AEG OKO FAVORIT 3020i Operating Instructions Manual page 37

Hide thumbs Also See for OKO FAVORIT 3020i:
Table of Contents

Advertisement

Water Discharge
Connection of drain hose:
Maximum permissible height:
1 metre
Minimum height required:
30 cm above the machine's lowest point
In case of extended pipes, which may be laid out to a maximum of 3 metres, the
maximum permissible height for connection of the drain hose is 85 cm.
Warning!
The drain hose should not be kinked or twisted.Take care to install
correctly.
Sink Trap Connection:
The nozzle of the drain hose (dia. 19 mm) is suitable for all types of sink trap
connection. When connecting the drain hose to a sink trap, the internal dia¬
meter must be 15 mm minimum. The drain hose must be attached to the sink
trap connection by means of the accompanying hose clamp.
Water Discharge into Sink:
If you want to run the drain hose on a freestanding machine into a sink, you
should use an attachable hose bend. You can obtain this hose bend from'your
AEG service centre under spare part number ET 646 069 190.
Warning!
Ensure that the hook is securely held in position to avoid accidental
flooding,This can be achieved by attaching the hook to the tap with string.
Drain Hose Extension:
If a longer drain hose is needed, it should be obtained from AEG Spare Parts
Department. The inner diameter of any drain hose extensions must be 19 mm
so that the machine's function is not affected.