COMMAND BOARD PLUS FOR BARRIERS WITH 230V MOTOR INSTALLATION MANUAL...
Page 2
4.1 Command board Fully designed and built by CAME CANCELLI AUTOMATICI S.p.A. Guaranteed for 24 months unless tampered with. The command board is powered at 230V A.C. on the L-N terminals with 50÷60 Hz frequency and is protected in input with 5A fuse.
Optional accessories: - fl ashing dome signals the bar in motion; - lighted cord signals the bar closed or in motion; it turns off only if the bar is at an end stop and opens. - bar open light marks the position of opening of the bar; it turns off after the closing operation. Caution: Switch off the mains prior to any inspection or maintenance work on the equipment.
5 Installation 5.1 Preliminary checks Before proceeding with the installation, it is necessary to: - provide for suitable omnipolar disconnection device with more than 3 mm between contacts to section power supply; connections inside the case made for protection circuit continuity are allowed as long as they include additional insulation with respect to other internal drive parts;...
Page 5
5.4 Installing the electrical card G2081 G4041 G2081I G4041I 1) Unscrew the four mounting screws (or three in the case of the G4041) of the cover of the container located on the upper part of the automation. 2) Insert the card into the container and fasten it with the screws supplied.
5.5 Electrical connections FC FA F 230V (a.c.) power supply 230V(a.c.) motor (Condenser) Flashing dome 24V (A.C.) max.8W, signals the bar in motion Cord signals 24V (A.C.) max. 24W, signals the bar closed or in motion, it turns off only if the bar is in open end stop mode Pilot light indicating “barrier open”...
Page 7
Output supplied for electric lock (comes on with the opening command) - VB2 (preset) supplied for electric - VB1 (shifted) supplied for lock a 24V electric lock a 12V 5.6 Photoelectric cells performance test Allows the control assembly to check the effi ciency of the safety de- vices (photoelectric cells) after each opening or closing command.
5.9 Function selections 1 ON Automatic closing function activated; (1 OFF-deactivated); 2 ON “Open” function with activated remote control (HF board inserted); 2 OFF “Open-close-reverse” function with pushbutton (2-7) and activated remote con- trol (HF board inserted) ; 3 ON “Maintained Action”...
Page 9
6 Installation procedure of the transmitter for remote control Read the three steps below before beginning installation procedures: - prepare the radio board (paragraph 6.1); - procedure for codifying the transmitter (paragraph 6.2); - memorizing the code on the command board (paragraph 6.3). 6.1 Prepare the radio board (AF) 1) On AM transmitters operating at 433.92 MHz (TOP and TAM series), position the jumper connection on...
Page 10
T262M - T302M The fi rst encoding operation must be carried out whilst keeping the jumpers po- sitioned for channels 1 and 2 as per fi g. A; see fi g. B for any subsequent settings on different channels. P1 = CH1 - P2 = CH3 P1 = CH3 - P2 = CH2 FIG.A FIG.B...
Page 11
TOP SERIES T432M - T312M set the code to dip-switch C and channel to D (P1=CH1 and P2=CH2, default setting) T434M - T314M T432S - T432SA - T434MA - T432NA - T434NA set code only see instructions on pack P1 = CH1 P2 = CH2 P3 = CH3 P4 = CH4...
Page 12
6.3 Memorizing the code on the command board Flashing LED 1) Keep the "CH1" key pressed on the base card, the signal LED will fl ash. 2) Press a transmitter key to send the code; the LED will remain lighted to signal memorization. Follow the same procedure with the “CH2”...
UNI EN ISO 14001 standard to ensure environmental protection. Please continue our efforts to protect the environment—which CAME considers one of the cardinal elements in the development of its operational and market strategies—simply by observing brief recommendations as regards disposal: DISPOSAL OF PACKAGING –...
Page 14
CAME UNITED KINGDOM LTD UNIT 3, ORCHARD BUSINESS PARK TOWN STREET, SANDIACRE NOTTINGHAM - NG10 5BP - U.K. Tel 0044 115 9210430 Fax 0044 115 9210431...