Device (IAD) require a filter to isolate the voice frequency range from the SuperLine signal. Basic Configurations 4-Wire Series The SuperLine 6040 Wall Jack Filter replaces the first wall jack in a 4-wire series configuration. SuperLine 6040 Wall Jack Filter...
Page 2
4-Wire Star The SuperLine 6040 Wall Jack Filter replaces all wall jacks in a 4-wire star configuration (where each wall jack is wired individually to the NID). Filter Installation In a 4-Wire Star Configuration 3, 4 2, 5 3, 4...
Page 3
You may need to run new wiring to the location of the SuperLine IAD in a 2-wire configuration. New Wiring Added for SuperLine IAD Unfiltered Filter Installation In a 2-Wire Configuration SuperLine 6040 Wall Jack Filter 3, 4 3, 4 Standard Jack Added for SuperLine IAD...
Wire cutter Wire stripper Installation Checklist Installation of the SuperLine 6040 Wall Jack Filter consists of the following steps: Disconnect the customer premises wiring from the local loop. Determine whether wall jacks are wired in series or individually. Replace wall jacks with SuperLine 6040 Wall Jack Filters as required.
Installation 1. Disconnect the Line At the NID (Network Interface Device) or first accessible entry point, disconnect the customer premises wiring from the local loop. WARNING: Do not continue unless the line has been disconnected. Refer to Important Safety Instructions, page 13. 2.
Page 6
Replace the Wall Jack with a Filter – NID Not Accessible, or 2-Wire on page 8. Use the following procedure to install a SuperLine 6040 Wall Jack Filter when the NID is accessible. When this procedure is complete, filtering is provided on Pins 3 and 4 and SuperLine service is provided on Pins 2 and 5 of all wall jacks.
Page 7
To NID 5. Fasten the filter assembly to the wall box using the screws that held the old wall jack. An engraving on the filter assembly (UP ) shows the proper orientation. 6. Fasten the faceplate to the filter assembly. If any other wall jacks are wired individually to the NID (see Determine Wiring Arrangement on page 5), repeat the procedure for all wall jacks.
Page 8
If the configuration is not 2-wire and the NID is accessible, go to 3A. Replace the Wall Jack with a Filter – NID Accessible on page 6. Use the following procedure to install a SuperLine 6040 Wall Jack Filter when the NID is not accessible or the customer premises configuration is 2-wire. When this procedure is complete, filtering is provided on Pins 3 and 4 and SuperLine service is provided on Pins 2 and 5 of all wall jacks.
Page 9
6. Connect the wires to the screw terminals on the filter: Customer Premises Wiring (If Present) Green or White/Blue from NID Red or Blue/White from NID Green or White/Blue to next jack Red or Blue/White to next jack Black or White/Orange to next jack Yellow or Orange/White to next jack White or White/Green both from NID and to next jack...
Page 10
5. At the NID, reconnect the line to the local loop. New Wiring Added for SuperLine IAD SuperLine IAD Installation In a 2-Wire Configuration SuperLine 6040 Wall Jack Filter 3, 4 3, 4 Standard Jack Added for SuperLine IAD...
Page 11
4B. Prepare a Wall Jack for the SuperLine IAD – 4-Wire Use the following procedure to prepare a wall jack for the SuperLine IAD in a 4-wire configuration. " Procedure 1. Determine where the customer wants the SuperLine IAD installed. 2.
Page 12
4. At the NID: — Join the Tip wire of Line 1 (green or white/blue) and the Tip wire of Line 2 (black or white/orange). — Join the Ring wire of Line 1 (red or blue/white) and the Ring wire of Line 2 (yellow or orange/white).
Important Safety Instructions 1. Read and follow all warning notices and instructions marked on the product or included in the manual. 2. This product is intended to be connected to Listed/Certified telephone wiring with a minimum of 24 AWG (.5 mm) behind a Listed/Certified primary protector. 3.
If the Wall Jack Filter causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice is not practical, the telephone company will notify the customer as soon as possible.
Need help?
Do you have a question about the 6040 and is the answer not in the manual?
Questions and answers