DISASSEMBLY- AND RE-ASSEMBLY ADVISE
Make sure the appliances cordset is disconnected from the mains!
To open the appliance, removal all detachable parts: Water container, driptray and cover, pod holder and collector.
1. To reach the brew chamber.
1.1. Open the top cover.
To open to the top cover the brew chamber needs to be unlocked. Start at the back side of the top cover, using a
plastic tool, and trace along the parting line of the top cover, undoing all the snaps. There are two small snaps on the
front lower side of the brew chamber, undo them with a small fl athead screwdriver (No. 0)
The top cover needs to be tilted forward to be removed. The fl at cable
still attached to the User Interface panel, and can easily be unplugged.
The brew chamber can now be removed by unscrewing the two screws (B, T15), and undoing the hose connection
(g) from the one way valve.
To continue, fi rst remove the two screws (A, T15) from the bottom side of the appliance.
2. To reach internal components like Boiler or Pump.
2.1. Remove the back plate and undo the hose connection (g) from the one way valve (if not done so already).
To remove the back plate, use a plastic tool and trace the parting line of the back plate, undoing all the snaps.
The corrugated tube is still connected to the water container socket, and can easily be pulled off.