VEVOR EM2425 Instruction Sheet
VEVOR EM2425 Instruction Sheet

VEVOR EM2425 Instruction Sheet

Cable locator

Advertisement

Quick Links

Technical Support and E-Warranty Certificate
www.vevor.com/support
Cable Locator
INSTRUCTION SHEET
MODEL: EM2425
We continue to be committed to provide you tools with competitive price.
"Save Half", "Half Price" or any other similar expressions used by us only represents an
estimate of savings you might benefit from buying certain tools with us compared to the major
top brands and does not necessarily mean to cover all categories of tools offered by us. You
are kindly reminded to verify carefully when you are placing an order with us if you are
actually saving half in comparison with the top major brands.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EM2425 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for VEVOR EM2425

  • Page 1 Cable Locator INSTRUCTION SHEET MODEL: EM2425 We continue to be committed to provide you tools with competitive price. "Save Half", "Half Price" or any other similar expressions used by us only represents an estimate of savings you might benefit from buying certain tools with us compared to the major top brands and does not necessarily mean to cover all categories of tools offered by us.
  • Page 2 This is the original instruction, please read all manual instructions carefully before operating. VEVOR reserves a clear interpretation of our user manual. The appearance of the product shall be subject to the product you received. Please forgive us that we won't inform you again if there are any technology or software updates on our product.
  • Page 3 Warning-To reduce the risk of injury, user must read instructions manual carefully. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)This device may not cause harmful interference, and (2)this device must accept any interference received, including interference that may cause undesired operation.
  • Page 4 WARNING To avoid and prevent electric shock, burn or personal injury, please read this manual carefully. To avoid electric shock, do not touch any naked conductor with hand or skin; and do not ground yourself while using the instrument. Keep this instrument dry. Do not use this instrument in rain. Do not use the instrument if it is damaged or operates abnormally.
  • Page 5 PRODUCTINSTRUCTION Transmitter Figure 1 1. USB Charging Port Used to charge the transmitter's built-in lithium battery with a standard 5V USB Type-C charger. 2. Continuity Test Indicator When this red indicator lights up, it indicates that the transmitter is in continuity test mode. 3.
  • Page 6 4. Transmit Signal Strength Indicator/Impedance Indicator In digital/analog wire tracking mode, it indicates the current transmit signal strength; the more lit LEDs, the stronger the signal. In continuity test mode, it indicates the impedance of the tested conductor; the more lit LEDs, the less the impedance. 5.
  • Page 7 10. Red Alligator Clip Used to connect to the wire to be traced. 11. Black Alligator Clip Used to connect to the earth or ground. It can be connected to the grounding nail accessory. Receiver Figure 2 1. Illumination Lamp 2.
  • Page 8 3. Power knob/Sensitivity Knob Turn the knob upwards to activate the receiver's power and increase its sensitivity When the receiver is on, turn the knob downwards to decrease the sensitivity and eventually turn off the receiver. 4. Mode Indicator The mode indicator is a dual-color LED, blue indicates digital wire tracking mode and green indicates analog wire tracking mode.
  • Page 9 OPERATION INSTRUCTION Tracking Wires Warning 1. Only trace non-energized wires. 2. Don't touch any live conductor with hand or skin to avoid electric shock. 3. Always disconnect power to the circuit to be traced before using the Wire Tracker. This instrument offers two modes for wire tracking: digital wire tracking mode and analog wire tracking mode.
  • Page 10 Red Clip Black Clip Figure 3 2. Turn on the transmitter, and then pull the function toggle switch to the "DIGITAL" or "ANALOG" position for the digital or analog transmission function. The corresponding indicator will light up as an indication, and the transmitter starts to work. 3.
  • Page 11: Continuity Test

    audible and visual signals. This verifies that both the receiver and the transmitter are functioning correctly 7. Slowly move the receiver's probe from the transmitter towards the the audible and far end of the wire to be traced. By comparing visual signals emitted by the receiver, the wire with the largest sound, brightest received signal strength indicator and most lit...
  • Page 12 to the "CONT" position for the continuity test function. The continuity test indicator will light up. 2. As shown in Figure 4, connect the red and black alligator clips of the transmitter to the two ends of the line to be tested. 3.
  • Page 13: High Voltage Protection

    ATTENTION 1.Test Blind Area If the buried depth of the tested wire is greater than the distance between adjacent wires, the adjacent wire may be used as the buried wire to be tested. There is a test blind area in this wire tracker, as shown in figure 5: Wall Ground...
  • Page 14: Specification

    3.Signal Blocking Shoes with poor insulation performance will cause the human body to connect to the ground, which results in the blocking of some signals. Please make sure to wear shoes with good insulation performance during detection. SPECIFICATION Detection Depth: Analog mode: 0 to 0.3m Digital mode: 0 to 2.0m Traced Wire Length: Analog mode: 0 to 300m Digital mode: 0 to 2000m...
  • Page 15: Battery Charging/Replacement

    Operating Altitude: 0 to 2000 meters IP Degree: IP20 Size: Transmitter: 120 mm x 73mm x 28mm ( for main body only ) Receiver: 200mm x 40mm x 30mm ( for main body only ) Weight: Transmitter: About 151g ( including battery ) Receiver: About 210g ( including battery ) BATTERY CHARGING/REPLACEMENT Charging the Battery in the Transmitter...
  • Page 16 Replacing the Battery in the Receiver When the mode indicator on the receiver flashes, the battery in the receiver is not high enough and you must replace it immediately; otherwise the receiver will not operate normally or the detection result may be wrong.
  • Page 17: General Maintenance

    MAINTENANCE Warning The instrument is not waterproof. Do not let water or any liquid enter the case. Before cleaning the instrument, turn off the instrument and disconnect the instrument from any wire/ cable . Cleaning Periodically wipe the case with a damp cloth. Do not use abrasives or solvents.
  • Page 18 ACCESSORY 1. Ground rod :1 piece 2. Headset: 1 piece 3. Carrying bag: 1 piece 4. USB charing line: 1 piece 5. Manual : 1piece 6. 9V 6F22 battery: 1 piece 7. 3.7V lithium battery:1 piece 8. Phillips screwdriver: 1piece NOTE 1.
  • Page 19 DISPOSAL OF THIS ARTICLE Dear Customer, If you at some point intend to dispose of this article, then please keep in mind that many of its components consist of valuable materials, which can be recycled. Please do not discharge it in the garbage bin, but check with your local council for recycling facilities in your area.
  • Page 20 Technical Support and E-Warranty Certificate www.vevor.com/support...