPA 7 100% Pure cast iron, 8-12mm thickness MATERIAL 17.9kW (Average Peak) KW OUTPUT Up to 150-250m HEATING CAPACITY Clean frame-less design (trim options available) FACADE Secure swing or lift up door opening system GLASS DOOR 4.5m MINIMUM FLUE HEIGHT 200mm, 250mm, 300mm FLUE SIZES...
Page 6
SEGUIN EUROPA 7 VL 100% Pure cast iron, 8-12mm thickness MATERIAL 17.9kW (Average Peak) KW OUTPUT Up to 150-200m HEATING CAPACITY Clean frame-less design (trim options available) FACADE Secure swing or lift up door opening system GLASS DOOR 4.5m MINIMUM FLUE HEIGHT 200mm, 250mm, 300mm FLUE SIZES Recommended for well insulated homes...
Page 7
1. SPECIFICATIONS SEGUIN VISIO 8 100% Pure cast iron, 8-12mm thickness MATERIAL 27.8kW (Maximum Heat Output) KW OUTPUT Up to 240-340m HEATING CAPACITY Clean frame-less design (trim options available) FACADE Secure swing or lift up door opening system GLASS DOOR 4.5m MINIMUM FLUE HEIGHT 200mm, 250mm, 300mm...
Page 8
1. SPECIFICATIONS SEGUIN SUPER 9 100% Pure cast iron, 8-12mm thickness MATERIAL 26kW (Maximum Heat Output) KW OUTPUT Up to 200-300m HEATING CAPACITY Clean frame-less design (trim options available) FACADE Secure swing or lift up door opening system GLASS DOOR 4.5m MINIMUM FLUE HEIGHT 250mm, 300mm, 350mm...
Page 9
SEGUIN MULTIVISION 8000 SERIES 100% Pure cast iron, 8-12mm thickness MATERIAL 25.9kW* Single Sided Model (Maximum Heat Output) KW OUTPUT Up to 150-200m HEATING CAPACITY Clean frame-less design (trim options available) FACADE Secure swing or lift up door opening system (one side only) GLASS DOOR 4.5m...
Ensure you check the glass, the door(s), the damper operation and the door locking mechanism. For all warranty claims please consult your Sculpt Fireplace Collection retailer (see page 47 of manual). Before any work is carried out, as per local and national regulations and laws, this appliance MUST be...
Page 11
It is strongly recommended that the licensed trade professional who is performing the installation of this appliance, completely read and comprehend all instructions in this manual prior to proceeding. Sculpt Fireplaces & Seguin Duteriez reserves the right to change these speci cations without prior notice.
Page 12
Sculpt Fireplaces & Seguin reserves the right to change these speci cations without prior notice. IMPORTANT: For possibly replacing the ue or for a technical intervention, the installation of an access hatch on the replace cavity is highly recommended.
Page 13
2. PRELIMINARY INSTALL GUIDE PLEASE READ PRIOR TO INSTALL FRESH AIR INLET, RECOMMENDED FOR ALL INSTALLATIONS The air inlet is recommended for installation and is essential for the proper function of the appliance. The fresh combustion air inlet must be a minimum 600cm louvered air vents facing down in non-combustible material and ideally positioned (see point A &...
(4 Zero Type: aluminium inner core, aluminium outer, poly insulated, minimum RI.0) by the retailer. All Sculpt Fireplaces are tested using FloMet vented ue kits. 4.5M INBUILT TRIPLE SKIN FLUE KIT SEGUIN EUROPA 7 & VISIO 8 SG FLKIT200STD...
Page 15
3. COMPONENTS LIST Sculpt Fireplace Collection bears no liability to the functioning and supply of these components. Additional components required for installation are the responsibility of the retailer and (or) installer. 4.5M INBUILT CHIMNEY FLUE KIT SEGUIN SUPER 9 SG FLKIT250STD...
Page 16
MASONRY BRICK INSTALLATION STEP 1: BASE Lay a masonry base, minimum 150mm thick (ie. Solid bricks). The base should be laid on an adequate ground capable of supporting its weight. **IMPORTANT** If using the optional Outdoor Air Kit please leave a 125mm air gap behind the rebox.
Page 17
MASONRY BRICK INSTALLATION STEP 4: POSITIONING OF THE UNIT Place the rebox into position on top of the sheet metal. Remember to leave a 50mm air gap on all sides of the rebox. (If an outdoor air-kit is to be connected please leave a 125mm air-gap at the rear of the rebox).
