Download Print this page

Maytag Amana DSA02NO Installation Instructions page 2

Ptac wireless thermostat kit

Advertisement

Thermostat Installation for DSA02NO Kit
1. Select thermostat mounting location about five feet
above the floor, on an inside wall, out of direct sunlight,
away from sources of radiant heat (lamps, fireplaces,
heating and air conditioning equipment, etc.), away from
windows or door to the outside, and avoid areas with
poor air circulation.
Ensure location is out of the path of foot traffic where a
person might accidentally bump into the thermostat and
damage the device but is visible and convenient for the
room guests to locate and operate.
2. Remove thermostat from mounting plate by pulling apart
at the bottom of the thermostat about 1", and slide ther-
mostat up to release from the top of the mounting plate.
3. Place thermostat mounting plate against the wall at
desired location and mark placement of mounting holes.
Make sure the UP arrow is pointing up on the mounting
plate.
4. When mounting, drill a 3/16" hole and tap plastic anchor
into wall.
5. Screw mounting plate to the wall.
6. Install two (4) AA batteries (included) into the back of the
thermostat. Terminals are marked "+" and "-" for polarity.
7. Prior to attaching the thermostat body to the wall plate,
follow the steps on in the next section "Binding of RF
Device" of this document for binding the thermostat.
When these steps are completed and the thermostat has
been bound, continue with verifying the unit's operation.
8. Once the binding process has been completed and the
operation process has been verified, install the
DSA02NO thermostat to the wall plate by aligning the
top two tabs of the thermostat to the top two slots on the
mounting plate. Once the two tabs are aligned with the
two slots, press slightly downward so the tabs fall into
the slots. Press the bottom of the thermostat toward the
mounting plate until the bottom fasteners snap securely
into place.
NOTE: Do not install the thermostat on the wall plate until
the binding process has been completed and the operation
has been verified.
Binding of RF Device
RF TRANSMITS THROUGH WALLS.
The wireless device, DSA02NO, must be bound to the
PTAC for proper in-room communication. Ensure the
PTAC unit is powered but in the OFF position.
1. Remove the 2 screws securing the splash guard from
the control panel to access the bind button on the con-
trol board.
2. You will need to bind the thermostat to the unit. In order
to bind the thermostat you will push the red button
located on the board next to the wired thermostat plug
and hold it for at least 5 seconds and then release the
button, next press the bind button on the wireless
thermostat.