DISASSEMBLY- AND RE-ASSEMBLY ADVISE
2.2. Remove the housing.
To remove the housing, start at the back side and undo the clicks on either side of the back plate, next continue on
either the left of right side and undo the click on the long lower side of the housing, next undo the snap on the
front round edge of the housing. Make sure that none of the snaps snap back. Repeat this procedure on the other
side of the appliance, working from back to front. Tip: leave a screwdrive or plastic tool in the area where the fi rst
front click was released, to prevent it snapping back.
3
Remove the housing upwards from the rest of the appliance, but mind fl at cable running through the guide on the
inside of the housing and the water level sensor still connected to the inside of the housing.
You can now access the Boiler and Pump, to remove them, undo the electrical connections and hoses, and reinstall in the
reverse order. Any Ty-wrap that has been removed needs to be replaced by a new one, and tightened with the specifi ed
forces.
3. To replace the PCBA.
3.1. Unscrew the inner frame.
Unscrew the two screws (C, T15) holding the inner frame in place, take special care to note the proper wire
routing, and make sure reinstalling the PCBA will be done in an identical way.