Page 18
MASONRY BRICK INSTALLATION STEP 7: LAYLA 3 TRIM WITH LIFT DOOR (IF NOT REQUIRED GO TO STEP 8) **IMPORTANT** Trim must be tted onto the rebox PRIOR to installing the front of the masonry enclosure. Put the trim on the front of the rebox On the side of the façade of the rebox drill two holes at 4.2mm The holes must match with the slotted holes on the trim...
Page 19
MASONRY BRICK INSTALLATION STEP 10: CAVITY LID **IMPORTANT** SIDE VENTS It is highly recommended the cavity lid be installed at to 500mm ensure su cient air ow around the appliance if 2 vents are BELOW used. CEILING FRONT VENTS It is highly recommended the cavity lid be installed on an angle of 15°...
Page 20
MASONRY BRICK INSTALLATION STEP 13: FLUE INSTALLATION The triple skin ue will then be continued into the roof cavity and above the roof line, as per Australian & New Zealand Standard AS/NZ 2918:2018. There must be a 25mm clearance around the outer triple skin ue. The ue must extend a minimum 1m above the roof line and have a 3m diameter clearance from the top of the cowl to any objects in a horizontal direction.
Page 21
MASONRY BRICK INSTALLATION STEP 16: BAFFLE PLATE Ensuring the wider end of the ba e plate is facing the inside back wall of the rebox, and the at surfaces are positioned downwards, proceed to gently position the plate on the lugs located on the inside ceiling of the rebox.
Page 22
HEBEL INSTALLATION LIGHT WEIGHT INSTALLATION STEP 1: BASE Lay a masonry base, minimum 150mm thick (ie. solid bricks). The base should be laid on an adequate ground capable of supporting its weight, without cracking or movement. **IMPORTANT** If using the optional Outdoor Air Kit please leave a 125mm air gap behind the rebox.
Page 23
HEBEL INSTALLATION STEP 4: POSITIONING OF THE UNIT Place the rebox into position on top of the sheet metal. Remember to leave a 100mm air gap on all sides of the rebox. (If an outdoor air-kit is to be connected please leave a 125mm air-gap at the rear of the rebox).
Page 24
HEBEL INSTALLATION STEP 7: LAYLA 3 TRIM WITH LIFT DOOR (IF NOT REQUIRED GO TO STEP 8) **IMPORTANT** Trim must be tted onto the rebox PRIOR to installing the front of the masonry enclosure. Put the trim on the front of the rebox On the side of the façade of the rebox drill two holes at 4.2mm The holes must match with the slotted holes on the trim...
Page 25
HEBEL INSTALLATION STEP 11: FLUE INSTALLATION Triple skin ue is to then be continued on top of the cavity lid. The lower end of the middle skin casing shall be close tting against the lid and the outer casing must be ventilated. Air vents on the rst length of triple skin ue must be cut (please use diagram as a guide).
Page 26
HEBEL INSTALLATION STEP 14: HEARTH (FLOOR PROTECTOR) The hearth must be constructed from masonry or a non combustible material, and must extend 500mm or 600mmin front of the appliance, 300mm on either side of the appliance and a thickness of 100mm. STEP 15: BAFFLE PLATE Ensuring the wider end of the ba e plate is facing the inside back wall of the rebox, and the at surfaces are positioned...
Page 27
INBUILT INTO ISLAND WALL NON COMBUSTIBLE SURROUNDING STEP 1: BASE Lay a masonry base, minimum 150mm thick (ie. Solid bricks). The base should be laid on an adequate ground capable of supporting its weight. STEP 2: SHEET METAL LAYER (OPTIONAL STEP) Place a piece of sheet metal on top of the masonry base, this will level the base and enable you to safely manoeuvre the rebox.
Page 28
INBUILT INTO ISLAND WALL STEP 4: FIRST LENGTH OF FLUE Place the rst single skin length of ue (with no crimp) around the outside of the spigot. You may also use Fire Cement to seal the joins. Before installing the remaining lengths of ue please go to the next step.
Page 29
INBUILT INTO ISLAND WALL STEP 6: LIFT UP DOOR ASSEMBLY (IF NOT REQUIRED GO TO STEP 9) **IMPORTANT** Refer to images page 37. LIFT UP DOOR ASSEMBLY. Three bolts mount the lift up door mechanism. It is recommended that you use two solid pieces of timber approximately 450mm long in order to assist in the assembly of the door.
Page 30
INBUILT INTO ISLAND WALL STEP 8: CAVITY LID 500mm BELOW **IMPORTANT** CEILING SIDE VENTS It is highly recommended the cavity lid be installed at to 15° ensure su cient air ow around the appliance if 2 vents are used. FRONT VENTS It is highly recommended the cavity lid be installed on an angle of 15°...
