Benetech GT5206A Instruction Manual

Digital rcd(elcb)tester

Advertisement

Standard: Q/GMY 028—2020
Version: 5206A-EN-01
DIGITAL RCD(ELCB)TESTER
Instruction Manual
L
E
N
CAT III 300V
+10%
230V
-15%
50Hz
180°
mA
500mA
GT5206A
DIGITAL RCD(ELCB)TESTER
MODEL: GT5206A
LIT=
DO NOT
PROCEED
P-E
LIT=
WIRING
CORRECT
P-N
TEST
PHASE
I n
AUTO
RAMP
X5
X1
1
X
2

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GT5206A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Benetech GT5206A

  • Page 1 MODEL: GT5206A DIGITAL RCD(ELCB)TESTER Instruction Manual LIT= CAT III 300V DO NOT PROCEED +10% 230V -15% LIT= 50Hz WIRING CORRECT TEST 180° PHASE △ AUTO RAMP 500mA GT5206A DIGITAL RCD(ELCB)TESTER Standard: Q/GMY 028—2020 Version: 5206A-EN-01...
  • Page 2: Table Of Contents

    CONTENTS 1. Notice use before Check-up 1. Notice use before Check-up--------------------------------- -------- ---(01) Carefully unpack your kit and ensure that you have the following items. In case that any items is missing or Safety warning ---------------- ------ ------ ------(02) if you find any mismatch or damage, promptly contact Feature and function ------------------------------(05) your dealer.
  • Page 3: Safety Warning

    Safety warning DANGER—indicates that an environment and operation is likely to cause serious or fatal injury. WARNING—Indicates that an environment and operation In order to use this instrument correctly, please read this can cause serious or fatal injury. manual carefully before use. This manual contains CAUTION—Indicates that environment and operation can cause limited injury or damage to the instrument.
  • Page 4 Introduction WARNING ● Due to dangerous voltage in the case during the test, do not open the case of the instrument during the test. If it fails, please have This instrument is controlled by an intelligent it inspected and repaired by qualified personnel. microcontroller chip, with high precision, high reliability ●...
  • Page 5 Name of parts(Figure 1) Functions This instrument is only suitable for single-phase 230V / 50Hz (with power supply voltage range Wiring check: whether three LED indicators are correct, ⑤ ⑥ if two green indicators P-E and P-N are on, and red indicator is not on, then it is correct: the test can only ①...
  • Page 6: Lcd Display

    Specifications 1.1 Measurement range and measurement error (temperature: 23 + 5 ℃;Humidity: 45% ~ 75% RH; altitude≤2000m:) RCD test function: Accuracy Rated operating Functions Operation Fault action current(L n) voltage (AC) time(MAX) Action current Action time Error range: 10/20/30/100/ X1/2 1000ms -10%~+10% 300/500mA...
  • Page 7 the wiring is incorrect; if P and N are upside down or not well grounded, please unplug test leads immediately, check relevant lines, and then connect them after correction until everything is right. CAUTION When E and N wirings are reversed for wiring inspection, leakage switch may trip.
  • Page 8: Other Items

    3.2 Press TEST button 3. Other items No trigger test -------------- The circuit breaker should not be triggered. Trigger test ---------------- The circuit breaker should be triggered. Maintenance and warranty X5 Quick Test ------------- Circuit breaker should be triggered. AUTO RAMP ----------- The circuit breaker should be triggered; with trigger 4.1 Case cleaning: Alcohol, diluent, etc.