6.
TROUBLESHOOTING
ERROR MODE
+ Buzzer alarm + number '9'
+ Buzzer alarm + number '8'
+ Buzzer alarm + number '7'
+ Buzzer alarm + number '6'
+ Buzzer alarm + number '5'
+ Buzzer alarm + number '4'
+ Buzzer alarm + number '3'
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment. When
the product becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved
containers and dispose of the product and fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
BATTERY REMOVAL
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products
containing batteries (as defined within these regulations), that they are registered with Valpak's registered compliance scheme. Jack
Sealey Ltd's Batteries Producer Registration Number (BPRN) is BPRN00705.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
CAUSE
Reverse connection
Temperature too high/low
Overcurrent protection
Trying to start the vehicle more than
4 times within 10 minutes
Two clamps are short-circuited
When the external battery voltage is
higher than the jump starter voltage
Voltage of the jump starter is too low
to start the vehicle
sales@sealey.co.uk
Original Language Version
SOLUTION
Correct the connection between the clamp and
the positive and negative poles of the battery
Allow to cool. Ensure temperature of the jump
starter is between -20
c and 60
o
Stop the device and the safe mode will
disappear after 30 seconds
Stop the device and the safe mode will
disappear after 10 minutes
Ensure clamps are not touching or connected to
the same piece of metal
Disconnect the jump starter and the car battery
Recharge the jump starter as soon as possible
to prevent battery damage
www.sealey.co.uk