4
20 mm
Torque 8 Nm
2.5 mm
6
Periodic checks
12
X Check connection and shower hoses periodically for
the following:
– Watertightness
– Corrosion
– Mechanical damage
X Use original spare parts only.
X Replace damp or dripping hoses.
X Replace hoses with rusty or oxidized surfaces.
X Replace hoses that show signs of mechanical damage.
Replacement of the flexibles
X Don't use a wrench or other items to mount the flexibles on
the tap side.
X Mount these only by hand.
X Flush all pipes thoroughly before installation.
Operating data
Operating pressure (ideal)
Operating pressure (max.)*
Operating pressure (min.)*
Water temperature (ideal)
Water temperature (max.)
* Equal pressure is recommended.
7
Cl
franke.com
EN
Value
3 bar
45 PSI
300 kPa
5 bar
70 PSI
500 kPa
1 bar
14.5 PSI
100 kPa
60°C
140°F
70°C
158°F