Use the following technique to repair the defective copper pattern at connections other than IC
Pins. This technique involves the installation of a jumper wire on the component side of the
circuit board.
Remove the defective copper pattern with a sharp knife.
Remove at least 1/4 inch of copper, to insure that a hazardous condition will not exist if the
jumper wire opens.
Trace along the copper pattern from both sides of the pattern break and locate the nearest
component that is directly connected to the affected copper pattern.
Connect insulated 20-gauge jumper wire from the lead of the nearest component on one side of
the pattern break to the lead of the nearest component on the other side.
Carefully crimp and solder the connections.
CAUTION: Be sure the insulated jumper wire is dressed so that it does not touch components or
sharp edges.
WARNING:To reduce the risk of electric shick don't remove cover or back.
No user-serviceable parts inside refer service to qualified service personnel.
Safety of operators has been taken into consideration at the design and manufacture phase, but
inappropriate operation may cause electric shock or fire. To prevent the productfrom being damaged, the
following rules should be observed for the installation, use and maintenance of th product. Read the following
safety instruction before starting the operation.
The User Manual uses the following symbols to ensure a safe operation and preventany damage to operators
or properties:
WARNING
RISKELECTRIC SHOCK
DONOT OPEN
.
10