Canon varioPRINT 600 TITAN Series Service Manual page 39

Table of Contents

Advertisement

Canon
IMPORTANT
If the machine configuration has multiple PIMs or High Capacity Stackers
attached, up to three PIMs can use one power strip or quad box that
contains separate 115 V AC power outlets for each module (on the left side
of the engine). Up to three High Capacity Stackers, can use one power
strip or quad box that contains separate 115 V AC power outlets for each
module (on the right side of the engine). The use of power strips or quad
boxes also provides a power source for service tools, such as a
technician's laptop computer or vacuum; however, it is up to the customer
to provide a separate 115 V AC power source for this purpose.
Use only dedicated and properly grounded outlets for the main unit. It is
also strongly suggested to use dedicated and properly grounded outlets for
each optional accessory. Do not use extension cords. The ground
connection serves to provide the internal electronics with a reference
voltage. Faulty or poor ground sources will cause this reference voltage to
fall into a range that no longer serves as a reliable reference voltage. The
internal logic and programming of the varioPRINT 6000 TITAN Series
machines will not perform reliably because there is an insufficient
difference between the internal operating signal voltages and the poor
ground reference signal. A qualified electrician can measure and provide
the ground source that the varioPRINT 6000 TITAN Series machines or
any computer controlled office equipment requires.
Before installation, confirm that all necessary receptacles are available.
Phase converters and step-down transformers are not supported.
varioPRINT 6000 TITAN Series Service Guide
Revision 1
varioPRINT 6000 TITAN Series Service Guide
April 2021
Page 33