Mounting Space; Operation - Leister CHINOOK Operating Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 10

Mounting space

To ensure adequate cooling of the ring compressor, the required minimum clearances to the motor fan cowl and to
the face of the compressor cover must be maintained.
Minimum distance to compressor cover
≥ 200 mm

Operation

ƒ The permissible ambient temperatures are between -20 °C and +60 °C. Good
room ventilation must be ensured.
ƒ The permissible intake temperatures are between 60 °C and +350 °C.
ƒ The blower must be connected by a technical specialist. Ensure that the
direction of rotation is correct!
ƒ The correct wiring for the mains voltage used must be configured in the
terminal box (5). Connect a protective conductor to the earthing terminal,
measure the earth resistance.
Minimum distance to motor fan cover
≥ 200 mm
50 Hz 230 V
60 Hz 265 V
W2
U2
U1
V1
L1
L2
50 Hz 400 V
60 Hz 460 V
V2
W2 U2
V2
W1
U1
V1
W1
L3
L1
L2
L3
13