Download Print this page

Troubleshooting Warnings - RIDGID Dual Suction Series Operating Instructions And Parts Manual

Dual suction sump pumps

Advertisement

INSTALLATION MANUAL

TROUBLESHOOTING WARNINGS

ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY before
installing, servicing or making any adjustments.
TOUJOURS METTRE LA POMPE HORS TENSION avant de procéder à
l'installation, à l'entretien ou à des réglages.
LET PUMP COOL FOR A MINIMUM OF 2 HOURS BEFORE ATTEMPTING TO
SERVICE. Submersible pumps contain oil that become pressurized
and hot under normal operating conditions.
LAISSER REFROIDIR LA POMPE PENDANT AU MOINS 2 HEURES AVANT
D'ESSAYER DE LA RÉPARER. Les pompes submersibles contiennent
de l'huile qui devient pressurisée et chaude dans des conditions
normales de fonctionnement.
TROUBLESHOOTING
Symptoms
Possible Cause(s)
Pump will not
1. Water level too low
start or run
2. Blown fuse or tripped circuit breaker
3. Low supply voltage
4. Motor
5. Switch
6. Inlet clogged
7. Switch obstruction
Pump starts and
1. Back-flow of water from discharge
stops too often
pipe
2. Switch
3. Check valve not functioning properly
or leaking
Pump shuts off
1. Switch
and turns on
2. Switch obstruction
independently
3. Obstruction in discharge pipe
of switch (trips
thermal overload
4. Low supply voltage
protection)
6
1. Submersible pump models have permanently lubricated
bearings and require no additional lubrication.
2. Submersible pumps contain dielectric oil for cooling.
Dielectric oil can be harmful to the environment. Follow state
environmental laws when disposing of pump.
3. The pump motor is equipped with an automatic resetting
thermal protector and may restart unexpectedly. Protector
tripping is an indication of motor overloading; as a result of
operating the pump at low heads, excessively high or low
voltage, inadequate wiring, incorrect motor conditions, or at
the end of its life.
Suggested Remedies
1. Water must be at the appropriate level to activate switch
2. If blown, determine cause and then either replace with proper
sized fuse or reset breaker
3. Contact an electrician
4. Replace pump
5. Replace pump
6. Remove debris
7. Remove obstruction to verify free motion of switch
1. Install check valve
2. Replace pump
3. Remove and examine check valve for prop er in stal la tion and free
operation. Replace check valve if necessary.
1. Replace pump
2. Remove obstruction to verify free motion of switch
3. Remove obstruction in discharge piping
4. Contact an electrician.

Advertisement

loading

This manual is also suitable for:

330rsds1000rsds500rsds