OPERATION MANUAL
Orbital Shaker
SHA51-350

Advertisement

loading
Need help?

Need help?

Do you have a question about the SHA51-350 and is the answer not in the manual?

Questions and answers

Summary of Contents for LABSTAC SHA51-350

  • Page 1 OPERATION MANUAL Orbital Shaker SHA51-350...
  • Page 2 Orbital Shaker SHA51-350 PREFACE Thanks for choosing Orbital Shaker. This operation manual describes function and operation of the instrument. In order to use the instrument properly, please read this manual carefully before operating the Instrument. Opening Check Please check the instrument and appendix with the packing list when you first open the packing case.
  • Page 3 Orbital Shaker SHA51-350 The instrument should be put in the place where of low temperature, little dust, no water, no sunshine or hard light, and of good aeration, no corrosively gas or strong disturbing magnetic field, and far away from central heating, camp stove and other hot resource. Do not put the instrument in wet and dusty place.
  • Page 4: Table Of Contents

    Orbital Shaker SHA51-350 Index 1. Introduction........................05 2. Specifications........................06 3. Preparation........................04 4. Operation Guide......................09 5. Failure Analysis and Trouble Shooting................10 Appendix A:Wiring Diagram of Orbital Shaker............11 www.labstac.com...
  • Page 5: Introduction

    Orbital Shaker SHA51-350 Introduction The orbital shaker is powerful variable speed shaker which provides efficient orbital motion. It is microprocessor controlled instrument with long-life brushless motor. It can be applicable in different laboratories in microbiology, chemistry, immunology, biochemistry and molecular biology.
  • Page 6: Preparation

    Orbital Shaker SHA51-350 Preparation This chapter mainly describes the instrument’s mechanical structure, the keyboard and functions of each key, as well as preparations before power on. Please learn this chapter well before the orbital shaker is to be operated at the first time.
  • Page 7 Orbital Shaker SHA51-350 2 Keyboard and Display Panel 3 Key Function 4 Power Connection Put the instrument on a horizontal and even working table. Connect power as below figure. DC socket is on the rear part of the instrument. Voltage should be between 100V and 230V.
  • Page 8 Orbital Shaker SHA51-350 5 Platform Installation Six kinds of platforms UP-12, PP-4, P6-250, P12-100, PP-4A, PW-260 are optional for orbital shaker. Installation for UP-12, PP-4, PP-4A, PW-260 Installation for P6-250 or P12-100 www.labstac.com...
  • Page 9: Operation Guide

    Orbital Shaker SHA51-350 Operation Guide 1. Speed and Timing Setting a) All digital of LED display as the right chart when power on . The instrument enters into the initial program with beep. Press or of speed key. It displays last running speed. Refer to the right chart, it is “200”...
  • Page 10: Failure Analysis And Trouble Shooting

    Orbital Shaker SHA51-350 Failure Analysis and Trouble Shooting Failure Analysis and Processing Procedures Phenomenon Possible Causes Processing Procedure No power Check the power No signal display when Broken switch Exchange the switch power on. Others Contact with the seller Samples placed...
  • Page 11: Appendix A:wiring Diagram Of Orbital Shaker

    Orbital Shaker SHA51-350 Appendix A:Wiring Diagram of Orbital Shaker (Below diagram is just for reference. It is subject to change without prior notice.) AC100V ~ AC240V J2 DC24V Main Board Motor PORT1 www.labstac.com...
  • Page 12 Orbital Shaker SHA51-350 Email: contact@labstac.com Website: www.labstac.com www.labstac.com...