Page 31
INBUILT INTO ISLAND WALL STEP 11: DUCTING (OPTIONAL) The duct MUST be 4 Zero type (aluminium inner core, aluminium outer, poly insulated, minimum RI.0) and tested to AS 4254.1-2012. Outlet MUST be metal. Cut a hole in the lid of the enclosure nearest to the room where the heat is to be transferred.
Page 32
INBUILT INTO ISLAND WALL STEP 13: HEARTH (FLOOR PROTECTOR) The hearth must be constructed from masonry or a non combustible material, and must extend 500mm or 600mm in front of the appliance, 300mm on either side of the appliance and a thickness of 100mm. STEP 14: BAFFLE PLATE Ensuring the wider end of the ba e plate is facing the inside back wall of the rebox, and the at surfaces are positioned...
Page 33
EXISTING BRICK CHIMNEY INSTALLATION EXISTING BRICK CHIMNEY INSTALLATION PLEASE READ ALL INSTRUCTIONS BEFORE COMMENCING INSTALLATION Install unit into cavity with a su cient amount of air ow on the back and sides (recommended 25mm air gap) of the appliance. Single skin ue must run from the spigot of the unit through to the top of the chimney, alternatively a funnel system can be custom made by a quali ed trades person to the speci cations of the existing brick chimney, the manufacturer and distributor bears no liability to the performance of the appliance once the custom panel has been tted to the rebox.
EXISTING BRICK CHIMNEY INSTALLATION VENTILATION OPTIONS Ventilation is required on the enclosure to help with air circulation. OPTION 1: INSTALL UNIT FREE STANDING Recommended 100mm clearance on the sides and back of the rebox OPTION 2: INBUILT WITH VENTS ON THE BOTTOM AND TOP OF THE FIREBOX Custom made vent facade can be made with a minimum metal vent size of 100mm x 600mm on the top of the rebox and...
FREE STANDING STEP 1: HEARTH (FLOOR PROTECTOR) Where combustible ooring is concerned, lay a masonry base. This can be made from tiles, granite, slate, concrete, hebel blocks, etc. The base must be a minimum 150mm thick and must protrude 500mm on all sides of the rebox. STEP 2: CLEARANCES **IMPORTANT** The unit must maintain a 1200mm clearance horizontally in...
Page 36
FREE STANDING STEP 5: INSTALLING FREE STANDING FLUE SYSTEM The rst length of black double skin ue does not have a crimped end on either side of the ue piece. Place this rst length on the outside of the rebox spigot , ensure the inner lugs are facing down closest to the rebox so that the second skin cannot move down and impede on the damper system.
Page 37
LIFT UP DOOR ASSEMBLY LIFT UP DOOR ASSEMBLY Three bolts mount the lift up door mechanism. It is recommended that you use two solid pieces of timber approximately 450mm long in order to support the counterweight in the frame, this will assist in the assembly of the door.
OPERATION & MAINTENANCE OPERATION & MAINTENANCE OPERATION & MAINTENANCE OPERATION & USER GUIDE OPERATING THE WOOD BURNER WITH THE DOOR OPEN EXPOSES YOU TO MULTIPLE HAZARDS FALLING EMBERS, SMOKE EMISSIONS IN THE ROOM, ETC. . ALWAYS OPERATE THE APPLIANCE WITH THE DOOR CLOSED. PRECAUTIONS FOR THE FIRST IGNITION - CURE WITH 10 SMALL FIRES The rst ten res should be light, moderate and not overly loaded with wood.
Page 39
OPERATION & MAINTENANCE OPERATION & MAINTENANCE OPERATION & MAINTENANCE OPERATION & USER GUIDE CONTINUED IGNITION INSTRUCTIONS (continued) After an extended time of non-use, it is recommended that the rebox be checked and cleaned by a professional to ensure there is no obstruction in the ue and no blocking of the manoeuvring members (damper) before ignition.
Page 40
For safety reasons, assemblies of appliances and accessories not provided or recommended by Seguin or Sculpt Fireplaces are NOT PERMITTED. Unsuitable equipment may cause dysfunctions and disorder upon use. EXTINGUISHING THE FIRE Stop fuelling the re and let it burn out.
Page 41
OPERATION & MAINTENANCE OPERATION & USER GUIDE CONTINUED IMPORTANT WARNING Storing any ammable materials (paper, linen, furniture, solvents, ammable liquids, spray containers, gas bottle, etc.) close to the replace is strictly forbidden. All these products should never be stored even for a short while in wood storages or recesses laid out under or near the appliance.
