LG DL 700 Series Owner's Manual page 25

Table of Contents

Advertisement

of the exhaust system is adequate for proper
operation of the appliance. This test should be
performed to alert you to any serious problems in
the exhaust system of your home.
• Your appliance features Flow Sense
innovative sensing system that automatically
detects blockages and restrictions in dryer
ductwork. Keeping ductwork clean of lint
buildup and free of restrictions allows clothes to
dry faster and reduces energy use.
NOTE
• The appliance should be cool before starting this
test. If the appliance was warmed up during
installation, run the Air Dry cycle for a few
minutes to reduce the interior temperature.
Activating the Installation Test
1
Remove the drying rack and literature, and
then close the door.
• Do not load anything in the drum for this
test, as it may affect the accuracy of the
results.
2
Press and hold the Signal and Temp. buttons
and then press the Power button.
• On models with a glass touch control panel,
press the Power button then IMMEDIATELY
press and hold the Temp. and Wrinkle
Care buttons.
• This button sequence activates the
installation test. The code
the activation is successful.
3
TM
, an
4
5
Check the Duct Condition
If the Flow Sense
exhaust system for restrictions and damage.
Repair or replace the exhaust system as needed.
NOTE
• When the appliance is first installed, this test
will display if
1N
• Do not interrupt the test cycle, as this could
Press the Start/Pause button.
• The appliance will start the test, which will
last a few minutes. The heat will be turned
on and the temperatures in the drum will be
measured.
Check the display for results.
• During the test cycle, monitor the Flow
TM
Sense
display on the control panel. If the
TM
Flow Sense
LED has not turned on when
the cycle ends, the exhaust system is
adequate. If the exhaust system is severely
restricted, the Flow Sense
on. Other problems may also be shown with
error codes. See the chart on the next page
for error code details and solutions.
TM
• The Flow Sense
exhaust system is severely restricted. Have
the system checked immediately, as
performance will be poor.
End of cycle.
• At the end of the test cycle,
The test cycle will end and the appliance will
shut off automatically after a short delay.
TM
LED is turned on, check the
should be performed to alert you to any existing
problems with the exhaust duct in your home.
However, since the test performed during
normal operation provides more accurate
information on the condition of the exhaust duct
than the installation test, the number of bars
displayed during the two tests may not be the
same.
result in inaccurate results.
INSTALLATION
25
TM
LED will turn
LED indicates that the
will display.
O

Advertisement