MODEL: SES50
SES100
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer.
b). Before servicing or cleaning unit, switch power off at service panel and lock the service discon-
necting means to prevent power from being switching on accidentally. When the service disconnect-
ing means cannot be locked, securely fasten a prominent warning device, such as a tag, to the
service panel.
c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all
applicable codes and standards, including fire-rated construction codes and standards.
d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the National Fire Protection Association
(NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities.
f). Ducted fans must always be vented to the outdoors.
g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Inter-
rupter) - protected branch circuit (ceiling installation only).
h). This unit must be grounded.
i). Not for Use in Kitchens.
j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust
air into spaces within walls or ceilings or into attics, crawl spaces, or garages.
k). The fan must not be installed in a ceiling thermally insulated to a value greater than R40.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off
power unit.
4. Please read specification label on product for further information and requirements.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit
with the dust brush attachment.
The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual
noises, replace the motor with the exact service motor. The impeller should also be replaced.
OPERATION
Use an on/off switch to operate this fan. See "CONNECT ELECTRICAL WIRING" for details.
READ AND SAVE THESE INSTRUCTIONS
Installer: Leave this manual with the homeowner.
SES80
EXHAUST FAN
Cod: 0060302958-A

Advertisement

loading
Need help?

Need help?

Do you have a question about the SES50 and is the answer not in the manual?

Questions and answers

Summary of Contents for STERLING FANS SES50

  • Page 1 EXHAUST FAN MODEL: SES50 SES80 SES100 WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
  • Page 2 PLAN THE INSTALLATION 1. Do not use in a cooking area. 2. Two ways to connect ductwork to a factory-shipped unit. INSULATION* ROOF CAP* (Place around and (with built-in over Fan Housing.) damper) POWER HOUSING CABLE* Keep duct runs short Seal gaps around Housing.
  • Page 3 ASSEMBLY INSTRUCTIONS 5. Wall installation 5a. When the product is installed on the wall, the adaptor shall be faced upward. 5b. Slide hanger bar into the channel on the housing. Hold housing in place so that Stud the housing contacts the bottom of stud. Screw housing to stud through the hole A and hole B on the same side.
  • Page 4 INSTALL GRILLE Install ceiling material to complete the ceiling construction. Then, cut around the fan housing. To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille assembly, and position the grille into the housing with the grille springs in the appropriate slots.