Download Print this page

ADTRAN STS-1 MUX Quick Start Manual page 2

Advertisement

P
ROVISIONING
All provisioning of the MX2820 STS-1 MUX will be handled through the SCU. The menu tree below provides the options and default
settings for the MX2820 STS-1 MUX.
1. Configuration
To/from SCU menus
2. Provisioning
3. Status
4. Test
5. Performance
Note: An asterisk (*) indicates default setting
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can be
found online at www.adtran.com/warranty.
©2011 ADTRAN, Inc. All Rights Reserved.
CLEI Code
Part Number
Serial Number
Code Version
Code Checksum
Boot Version
Boot Checksum
Self Test
1. Network Interface
2. VT/Port Interfaces
3. Service States
4. Protection
5. Save Provisioning
6. Restore
Factory Defaults
7. Card Reset
8. Auto Save
9. Loopback Timeout
10. Card Pair ID
1. Detailed VT/Port
Status
1-28. VT/Port Loopbacks (T1/E1)
29. STS-1 Loopbacks
30. Reset ALL Tests
1. STS-1 Statistics
Monitoring
2. VT/Port Statistics
3. Clear All Statistics
1. Loop
2. Free-Run
1. Network Timing
3. External
1. VT1.5 (T1)
2. VT Mode
2. VT2 (E1)
3. STS-1 J1 Path Trace
1-28. T1/E1
1. T1/E1 State
29. Set Multiple
30. Auto Enable Delay
2. T1/E1 Line Coding
1-28. T1/E1
3. T1/E1 Line Length
1-28. T1/E1
4. T1/E1 Loopback Detection
1-28. T1/E1
Protection
Threshold (1-28): 1*
5. T1/E1 Circuit Protection
1-28. T1/E1
6. T1/E1 Line Identification
1-28. T1/E1
7. VT Identification
(VT #1-28)
8. T1/E1 XCV Threshold
1-28. T1/E1
1. Disabled*
9. VT Hairpin Loopback
2. Enabled
10. Cross-Connect
Mapping
1. Disabled
11. VT AIS Transmission
2. Enabled (GR-253)*
1. D Card nA
2. D Card nB
3. VT Path Service States
1-28.
4. Facility Service States
29. STS-1
30. Set Multiple
1. Perform Manual
Switch
2. Minimum Switching
Period (sec.) (10*)
3. Maximum Switch
Threshold (3*)
4. Clear Number of
Switches
1. Disabled
2. Enabled*
T1:
1. Disabled
1. Data Mode*
2. 1 Minute
2. Tributary
3. 5 Minutes*
3. Analog Network
4. 10 Minutes
4. Digital Line/Net
5. 15 Mintues
5. CODEC Line/Net
6. 30 Minutes
6. CSU Loopback
7. 45 Minutes
7. CSU LB w/BERT
8. 60 Minutes
8. Line BERT
9. VT BERT
E1:
1. Data Mode*
1. Data Mode*
2. Line
2. Tributary
3. Digital
3. Analog Network
4. Digital Line/Net
5. CODEC Line/Net
6. Remote Loopback
7. Line BERT
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY
HANDLING PRECAUTIONS REQUIRED
1. Transmitted
Received
1. 2 seconds*
2. Expected
2. 1 hour
3. Set Expected Equal
to Received
3. 2 hours
1. Disabled
4. 12 hours
2. Enabled
5. 1 day
3. Auto Enable*
6. 2 days
7. 7 days
1. AMI
T1:
2. B8ZS/HBD3*
1. 0-133 ft*
2. 133-266 ft
1. Disabled*
3. 266-399 ft
2. CSU (T1 Only)
4. 399-533 ft
3. NIU (T1 Only)
5. 533-655 ft
1. Disabled
E1:
2. Enabled*
1. 0-6dB Loss
1. Disabled*
2. 1E-3
3. 1E-4
4. 1E-5
5. 1E-6
ADTRAN CUSTOMER CARE:
From within the U.S.
From outside the U.S. +1 256.963.8716
PRICING AND AVAILABILITY 1.800.827.0807
*61186005F1-22A*
1.800.726.8663

Advertisement

loading

This manual is also suitable for:

1186005