PLACE GUTENBERG - 59175 TEMPLEMARS (France)
Tel: +33(0)3 20 60 49 49 - Fax: +33(0)3 20 95 59 62
Email:
contact@sefram.eu
Web:
www.sefram.eu
Technical manual
FI 72.0576.1023E
Page 1 / 17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SPT50 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SEFRAM SPT50

  • Page 1 SPT50 Settings console PLACE GUTENBERG - 59175 TEMPLEMARS (France) Tel: +33(0)3 20 60 49 49 - Fax: +33(0)3 20 95 59 62 Email: contact@sefram.eu Web: www.sefram.eu Technical manual FI 72.0576.1023E Page 1 / 17...
  • Page 2: Table Of Contents

    - CHARACTERISTICS - USER INTERFACE It has a touch-sensitive graphic display. Start page Main page It is powered by the SPT50 as soon as the M12 connector is Fault(s) in progress page connected to the SPT50. General menu page Graphics page...
  • Page 3: User Interface

    SPT50 Settings console USER INTERFACE: Start page : 1 : Company or manufacturer logo If the user does not take any action on the screen (press) for 5 seconds, the system automatically displays the main page on the screen. Main page : 1: Average value of dust emissions measured over X minutes.
  • Page 4: Fault(S) In Progress Page

    SPT50 Settings console Fault(s) in progress page : 1: Time-stamped list of faults present. Indication of the number, time the fault occurred and designation. 2: reset the fault by pressing the icon 3: link to general menu General menu page :...
  • Page 5: Graphics Page

    SPT50 Settings console Graphics page : 1: Graph. The y-axis represents the value of the measurements (depending on the unit chosen; e.g. mg/m3). The x-axis represents time. 2: Validation / Devalidation display of the instantaneous rejection measurement curve. 3: Validation / Devalidation: display of the curve of rejection measurements averaged over 1 minute.
  • Page 6: Security Page

    SPT50 Settings console Security page : Users are classified into 3 levels: level 0, level 1 and level 2. Levels 1 and 2 are password-protected. Access to certain functions or modification of certain parameters is possible depending on the protection level of the screen.
  • Page 7: Hmi Parameters Page

    SPT50 Settings console HMI parameters page : 1: Screen brightness setting 2: Setting the calendar clock 3: Screen size calibration Necessary when the touch screen does not respond accurately 4: Link to main page 5: link to general menu page...
  • Page 8: System Information Page

    SPT50 Settings console System information page : 1: contact details of manufacturer, supplier 2: product name 3: box serial number 4: software version name, electronic board software no. / HMI software no. 5: link to main page 6: link to general menu page...
  • Page 9: Parameter Menu Page

    SPT50 Settings console Parameter menu page : 1: Access to the measurement parameters page (unit, recording frequency, etc.) 2: Access to the relay output parameters page (choice of relay output information) 3 : Access the calibration page (product calibration) 4 : Access to the dedusting peak detection page...
  • Page 10: Measurement Parameters Page

    SPT50 Settings console Measurement parameters page : 1: Choice of unit of measurement (accessible in safety level 2) : - mg/m3 - g/m3 - µg/m3 2: X: Current period over which the averaged value is calculated (accessible in security level 1) Adjustable from 1 to 30 minutes 3: Measurement recording frequency.
  • Page 11: 4-20Ma Output Parameter Page

    SPT50 Settings console 4-20mA output parameter page (if SPT50 fitted with 4-20mA option) : 1: Type of value transmitted on the 4-20mA analogue output (accessible in security level 2) Possible choices : - Value averaged over X minutes - Instantaneous value...
  • Page 12: Relay Output Parameters Page

    SPT50 Settings console Relay output parameters page: Relay 1 settings 1: Information transmitted on relay output 1 (accessible in security level 1) Multiple choices possible 2: Link to parameters menu 3: Link to Relay 2 settings page Relay 2 settings...
  • Page 13: Calibration Page

    It is essential to carry out this step simultaneously with the intervention of the approved centre in order to guarantee that the measurement conditions between those carried out by the SEFRAM product and those carried out by the centre are identical.
  • Page 14: Dedusting Peak Detection Page

    SPT50 Settings console Dedusting peak detection page : Detection of dedusting peaks involves looking at the instantaneous rejection value in relation to a defined threshold ("peak threshold"). 1: Validation of the dedusting peak function (accessible in level 2) 2: "Peak detected" threshold setting (accessible in level 2) If the instantaneous rejection value is above the set threshold, the system considers that the measured rejection peak is due to dedusting in progress.
  • Page 15: Thresholds Page

    2: Configuration of the number of STOP bits: 1 or 2 (accessible in level 1) 3: Parity: None, Even or Odd (accessible in level 1) 4: ID number set by SPT50 encoder wheels (1 to 99). See SPT50 manual 5: Link to parameters menu Technical manual FI 72.0576.1023E...
  • Page 16: Faults

    SPT50 Settings console FAULTS: Automatic Name Reasons Effects Actions to be taken reset ALARM: High internal Temperature measured inside the sensor - Risk of damage to the temperature > temperature alarm threshold sensor - check that the dust YES after...
  • Page 17: Precautions

    CONFORMITY : The SPT50 setting console complies with current European directives (EMC directives) to which it is subject. However, it must be used correctly in the applications for which it is intended, and must be in conjunction with or in close proximity to CE-approved products.

This manual is also suitable for:

Spt50 atex