Page 42
OPERATION & MAINTENANCE MAINTENANCE CONTINUED FLUE & FIREBOX Flues should be professionally cleaned and checked twice a year, including at least once during the peak period of use and more if required. A professional should also check seals, door ropes, ba e plates and all consumable parts of the rebox and ue to ensure the unit is in safe working order.
Page 43
OPERATION & MAINTENANCE MAINTENANCE CONTINUED DO NOT REMOVE THE BAFFLE EXCEPT WHEN PERFORMING A CHIMNEY SWEEP CAUTION: Cracked and/or broken components (eg. glass panels or ba es) may render the installation/ operation unsafe. Do not use the appliance if this is the case and contact your dealer. ASH PAN The ash pan should be emptied regularly in order to avoid any over ow and clogging of the re grate.
Page 44
Buy new spares from the dealer in use (grate, ba e board, need to be replaced (not covered by (dealers information can be found on the rear panel, side panels, warranty - see warranty terms and website: https://sculpt replaces.com.au/ glass plate, seals) conditions) stockists/)
TEST RESULTS EUROPA 7 PARTICULATE EMISSIONS, POWER OUTPUT AND EFFICIENCY TEST TESTING LABORATORY HRL Technology MANUFACTURER Seguin Duteriez MODEL Europa 7 Evolution ISSUE DATE 01/02/2021 INVESTIGATING OFFICER Steve Marland TEST REPORT HCMG/15/098 RESULTS The appliance particulate emissions factor was 1.2/kg of hard wood that complies to AS/NZS 4014.1 and the average e ciency of the appliance for all burn rates was 60%.
Page 46
TEST RESULTS EUROPA 7 PARTICULATE EMISSIONS, POWER OUTPUT AND EFFICIENCY TEST TESTING LABORATORY HRL Technology MANUFACTURER Seguin Duteriez MODEL Europa 7 Evolution ISSUE DATE 14.12.2015 INVESTIGATING OFFICER Steve Marland TEST REPORT HCMG/15/098 RESULTS The appliance particulate emissions factor was 1.2/kg of hard wood that complies to AS/NZS 4014.1 and the average e ciency of the appliance for all burn rates was 60%.
TEST RESULTS TEST REPORTS VISIO 8 APPLIANCE POWER OUTPUT TEST TESTING LABORATORY HRL Technology MANUFACTURER Seguin Duteriez MODEL Visio 8 Plus ISSUE DATE 09.12.2015 INVESTIGATING OFFICER Steve Marland RESULTS Testing of the maximum power(kW) output of the Visio 8 insert solid fuel appliance was performed at the high burn rate prescribed in ASNZS4013 (2014) on the 24th of November 2015.
Page 48
TEST RESULTS TEST REPORTS VISIO 8 APPLIANCE POWER OUTPUT TEST TESTING LABORATORY HRL Technology MANUFACTURER Seguin Duteriez MODEL Visio 8 Plus ISSUE DATE 09.12.2015 INVESTIGATING OFFICER Steve Marland RESULTS Testing of the maximum power(kW) output of the Visio 8 insert solid fuel appliance was performed at the high burn rate prescribed in ASNZS4013 (2014) on the 24th of November 2015.
The guarantee is strictly limited to the exchange or repair by Sculpt Fireplace Collection of parts agreed to be defective, without exception. Costs of dismantling, installation, assembly and transport will under no circumstance be covered by this warranty by the manufacturer, retailer or distributor, and should be handled between the user and installer.
DATE OF PURCHASE PLACE OF PURCHASE DATE OF INSTALLATION COMPLIANCE CERTIFICATE NO. MODEL NO. NAME AND ADDRESS OF PURCHASER PHONE NO. EMAIL ADDRESS Please include a copy of your receipt and compliance certi cate EMAIL PRODUCT REGISTRATION INFORMATION TO info@sculpt replaces.com.au...
11. FINAL WORDS Whilst every e ort is taken to avoid errors, SCULPT FIREPLACE COLLECTION cannot accept responsibility for the accuracy of any statement, extract or information contained within this manual nor can any of its contributors who have submitted material for inclusion. SCULPT FIREPLACE COLLECTION may change or update this manual and anything described within it without notice.
Page 52
Sculpt Fireplace Collection is proud to be the sole importer of Seguin, Axis and Bordelet replaces, with exclusive distribution rights throughout Australia and New Zealand.
Need help?
Do you have a question about the SEGUIN Multivision 8000 Series and is the answer not in the manual?
Questions and answers