ACEUP ENERGY AI2300 Owner's Manual
Hide thumbs Also See for AI2300:

Advertisement

Quick Links

Read the en re instruc on manual carefully and make sure that you fully
understand it before you use the equipment.

Advertisement

Table of Contents
loading

Summary of Contents for ACEUP ENERGY AI2300

  • Page 1 Read the en re instruc on manual carefully and make sure that you fully understand it before you use the equipment.
  • Page 2: Table Of Contents

    Section 1 Introduction and Safety ..................................Introduction ...................... Safety Rules ................Safety Symbols and Meanings ................Exhaust and Location Hazards ....................Electrical Hazards ....................... Fire Hazards ....
  • Page 3: Section 1 Introduction And Safety

    Owner's Manual for Petrol Generator Introduction This unit has been designed to provide DANGER high-performance, efficient operation, and years of use when maintained properly. Indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Consult Manual.
  • Page 4: Exhaust And Location Hazards

    Owner's Manual for Petrol Generator DANGER WARNING Asphyxiation. The exhaust system must be properly Injury and equipment damage. Do not use generator maintained. Do not alter or modify the exhaust system as a step. Doing so could result in falling, damaged as to render it unsafe or make it noncompliant with parts, unsafe equipment operation, and could result local codes and/or standards.
  • Page 5: Electrical Hazards

    Owner's Manual for Petrol Generator Electrical Hazards WARNING DANGER Explosion and fire risk. Do not smoke near unit. Keep fire and spark away. Failure to do so could Electrocution. Contact with bare wires, result in death, serious injury, or property or terminals, and connections while generator equipment damage.
  • Page 6: Section 2 General Information And Setup

    Owner's Manual for Petrol Generator Figure 2-1. Features and Controls Know Your Generator TABLE 1. Generator Components WARNING Recoil Starter Consult Manual. Read and understand manual Fuel Tank Vent completely before using product. Failure to completely understand manual and product Fuel Cap could result in death or serious injury.
  • Page 7 Owner's Manual for Petrol Generator TABLE 2. Product Specifications Generator Specifications AI2300 60 Hz 2300 W 1800 W 120 V AC Output Amperage 15 A Dimensions L x W x H (in/mm) 19.7 x 11.8 x 18.1 (500 x 300 x 460) 20 Kg ** Operating Temperature Range: -13 deg.
  • Page 8: Connection Plugs

    Owner's Manual for Petrol Generator Connection Plugs Economy Switch The economy switch has 2 modes of opera- AC Socket tion: • ON: The quietest mode and best when run- The AC outlet is overload protected by the ning appliances or equipment that are invertor.
  • Page 9: Remove Contents From Carton

    Owner's Manual for Petrol Generator If this occurs, disconnect all electrical loads to NOTE: The generator is shipped without oil in the engine. Add oil slowly and verify oil level determine the cause of the problem before often during filling process to ensure overfilling using the generator again.
  • Page 10: Fuel

    Owner's Manual for Petrol Generator Figure 2-9.Fuel Cap Figure 2-8. Safe Operating Range 4. Turn cap slowly to remove. 7. Remove dipstick and verify oil level is within safe operating range. 5. Slowly add recommended fuel. Do not overfill. NOTE: Verify oil level often during filling pro- 6.
  • Page 11: Section 3 Operation

    Owner's Manual for Petrol Generator Before Starting Engine Grounding the Generator When 1. Verify engine oil level is correct. In Use 2. Verify fuel level is correct. The generator is equipped with an equipment 3. Verify unit is secure on level ground, with ground connecting the generator frame and proper clearance and is in a well ventilated the ground terminals on the AC output recep-...
  • Page 12: Transporting/Tipping Of The Unit

    Owner's Manual for Petrol Generator is provided to assist Wattage Reference Guide Oil Fired Space Heater (30,000 Btu) in determining how many items the generator *Paint Sprayer, Airless (1/3 HP) can operate at one time. NOTE: All figures are approximate. See data Paint Sprayer, Airless (hand-held) label on appliance for wattage requirements.
  • Page 13: Restarting Hot Engines

    Owner's Manual for Petrol Generator 3-2. When engine starts, rotate Figure Low Oil Level Shutdown System OFF/ON/CHOKE dial to ON (2).CHOKE The engine is equipped with a low oil level operation reduced OFF/ON/- sensor that shuts down the engine automati- CHOKE dial is rotated towards ON.
  • Page 14: Parallel Operation

    Owner's Manual for Petrol Generator Parallel Operation For output power up to 3420W, two invert- ers can operate in parallel using Parallel Kit (optional). See the Parallel Kit Operator’s Manual. NOTE: All connections to the parallel kit should be made while both inverters are turned off and all loads disconnected.
  • Page 15: Section 4 Maintenance And Troubleshooting

    Owner's Manual for Petrol Generator Maintenance Preventive Maintenance Regular maintenance will improve perfor- Dirt or debris can cause improper operation mance and extend engine/equipment life. and equipment damage. Clean generator We recommends that all maintenance work daily or before each use. Keep area around be performed by an Independent Autho- and behind muffler free from combustible...
  • Page 16 Owner's Manual for Petrol Generator 7. Replace oil fill cap and hand-tighten. NOTE: Some units have more than one oil fill location. It is only necessary to use one oil fill SAE 30 point. 10W-30 Change Engine Oil Synthetic 5W-30 WARNING Accidental start-up.
  • Page 17 Owner's Manual for Petrol Generator 9. To check oil level, remove funnel and insert dipstick into oil filler neck without screwing it in. See Figure 4-2. 10. Remove dipstick and verify oil level is within safe operating range. NOTE: Verify oil level often during filling pro- cess to ensure overfilling does not occur.
  • Page 18: Storage

    Owner's Manual for Petrol Generator 4. Replace the screens, and retainer, and Prepare Fuel System/Engine for secure with clamp. Storage Fuel stored over 30 days can go bad and damage fuel system components. Keep fuel fresh, use fuel stabilizer. If fuel stabilizer is added to fuel system, pre- pare and run engine for long term storage.
  • Page 19: Troubleshooting

    Owner's Manual for Petrol Generator Troubleshooting PROBLEM CAUSE CORRECTION Engine won't start. 1. Dial turned off. 1. Turn on Dial. 2. Out of fuel. 2. Fill fuel tank. 3. Defective spark plug. 3. Replace spark plug. 4. Plugged fuel filter. 4.