KIT COMPONENTS
FA01940-EN
88003-0156
EN
English
CAME S.p.A.
Via Martiri della
Libertà, 15
31030 Dosson di Casier
Treviso – Italy
Tel. (+39) 0422 4940
Fax (+39) 0422 4941
info@came.com -
www.came.com
02/2023 - FA01940-EN
1
Control board ZL371
2
Fuse 1.6A (line 230 V)
3
Fuse 3.15A (line 120 V)
4
Ferrite
5
EMC fi lter
6
Terminal block with fuse compartment

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZL371 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CAME ZL371

  • Page 1 KIT COMPONENTS Control board ZL371 FA01940-EN Fuse 1.6A (line 230 V) Fuse 3.15A (line 120 V) Ferrite EMC fi lter Terminal block with fuse compartment 88003-0156 English CAME S.p.A. Via Martiri della Libertà, 15 31030 Dosson di Casier Treviso – Italy Tel.
  • Page 2 Terminal board associated with the RSE connector for paired, alternate or CRP connection Terminal board for power supply to the control board Terminal board for connecting the antenna Accessories fuse Programming buttons Page 2 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 3 INSTALLING Page 3 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 4 Before working on the control panel, cut off the mains power supply. ① ② ③ Red cable White cable Black cable Cable provided ZL37F 120 / 230 V AC Page 4 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 5 Always insert the line fuse in the terminal block. ZL371 120 / 230 V AC Page 5 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 6 Accessories 10 - 11 24 AC Additional light 10 - E1 24 AC Flashing beacon 10 - E1 24 AC Operator status warning light 10 - 5 24 AC Page 6 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 7 Antenna with RG58 cable Control device (NO contact) PARTIAL OPENING function The contact must only be used for operators working in paired mode. 10 11 E1 E6 Rx Tx 3P 4 Page 7 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 8: Signalling Devices

    It fl ashes when the operator opens and closes. It notifi es the user of the operator status. It fl ashes when the operator opens and closes. 10 11 E1 E6 Rx Tx 3P 4 Page 8 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 9: Safety Devices

    Standard connection Connection with safety test 10 11 E1 E6 Rx Tx 3P 4 10 11 E1 E6 Rx Tx 3P 4 11 NO C NC 11 NO C NC Page 9 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 10 Connection with safety test 10 11 E1 E6 Rx Tx 3P 4 10 11 E1 E6 Rx Tx 3P 4 2 TX C NC TX 2 2 TX C NC TX 2 Page 10 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 11 Connection with safety test 10 11 E1 E6 Rx Tx 3P 4 10 11 E1 E6 Rx Tx 3P 4 10 11 OUT 10 11 SY 10 11 OUT 10 11 SY Page 11 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 12 Connection with Sleep Mode 10 11 E1 E6 Rx Tx 3P 4 10 11 OUT 10 11 SY Page 12 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 13: Getting Started

    Press the STOP button immediately in the event of any faults, malfunctions, strange noises or vibrations, or unexpected behaviour in the system. At the end of commissioning, check the correct operation of the device using the buttons near the display. Check that the accessories also work correctly. Page 13 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 14: Functions Menu

    With the function active and the operator stopped, an open or close command is not 0 =Deactivated (Default) performed if the safety devices detect an obstacle. 1 = Activated Page 14 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 15 Adjust the time for which the beacon is activated before each manoeuvre. 0 =Deactivated (Default) 1 to 10 seconds Operating time Set the gearmotor working time during opening and closing. 5 to 120 seconds (Default 120 seconds) Page 15 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 16 Adjust the obstruction detection sensitivity during slowdown in percentage terms. 10% to 100% (Default 100%) 10% = minimum thrust and high obstruction sensitivity 100 % =maximum thrust and low obstruction sensitivity Page 16 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 17 0 = when opening and closing (Default) 1 = only when closing Set how much earlier the fl ashing beacon is activated under the function [F21 2 = only when opening - Pre-fl ashing time]. Page 17 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 18 Alternatively, the control device associated with the user you want to remove can be activated. Press ENTER to confi rm. Remove all Remove all registered users. 0 =Deactivated (Default) 1 = Activated Page 18 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 19 Restore operator factory settings. 0 =Deactivated (Default) 1 = Activated Manoeuvre counter View the number of operator manoeuvres. 1 = 1000 maneuvers FW version Display the fi rmware version. Page 19 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 20: Electrical Connections

    The devices and accessories must be connected to the control board which will be set as the MASTER. Deactivate function F19 on the SLAVE operator control panel. UTP CAT 5 (max 1000 m) Page 20 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 21: Operating Modes

    Press ENTER to confi rm. Press ENTER to confi rm. For user storage operations, see function U1. Operating modes STEP-BY-STEP or OPEN ONLY command PARTIAL OPENING command (2-3P) MASTER MASTER SLAVE SLAVE Page 21 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 22: Alternate Operation

    For information on connecting the electrics for the devices and accessories, please see the “ELECTRICAL CONNECTIONS” section. The control and safety devices must be connected on both electronic boards. Deactivate function F19 on the SLAVE operator control panel. UTP CAT 5 (max 1000 m) Page 22 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 23 Press ENTER to confi rm. Press ENTER to confi rm. Select 2. Select 1. Press ENTER to confi rm. Press ENTER to confi rm. For user storage operations, see function U1. Page 23 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 24 Operating modes The MASTER barrier is marked A; the SLAVE barrier is marked B. ONLY OPEN command (2-3) on barrier A Barrier B opens automatically when barrier A closes. Page 24 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 25 PARTIAL/PEDESTRIAN OPENING command (2-3P) on barrier B Barrier A opens automatically when barrier B closes. Page 25 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 26 STEP-BY-STEP command (2-7) on barrier A or B for emergency opening Page 26 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 27: Error Messages

    The <n> value is associated with the selected parameter for the functions [F2 - CX input] [F3 - CY input]. ERROR MESSAGES Service test failure error Maximum number of detected obstructions Both limit switches are open Incompatible transmitter error Page 27 - Manual - FA01940-EN - 02/2023 © CAME S.p.A.
  • Page 28 Via Martiri della Libertà, 15 31030 Dosson di Casier Treviso – Italy Tel. (+39) 0422 4940 Fax (+39) 0422 4941 © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions...