BWT Bewasol Installation And Operating Manual

BWT Bewasol Installation And Operating Manual

Brine pumping system

Advertisement

Quick Links

Installation and operating manual EN
Bewasol
Brine pumping system
Subject to changes!

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bewasol and is the answer not in the manual?

Questions and answers

Summary of Contents for BWT Bewasol

  • Page 1 Installation and operating manual EN Bewasol Brine pumping system Subject to changes!
  • Page 2 German edition of the manual and editions in other languages, the information in the German document should be given preference. In the event of inconsistencies, contact our customer service; see chapter “9.1 Your contact at BWT”, page 10.
  • Page 3: Table Of Contents

    Warranty ... . . 10 Your contact at BWT ..10 Product returns ... . 10 Technical data .
  • Page 4: Safety Instructions

    ● Only perform tasks that are described in this man- her specialist training, knowledge, and experience ual or if you have been trained to do so by BWT. as well as his or her knowledge of the applicable ● Perform all tasks in compliance with all applicable regulations.
  • Page 5: Symbols Used

    Symbols used How safety instructions are displayed General danger to persons, In this document safety instructions precede any systems or the environment. sequence of actions that could cause harm to per- sons or damage to property. All hazard prevention measures must be followed. Safety instructions are displayed as follows: Danger caused by the mains voltage.
  • Page 6: Product-Specific Safety Instructions

    ► Unplug device before any service and repair work. ► If the mains cable of the product becomes damaged, you must replace it with an original BWT cable. NOTE Risk of flooding! Without mains voltage there is a risk of flooding! ►...
  • Page 7: Scope Of Delivery

    Inlet and outlet hoses are not included in the scope of delivery of the system. Intended use Proper use The BEWASOL brine pumping system is only suitable for pumping brine that occurs during the backwashing of water softening systems. The volume of regeneration water...
  • Page 8: Foreseeable Misuse

    Function Foreseeable misuse ● Failure to comply with the operating conditions The brine resulting from the backwashing of water (see chapter “10 Technical data”, page 11). softening systems is collected in the collecting tank ● Failure to adhere to the maintenance intervals and, depending on the level, conveyed into the specified in this manual.
  • Page 9: Installation

    Installation Installation may only be carried out by qualified personnel (see chapter “1.3 Personnel qualifica- tions”, page 4). ►Seal the thread on the pressure port (1.1) of the pump with Teflon tape (do not use hemp). ►Mount the pressure connection (1) supplied, con- sisting of a check valve and 19 mm hose nozzle, and tighten by hand on the pressure port of the pump without tools.
  • Page 10: Maintenance

    To check the function and leak tightness, fill the Unauthorised returns of goods will not be accept- container approx. 3 to 4 times. Check the inlets and ed by BWT. Please always contact your contract outlets when the pump starts automatically. partner first.
  • Page 11: Technical Data

    Technical data Brine pumping system Type Bewasol Inlet connections Ø 8 and Ø 19 Pressure ports Ø 19 Motor capacity Rated current Operating voltage V/Hz 230 / 50 Protection class IP20 Insulation class Max. delivery capacity l/min Max. pump lift Max.
  • Page 12: Decommissioning And Disposal

    Decommissioning and disposal 11.1 Shutting down the unit The product may be shut down and dismantled only by qualified specialists. Observe all applicable safety regulations when dismantling the system. 11.2 Disposal NOTE ► The product must not be disposed of through household waste.
  • Page 13: Eu Declaration Of Conformity

    Directive at the sole responsibility of est développé, conçu et fabriqué en accord avec les instructions mentionnées ci-dessus sous l’entière responsabilité de BWT Wassertechnik GmbH, Industriestr. 7, 69198 Schriesheim, Germany (WEEE reg. no. DE 80428986) Schriesheim, November 2021 Lutz Hübner...
  • Page 16 Further information: BWT Holding GmbH BWT Wassertechnik GmbH Walter-Simmer-Strasse 4 Industriestrasse 7 5310 Mondsee, Austria 69198 Schriesheim, Germany Phone: +43 / 6232 / 5011 0 Phone: +49 / 6203 / 73 0 E-mail: office@bwt.at E-mail: bwt@bwt.de bwt.com...

Table of Contents