CAUTIONS AND LIMITATIONS LOCATED ON THE NIOSH APPROVAL LABEL:
A - Not for use in atmospheres containing less than 19 percent oxygen.
B - Not for use in atmospheres immediately dangerous life or health.
C - Do not exceed maximum use concentrations established by regulatory standards.
D - Airline respirators can be used only when the respirators are supplied with respirable air
meeting the requirements of CGA G-7.1 Grade D or higher quality.
E - Use only the pressure ranges and hose lengths specified in the instruction manual.
J - Failure to properly use and maintain this product could result in injury or death.
M - All approved respirators shall be selected, fitted, used and maintained in accordance with
MSHA, OSHA and other applicable regulations.
N - Never substitute, modify, add, or omit parts.
configuration as specified by the manufacturer.
O - Refer to users Instructions and/or maintenance manuals for information on use and
maintenance of these respirators.
S - Special or critical User's Instructions and/or specific use limitations apply. Refer to User's
Instructions before donning.
ALLEGRO INDUSTRIES air hose is approved for use with this Supplied Air Respirator.
Using any other hose will automatically void the approval of the respirator and may be
hazardous to the wearer.
Before occupational use of this respirator a written respiratory protection program must be implemented
meeting all the local government requirements. In the United States employers must comply with OSHA
29 CFR 1910.134 which includes medical evaluation, training, and fit testing.
Not for use in atmospheres containing less than 19.5 percent oxygen. Approved for use with respirable
air meeting the requirements of the Compressed Gas Association specifications G-7.1, for type 1, Grade
D air, through no more than three (3) lengths of approved hose as specified in the following chart.
9901 Mask
Hose
9100-XX
Length/
L.P. Hose
Ft.
0
1 – 3 PSI
25
8 – 12 PSI
50
10 – 20 PSI
75
14 – 22 PSI
100
15 – 22 PSI
150
20 – 31 PSI
200
22 – 38 PSI
250
26 – 42 PSI
300
29 – 45 PSI
S-SPECIAL OR CRITICAL USERS INSTRUCTIONS
Flow Controller/Hose Length to Pressure
9902 Mask
"EF", LP Flow
Adapter
P/N 9910-11EF
9100-XXEF
L.P. Hose
N/A
N/A
0.7 - 1.2 PSI
N/A
1.2 - 1.8 PSI
N/A
2.0 - 3.0 PSI
N/A
2.2 - 4.5 PSI
Use only exact replacement parts in the
Warning!
9902 Mask
Flow Control
Valve
P/N 9992
9101-XXB
H.P. Hose
N/A
20 – 25 PSI
20 – 25 PSI
25 – 35 PSI
25 – 35 PSI
30 – 45 PSI
30 – 45 PSI
35 – 50 PSI
35 – 50 PSI
5
9902 Mask
9902 Mask
Personal Air
Air Temp.
Cooler
Controller
P/N 9991
P/N 9990
9101-XXB
9101-XXB
H.P. Hose
H.P. Hose
N/A
50 – 70 PSI
55 – 80 PSI
50 – 70 PSI
60 – 85 PSI
55 – 75 PSI
60 – 85 PSI
55 – 75 PSI
65 – 90 PSI
60 – 80 PSI
70 – 95 PSI
60 – 80 PSI
70 – 95 PSI
65 – 85 PSI
75 – 100 PSI
65 – 85 PSI
85 – 105 PSI
N/A