1.0 INSTALLATION

1.1 Unpack and Inspect the Equipment

The following components should be included:
1   UIM-2E1
4   #6 Phillips Panhead Nylon Locking Screws
2   #6 Phillips Beige Flathead Screws
If there is any visible damage, do not attempt to connect the device. Contact Customer Support at 1-877-
638-2638 (1-603-427-0600 for international customers) or

1.2 Configure the E1 Ports

The E1 Configuration Switches for both Port 1 and Port 2 are on the component side of the UIM-2E1 circuit
board, opposite the faceplate/label. When facing the Configuration Switches, Port 1 switches are on the
left and Port 2 switches are on the right. Switches for both ports are numbered from left to right, #1-8.
N
Port 2 Configuration Switches on the UIM-2E1 are NOT USED: frame type and line code for Port 2 are determined by
OTE
the Port 1 switch settings. BOTH ports determine speed and timing configurations via communication with the remote
E1 equipment to which the UIM-2E1 is connected.
Switch # Configuration Switch # Configuration
1
not used
2
not used
3
FRAME TYPE
4
LINE CODE

1.2.1 Frame Type

Frame type is the data encapsulation method. An E1 frame consists of 248 data bits (an 8-bit
sample of each of the 31 E1 data channels), plus 8 synchronization bits, transmitted at a rate of
8,000 frames per second across the E1 line.
220-0000083 rev 01
UIM-2E1
E1 Loop Bonding Uplink Interface Module
PORT 1 SWITCHES
5
not used
6
not used
7
not used
8
not used

Installation Instructions

support@nettonet.com
.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UIM-2E1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Net to Net Technologies UIM-2E1

  • Page 1: Installation Instructions

    Port 2 switches are on the right. Switches for both ports are numbered from left to right, #1-8. Port 2 Configuration Switches on the UIM-2E1 are NOT USED: frame type and line code for Port 2 are determined by the Port 1 switch settings.
  • Page 2 1.3.1.1 Affix the UIM-2E1 to a MUM The UIM-2E1 can be installed on a MUM that is already in service, though you must remove the MUM from the IP DSLAM chassis in order to do so. Removal of a MUM from a powered IP DSLAM will not affect the operational status of other modules within the chassis;...
  • Page 3 Remove the (8) beige flathead screws securing the Mini DSLAM chasis and carefully lift off the chassis cover. Set the screws aside. Select a port on the Mini DSLAM for UIM-2E1 installation: either port (1 or 2) may be used. Although not required for operational purposes, if redundancy is desired two UIMs may be installed on a Mini DSLAM, one in each port.
  • Page 4 Plug the E1 cable into one of the two E1 RJ45 ports on the UIM-2E1 faceplate; either port (1 or 2) may be used. Verify the connection: the E1 Lnk LED on the UIM-2E1 faceplate (Port 1 Lnk or Port 2 Lnk depending upon which port was connected) will flash green to indicate the connection is established and operational.
  • Page 5: Additional Information

    (A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid, less constant rate.) 3.2 European Regulatory Compliance for Class A Equipment The following regulatory compliance information applies to the UIM-2E1 as installed in a Mini DSLAM or on a MUM in an IP DSLAM. 220-0000083 rev 01...
  • Page 6 This Class A product complies with European Norm EN55022. Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to correct the situation. 220-0000083 rev01 © Copyright 2002 Net to Net Technologies, Inc. ™...

Table of Contents