4. INSTALLING INDOOR UNIT
Reset the hex bolts as shown in Fig.18.
Fig. 18
Indoor unit
Apply the indoor unit to the brackets.(Fig.19)
Fig. 19
Bolt
Indoor unit
Now, securely tighten the hex bolts in both sides.
5.2.4 GAS LEAKAGE INSPECTION
After connecting the piping, check the joints for gas leakage with gas leakage detector.
HOW TO CONNECT WIRING TO THE TERMINALS
A. For solid core wiring (or F-cable)(Fig.28A)
(1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 25mm of the exposed solid wire.
(2) Using a screwdriver, remove the terminal screw(s) on the terminal board.
(3) Using pliers, bend the solid wire to form a loop suitable for the terminal screw.
(4) Shape the loop wire properly, place it on the terminal board and tighten securely with the terminal screw using a screw driver.
B. For strand wiring(Fig.28B)
(1) Cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 10mm of the exposed strand wiring.
(2) Using a screwdriver, remove the terminal screw(s)on the terminal board.
(3) Using a round terminal fastener or pliers, securely clamp a round terminal to each stripped wire end.
(4) Position the round terminal wire, and replace and tighten the terminal screw using a screw driver.
Fig. 28
26.5
2-R2.5
232
26.5
28
21
16
68
381
Hex bolt
8 to 13mm
Bracket
5. INSTALL THE DRAIN HOSE
Select whether the drain hose will be connected to the left or right
side.(Fig.5)
Insert the drain hose into the drain pan, then secure the drain hose
with a nylon fastener.(Fig.8)
Wrap the insulation (drain hose)around the drain hose connection.
(Fig.9)
Be sure to arrange the drain hose correctly so that it is leveled lower
than the drain hose connecting port of the indoor unit.(Fig.20)
Fig. 20
Arrange the drain hose
lower than this portion
When drain hose is arranged backward.Secure the drain hose with
the VT wire. (Fig. 21)
Fig. 21
CAUTION
INSTALLATION INSTRUCTIONS
Remove the hole cover.
Drain hose
OK
VT wire hole
Drain hose
NO
Piping hole