Panasonic CT-27C8G Service Manual page 3

Hide thumbs Also See for CT-27C8G:
Table of Contents

Advertisement

1
Safety precautions
General guidelines
An isolation transformer should always be used during the
servicing of a receiver whose chassis is not isolated from
AC power line. Use a transformer of adequate power rating
as this protects the technician from accidents resulting in
personal injury from electrical shocks. It will also protect the
receiver from being damaged
by accidental shorting that
may occur during servicing.
When servicing, observe the original lead dress, especially
in the high voltage circuit. Replace all damaged parts (also
parts that show signs of overheating.)
Always
replace
protective
devices,
such
as fish paper,
isolation
resistors
and
capacitors,
and
shields
after
servicing
the
receiver.
Use
only
manufacturer's
recommended
rating for fuses, circuits breakers, etc.
High potentials are present when this receiver is operating.
Operation of the receiver without the rear cover introduces
danger
for electrical
shock.
Servicing
should
not
be
performed by anyone who is not thoroughly familiar with the
necessary
precautions
when
servicing
high
voltage
equipment.
Extreme
care
should
be
practiced
when
handling
the
picture tube. Rough handling may cause it to implode due
to atmospheric pressure. (14.7 Їрв per sq. in.). Do not nick
or scratch the glass or subject it to any undue pressure.
When
handling, use safety goggles and heavy gloves for
protection. Discharge the picture tube by shorting the anode
to chassis ground (not to the cabinet or to other mounting
hardware). When discharging connect cold ground (i.e. dag
ground lead) to the anode with a well insulated wire or use
a grounding
probe.Avoid
prolonged
exposure
at close
range to unshielded areas of the picture tube to prevent
exposure to x ray radiation.
The test picture tube used for servicing the chassis at the
bench
should
incorporate
safety
glass
and
magnetic
shielding. The safety glass provide shielding for the tube
viewing area against x ray radiation as well as implosion.
The magnetic shield limits the x ray radiation around the
bell of the picture tube in addition to the restricting magnetic
effects. When
using a picture tube test jig for service,
ensure
that the jig is capable of handling 5OkV without
causing x ray radiation.
Before
returning
a serviced
receiver
to the
owner,
the
service technician must thoroughly test the unit to ensure
that is completely
safe to operate.
Do
not use a line
isolation transformer when testing.
Leakage current cold check
Unplug the A.C. cord and connect a jumper between the
two
plug
prongs.Measure
the
resistance
between
the
jumpered
AC
plug and
expose
metallic
parts such
as
screwheads,
antenna terminals, control shafts, etc. If the
exposed metallic part has a return path to the chassis, the
reading
should
be between
240kO
and
5.2МО.
ЇЇ the
exposed metallic part does not have a return path to the
chassis, the reading should be infinite.
Leakage current hot check
Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer during the check.
Connect a 1.5kQ 10 watt resistor in parallel with a 0.15uF
capacitor between an exposed metallic part and ground.
Use earth ground, for example a water pipe.
Using a DVM with a 1000 ohms/volt sensitivity or higher,
measure the AC potential across the resistor.
Repeat the procedure and measure
the voltage present
with all other exposed metallic parts.
Verify that any potential does not exceed 0.75 volt RMS. A
leakage
current
tester
(such
a
Simpson
model
229,
Sencore model PR57 or equivalent) may be used in the
above procedure, in which case any current measure must
not exceed 0.5 milliamp. If any measurement is out of the
specified limits, there is a possibility of a shock hazard and
the receiver must be repaired and rechecked
before it is
returned to the customer.
"АС VOLTMETER
TO "INSTRUMENTS ©.
V l
EXPOSED
METAL 15009,10У/
PARTS
Hot check circuit
Insulation test
Connect an insulation tester between an exposed metallic
part and A.C. line. Apply 1080VAC/60Hz
for 1 second.
Confirm that the current measurement is 0.5mA - 2.0mA.
Repeat test with other metallic exposed parts.
X ray radiation
WARNING
The potential source of x ray radiation in the TV set is in
the high voltage section and the picture tube.
NOTE
It is important
to use
an
accurate,
calibrated
high
voltage meter.
Set the brightness, picture, sharpness and color controls to
minimum.
Measure the high voltage. The high voltage should be 29.25
x 1.25kV. If the upper limit is out of tolerance, immediate
service and correction is required to insure safe operation
and
to prevent the possibility of premature
component
failure.
Horizontal oscillator disable circuit test
This test must be performed as a final check before the
receiver
is returned
to the customer.
See
horizontal
oscillator disable circuit procedure check in this manual.