6. I s not allowed to discard batteries in to common trash bins, they must be discarded
t i
only
in battery recycling points. Do not incinerate.
NOTE: LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
1: Maintained (*)
A: Including test device
G: Internally illuminated
*90: 1.5 hour duration
180: 3 hours duration
(*) Maintained operation: The luminaire lights its illumination source, when it is powered by the mains
power supply or not.
Non Maintained operation: The luminaire lights its illumination source, only in power supply's failure.
Note!! The installer should fill in, on the specification label, the letter G if the luminaire is used as a safety
sign.
NOTE!! After finishing the installation you must power the luminaire at least for 24 hours for
battery charging to perform the nominal autonomy.
Battery replacement
It can be done only by a competent person and after the mains interruption.
1. Follow the step 1 of the installation insrtuctions and remove the diffusor.
2. Remove the reflector (step 1 of the installation instructions).
3. Remove the old battery and place a new on of the same type and characteristics.
4. Replace the removed parts (previous steps 1, 2).
The light source contained in this luminaire shall only be replaced by the manufacturer, or his
agent, or a similar qualified person.
NOTE! The light source is non-user replaceable.
Page 2 from 4
X 1
A G
1
8
0
923193604_09_001
INSTALLATION INSTRUCTIONS FOR WALL OR CEILING MOUNTING
1. Unclip the plastic latches with a flat blade screwdriver, unfasten the 2 screws (not all the way,
step 8 B) and remove the diffusor. Place simultaneously 2 flat blade screwdrivers to the
recesses and pull up gently the reflector.
2. Install the base plastic (with the included mounting screws and plugs). WARNING!! To
preserve the ΙΡ65 rating, fit the screws with the metallic washers and plastic rings which
are included.
3. Always use in any case round mains cable, with external diameter of 5-10mm (H05RN-F
type 2x1mm² or any other type, at least equal to it's mechanical and electrical
properties). ATTENTION!! The cable must not be deformed in any way (This
requirement is important to ensure the ΙΡ65 rating). Install the gasket and make a hole in
the center by using a small screwdriver. Pass the round cable through the gasket. Install the
second included gasket in to the unused hole.
4. Place the battery's connector to the corresponding connector on the PCB.
5. Connect the mains cables to the respective terminal block Ν for neutral, L for live wire.
6. Install the included tie to fasten securely the power cables.
7. Refit the reflector (mind the holes of the indications).
8. Finally place the diffusor (mind the holes of the indications). Attention!! First the plastic
latches (A) must be secured (click sound) and then fasten the 2 screws (B) (tightening
torque 1.2 Nm).
1
L
N
5
Mains connection
4
7
N O N M A I N TA I N E D / M A I N TA I N E D O P E R AT I O N
JUMPER SELECTION
You can choose the luminaire's operation. When the
jumper is installed (by default) in the middle and left pins
maintained operation is selected.
When the jumper is installed in the middle and right pins
non-maintained operation is selected.
Page 3 from 4
2
3
L
6
N
A
8
A
B
Maintained
Non Maintained
operation
operation