Unpacking And Inspecting The Equipment; Installing A Micro Interface Module (Mim) In The Bsx8000-5 - Zhone BSX8000 Installation Instructions Manual

Broadband services switch
Table of Contents

Advertisement

Unpacking and Inspecting the Equipment

If there is any visible damage, do not attempt to connect the device. Contact your
sales or support representative

Installing a Micro Interface Module (MIM) in the BSX8000-5

A MIM provides the upstream network connection for the BLC. Any of Paradyne's
available MIM models may be installed on the BSX8000-5 uplink module.
Procedure
4
HANDLING PRECAUTIONS FOR
!
STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage
due to electrostatic discharge (ESD) during normal operation. When
performing installation procedures, however, take proper static control
precautions to prevent damage to equipment. If you are not sure of the
proper static control precautions, contact your nearest sales or service
representative.
1. Remove the cover plate from the MIM port.
CAUTION: Cover plates should be stored for possible future use. If a MIM is
removed from a BSX8000-5, it must be replaced with either another MIM or a
cover plate. Do not operate a BSX8000-5 with an open MIM port.
2. Carefully slide the faceplate of the MIM into the BSX8000-5 uplink module
faceplate. Ensure that the mounting holes on the MIM are lined up with the
BSX8000-5 uplink module.
3. Secure the MIM circuit board to the BSX8000-5 uplink module with the two
thumbscrews.
June 2005
BSX8-A2-GZ40-20