Gigabyte E143-E30-AAB1 User Manual page 19

Edge server - amd epyc 8004 - 1u up 2-bay gen5 nvme/sata/sas4
Table of Contents

Advertisement

BIOS : AUTH fail
(Note2)
BMC : AUTH fail after doing recovery
BIOS : AUTH fail after doing recovery
Backup Flash Authentication Fail
BMC : AUTH fail
BIOS : AUTH fail
NOTE!
1.
EC FW is broken or not exited result in Microchip CEC1702 cannot load EC FW for authentication.
2
(1) Authentication fail include below scenarios
Configuration table is missing or modified
Public key is missing or modified
Protected area or signature is modified
Flash empty
3.
If active flash is still authentication failed after recovery sequence, Microchip CEC1702 stop the process
and showing LED behavior.
4.
If backup flash authentication is failed cause by configuration table, public key or protected area is
broken. Microchip CEC1702 stop the process and showing LED behavior.
5.
Front panel LED is controlled by BMC or Microchip CEC1702. Once Microchip CEC1702 is working(Auth
or recovery), the front panel LED is controlled by Microchip CEC1702 and vice versa.
(Note3)
(Note3)
(Note4)
System Appearance
- 19 -
Blinks Blue
Blinks Amber
1 time per
1 time per second
second
Blinks Blue
Blinks Green
2 times per
2 times per
second
second
[ON OFF OFF]
[ON OFF OFF]
Blinks Blue
Blinks Amber
2 times per
2 times per
second
second
[ON OFF OFF]
[ON OFF OFF]
Blinks Blue
Blinks Green
2 times per
2 times per
second
second
[ON OFF
[ON OFF
ON OFF]
ON OFF]
Blinks Blue
Blinks Amber
2 times per
2 times per
second
second
[ON OFF
[ON OFF
ON OFF]
ON OFF]

Advertisement

Table of Contents
loading

This manual is also suitable for:

E143-e30-aag1

Table of Contents