Download Print this page

Sealey WPD235P.V2 Manual page 2

225l/min automatic submersible dirty water pump

Advertisement

In flood situations, user is responsible for ensuring that appropriate back-up procedures, alarms etc are correctly installed in case of pump
9
failure.
In swimming pools, fish ponds, etc, ensure location is clear of people and animals, including removal of fish from pond.
9
This pump is not designed for continuous use in a fish pond or similar water feature or display.
8
DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.
8
DO NOT use the pump for any purpose other than for that which it is designed.
8
DO NOT use to pump chemicals, fuels or salt water.
8
DO NOT insert hands into the mouth of the pump as this could lead to injury.
8
DO NOT use to pump septic tanks or settling pits. DO NOT pump any liquids other than water.
8
DO NOT operate the pump out of water. The pump pick up area must be completely submerged during operation.
8
DO NOT exceed the maximum submersible depth - see specifications.
8
DO NOT operate the pump during freezing temperatures. DO NOT leave the pump in water that may freeze.
8
DO NOT use in swimming pools if people could come into contact with the water whilst pump is in use.
8
DO NOT use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids.
8
DO NOT carry the pump by its electrical cable, or outlet pipe. Use the handle only.
8
When not in use switch off pump and remove plug from power supply. Rinse pump, drain out any water and store in a frost free, safe
8
location.
WARNING! DO NOT allow uncontrolled discharge of contaminated water which would pollute the environment.
Children from age 8 years and above, persons with reduced physical, sensory or mental capabilities, those with lack of experience
and knowledge can use the appliance, if they have been given supervision or instruction concerning use of the appliance In a safe
way to understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance on the
appliance shall not be maintained by children without supervision.
2. SPECIFICATION
Manufactured from heavy-duty corrosion resistant materials with steel motor case and polypropylene base cover. Fitted with an automatic
cut-out, which can be set at multiple heights using an innovative cable fixed mounting bracket. Minimum water depth of 40mm. Designed for
operation in dense and dirty water with a maximum particle size of 30mm. Suitable for the effective drainage of cellars, sinks, cisterns, baths and
the general transfer of water and dense liquids.
3. SPECIFICATION
Model no: .........................................................WPD235P.V2
Cut-out: .................................................................. Automatic
Outlet OD: ..........................................................Ø25/Ø38mm
Maximum output/min: ........................................ 225ltr/(50gal)
Maximum head: ................................................................. 8m
Maximum water depth: ...................................................... 7m
Minimum water depth ................................................... 40mm
Maximum particle size: ................................................. 30mm
Motor power: .................................................................750W
Supply: ...........................................................................230V
4. OPERATION
4.1.
INSTALLATION AND COMMISSIONING
4.1.1.
Attach a sufficiently long and strong rope to the handle
before first use. The pump is submerged into the liquid
on this holding rope and can also be carried with it as
well as the handle.
NOTE: DO NOT suspend unit from power cable.
NOTE: With continuous use of the pump, the condition
of the rope must be regularly checked as it can decay
and break over time.
Connect pressure pipe
4.1.2.
4.1.2.1.
For occasional use, use a suitable water hose.
4.1.2.2.
The use of rigid pipes with a non return valve is
recommended for use at a fixed location. This prevents
return flow of liquid when switching off.
4.1.2.3.
Screw the pressure line onto the pressure connection.
4.1.2.4.
All threaded connections must be sealed with thread
sealing tape.
4.1.2.5.
When using a hose, screw a suitable hose adaptor onto
the pressure connection. Push the hose firmly onto the
hose adaptor and secure with a hose clamp.
Installation
4.1.3.
4.1.3.1.
The pump needs an area of at least 50 x 50cm (the float switch must be able to move freely so that it functions properly.
4.1.3.2.
The pump can be submerged under water to the submerged operating depth of 7metres.
4.1.3.3.
Install the pump so that the suction openings cannot be blocked by foreign bodies (place the appliance on a firm, even base if
necessary.
4.1.3.4.
Ensure that the pump is stable.
DO NOT lift the pump with the cable or the pressure hose as these are not designed for the tensile stress from the weight of the pump.
8
4.1.3.5.
Submerge the pump at an angle into the liquid to be delivered, so that no air pocket forms on the underside of the appliance. Suction
would be prevented by this. Once the pump is submerged, it can be righted again.
4.1.3.6.
Leave the pump at the bottom of the liquid container. Use a strong rope attached to the carrying handle of the pump for lowering.
© Jack Sealey Limited
Float Switch
Holder on
Rear Face
Float
Switch
Original Language Version
WPD235P.V2
Issue:1
01/11/22

Advertisement

loading