C
Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when handling
AUTION
this equipment.
1.0 INSTALLATION
1.1 Unpack and Inspect the Equipment
The following components should be included:
1 UIM-2E1
4 #6 Phillips Panhead Nylon Locking Screws
2 #6 Phillips Beige Flathead Screws
If there is any visible damage, do not attempt to connect the device. Contact Customer Support at 1-877-
638-2638 (1-603-427-0600 for international customers) or
1.2 Configure the E1 Ports
The E1 Configuration Switches for both Port 1 and Port 2 are on the component side of the UIM-2E1 circuit
board, opposite the faceplate/label. When facing the Configuration Switches, Port 1 switches are on the
left and Port 2 switches are on the right. Switches for both ports are numbered from left to right, #1-8.
N
Port 2 Configuration Switches on the UIM-2E1 are NOT USED: frame type and line code for Port 2 are determined by
OTE
the Port 1 switch settings. BOTH ports determine speed and timing configurations via communication with the remote
E1 equipment to which the UIM-2E1 is connected.
Switch # Configuration Switch # Configuration
1
not used
2
not used
3
FRAME TYPE
4
LINE CODE
1.2.1 Frame Type
Frame type is the data encapsulation method. An E1 frame consists of 248 data bits (an 8-bit
sample of each of the 31 E1 data channels), plus 8 synchronization bits, transmitted at a rate of
8,000 frames per second across the E1 line.
220-0000083 rev 01
UIM-2E1
E1 Loop Bonding Uplink Interface Module
PORT 1 SWITCHES
5
not used
6
not used
7
not used
8
not used